This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system...This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system protection and control. Firstly, the transient behavior is analyzed and the conduction overlap- ping angle γ, is defined. Secondly, seven possible short-circuit current paths induced by different γ values are identified, and the corresponding engineering short-circuit current calculation methods for both AC and DC sides are proposed. And then, the influences of impedance distribution factor κ and equivalent short-circuit resistance Rsc on short-circuit currents are elaborated the proposed analysis methods. Finally, case study is used to verify the effectiveness of展开更多
为揭示直流系统运行方式与变压器直流偏磁现象之间的内在联系,基于宜昌电网的实际参数和PSCAD/EMTDC电磁暂态仿真平台,采用交流系统网络化建模的方法,建立了包含宜昌电网两条500 k V直流输电线路以及接地极临近区域220 k V交流变压器的...为揭示直流系统运行方式与变压器直流偏磁现象之间的内在联系,基于宜昌电网的实际参数和PSCAD/EMTDC电磁暂态仿真平台,采用交流系统网络化建模的方法,建立了包含宜昌电网两条500 k V直流输电线路以及接地极临近区域220 k V交流变压器的直流偏磁电流分布仿真模型。对给定工况下变压器中性点直流电流的分布情况进行了仿真,并与现场实测的数据进行了对比验证,还分别对单接地极场景以及双接地极场景时各个特征变电站主变中性点直流电流分布情况进行仿真,揭示了变压器中性点电位差是决定其直流电流分布特征的根本原因。结果表明:所建立模型的误差在10%以下,具备复现系统实际运行情况的能力。分析结果能够为从系统运行角度抑制直流偏磁提供理论依据。展开更多
文摘This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system protection and control. Firstly, the transient behavior is analyzed and the conduction overlap- ping angle γ, is defined. Secondly, seven possible short-circuit current paths induced by different γ values are identified, and the corresponding engineering short-circuit current calculation methods for both AC and DC sides are proposed. And then, the influences of impedance distribution factor κ and equivalent short-circuit resistance Rsc on short-circuit currents are elaborated the proposed analysis methods. Finally, case study is used to verify the effectiveness of
文摘为揭示直流系统运行方式与变压器直流偏磁现象之间的内在联系,基于宜昌电网的实际参数和PSCAD/EMTDC电磁暂态仿真平台,采用交流系统网络化建模的方法,建立了包含宜昌电网两条500 k V直流输电线路以及接地极临近区域220 k V交流变压器的直流偏磁电流分布仿真模型。对给定工况下变压器中性点直流电流的分布情况进行了仿真,并与现场实测的数据进行了对比验证,还分别对单接地极场景以及双接地极场景时各个特征变电站主变中性点直流电流分布情况进行仿真,揭示了变压器中性点电位差是决定其直流电流分布特征的根本原因。结果表明:所建立模型的误差在10%以下,具备复现系统实际运行情况的能力。分析结果能够为从系统运行角度抑制直流偏磁提供理论依据。