Surface soil heat flux is a component of surface energy budget and its estimation is needed in land-atmosphere interaction studies. This paper develops a new simple method to estimate soil heat flux from soil temperat...Surface soil heat flux is a component of surface energy budget and its estimation is needed in land-atmosphere interaction studies. This paper develops a new simple method to estimate soil heat flux from soil temperature and moisture observations. It give展开更多
Research works on width compensation and correction were carried out in order to eliminate the effects of the PVPC ( plan view pattern control) on width accuracy of plate mill. The thickness correction calculation f...Research works on width compensation and correction were carried out in order to eliminate the effects of the PVPC ( plan view pattern control) on width accuracy of plate mill. The thickness correction calculation formula was derived for compensation the width deviation caused by PVPC function, and the formula is unified under the thinning and thickening conditions. In order to improve the width calculation accuracy, width spread calculation process was modified with dividing one large reduction pass to several small reduction calculation steps. The thickness wedge was simplified to rectangle based on the volume constant principle, and the width spread model for PVPC was constructed. The width compensation and correction for the PVPC functions are used for the online control process, and the Product dimension accuracy is improved. With the decrease of Crop losses, the Droduct yield was increased with 0. 2%.展开更多
Based on the Shougang plat mill project, an on-line dynamic correction algorithm was analyzed. This algorithm can adjust model coefficients better because the reasonable correction is based on the measured and calcula...Based on the Shougang plat mill project, an on-line dynamic correction algorithm was analyzed. This algorithm can adjust model coefficients better because the reasonable correction is based on the measured and calculated rolling force. The results of application on site show that this on-line dynamic correction algorithm is effective.展开更多
BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using tw...BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P<0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P<0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P<0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decre展开更多
基金the Program of One Hundred Talented People of the Chinese Academy of Sciences
文摘Surface soil heat flux is a component of surface energy budget and its estimation is needed in land-atmosphere interaction studies. This paper develops a new simple method to estimate soil heat flux from soil temperature and moisture observations. It give
基金Sponsored by the Fundamental Research Funds for the Central Universities(Grant No.N120407007)
文摘Research works on width compensation and correction were carried out in order to eliminate the effects of the PVPC ( plan view pattern control) on width accuracy of plate mill. The thickness correction calculation formula was derived for compensation the width deviation caused by PVPC function, and the formula is unified under the thinning and thickening conditions. In order to improve the width calculation accuracy, width spread calculation process was modified with dividing one large reduction pass to several small reduction calculation steps. The thickness wedge was simplified to rectangle based on the volume constant principle, and the width spread model for PVPC was constructed. The width compensation and correction for the PVPC functions are used for the online control process, and the Product dimension accuracy is improved. With the decrease of Crop losses, the Droduct yield was increased with 0. 2%.
文摘Based on the Shougang plat mill project, an on-line dynamic correction algorithm was analyzed. This algorithm can adjust model coefficients better because the reasonable correction is based on the measured and calculated rolling force. The results of application on site show that this on-line dynamic correction algorithm is effective.
文摘BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P<0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P<0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P<0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decre