Continuous increase of wind power penetration brings high randomness to power system,and also leads to serious shortage of primary frequency regulation(PFR)reserve for power system whose reserve capacity is typically ...Continuous increase of wind power penetration brings high randomness to power system,and also leads to serious shortage of primary frequency regulation(PFR)reserve for power system whose reserve capacity is typically provided by conventional units.Considering large-scale wind power participating in PFR,this paper proposes a unit commitment optimization model with respect to coordination of steady state and transient state.In addition to traditional operation costs,losses of wind farm de-loaded operation,environmental benefits and transient frequency safety costs in high-risk stochastic scenarios are also considered in the model.Besides,the model makes full use of interruptible loads on demand side as one of the PFR reserve sources.A selection method for high-risk scenarios is also proposed to improve the calculation efficiency.Finally,this paper proposes an inner-outer iterative optimization method for the model solution.The method is validated by the New England 10-machine system,and the results show that the optimization model can guarantee both the safety of transient frequency and the economy of system operation.展开更多
Heavy renewable penetrations and high-voltage cross-regional transmission systems reduce the inertia and critical frequency stability of power systems after disturbances.Therefore,the power system operators should ens...Heavy renewable penetrations and high-voltage cross-regional transmission systems reduce the inertia and critical frequency stability of power systems after disturbances.Therefore,the power system operators should ensure the frequency nadirs after possible disturbances are within the set restriction,e.g.,0.20 Hz.Traditional methods utilize linearized and simplified control models to quantify the frequency nadirs and achieve frequency-constrained unit commitments(FCUCs).However,the simplified models are hard to depict the frequency responses of practical units after disturbances.Also,they usually neglect the regulations from battery storage.This paper achieves FCUCs with linear rules extracted from massive simulation results.We simulate the frequency responses on typical thermal-hydro-storage systems under diverse unit online conditions.Then,we extract the rules of frequency nadirs after disturbances merely with linear support vector machine to evaluate the frequency stability of power systems.The algorithm holds a high accuracy in a wide range of frequency restrictions.Finally,we apply the rules to three typical cases to show the influences of frequency constraints on unit commitments.展开更多
基金supported by the Six Talent Peaks Project in Jiangsu Province(No.XNY-020)the State Key Laboratory of Smart Grid Protection and Control
文摘Continuous increase of wind power penetration brings high randomness to power system,and also leads to serious shortage of primary frequency regulation(PFR)reserve for power system whose reserve capacity is typically provided by conventional units.Considering large-scale wind power participating in PFR,this paper proposes a unit commitment optimization model with respect to coordination of steady state and transient state.In addition to traditional operation costs,losses of wind farm de-loaded operation,environmental benefits and transient frequency safety costs in high-risk stochastic scenarios are also considered in the model.Besides,the model makes full use of interruptible loads on demand side as one of the PFR reserve sources.A selection method for high-risk scenarios is also proposed to improve the calculation efficiency.Finally,this paper proposes an inner-outer iterative optimization method for the model solution.The method is validated by the New England 10-machine system,and the results show that the optimization model can guarantee both the safety of transient frequency and the economy of system operation.
基金supported by the research project from China Three Gorges Corporation(No.202103386).
文摘Heavy renewable penetrations and high-voltage cross-regional transmission systems reduce the inertia and critical frequency stability of power systems after disturbances.Therefore,the power system operators should ensure the frequency nadirs after possible disturbances are within the set restriction,e.g.,0.20 Hz.Traditional methods utilize linearized and simplified control models to quantify the frequency nadirs and achieve frequency-constrained unit commitments(FCUCs).However,the simplified models are hard to depict the frequency responses of practical units after disturbances.Also,they usually neglect the regulations from battery storage.This paper achieves FCUCs with linear rules extracted from massive simulation results.We simulate the frequency responses on typical thermal-hydro-storage systems under diverse unit online conditions.Then,we extract the rules of frequency nadirs after disturbances merely with linear support vector machine to evaluate the frequency stability of power systems.The algorithm holds a high accuracy in a wide range of frequency restrictions.Finally,we apply the rules to three typical cases to show the influences of frequency constraints on unit commitments.