The whole cold-chain for exporting sweet potato(native variety“Abees”),to foreign market included immediate curing operation directly after harvest helped in healing skin texture,however,in order to reduce postharve...The whole cold-chain for exporting sweet potato(native variety“Abees”),to foreign market included immediate curing operation directly after harvest helped in healing skin texture,however,in order to reduce postharvest soft rot(Rhizopus stolonifer)incidence following trimming,and washing,ultraviolet light(UV-C)treatment was used as a main sanitizer for eliminating the soft rot.Exposure of the roots to UV-C(254 nm)was applied in a UV-C room on freshly harvested and cured sweet potato while rolling up on a movable line at 20 cm distance for 1,2,and 3 hr.As combining UV-C treatment with chlorine(200 ppm)on roots,marked and significant reduction of the total microbial load and Rhizopus potential was achieved on root surfaces respectively compared with chlorine alone.It also reduced soft rot percentage to almost 0%infection.After 3 months of cold-storage,quality assessment of sweet potato showed that root characteristics were markedly maintained.The ability of UV-C light to induce phenylalanine ammonia lyase(PAL)enzyme activity in root tissue and maintain the activities of peroxidase and polyphenol oxidase,however with slight increase,was detected.UV-C caused an increase of phenol content in sweet potato tissue that made an activation of defense reaction against the rot causal pathogen.As the exposure time to UV-C light increased,a higher content of phenols occurred.Moreover,UV-C application caused decrease in sugar content of root tissue that is flavored by soft rot-causal pathogen.展开更多
Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of col...Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.展开更多
文摘The whole cold-chain for exporting sweet potato(native variety“Abees”),to foreign market included immediate curing operation directly after harvest helped in healing skin texture,however,in order to reduce postharvest soft rot(Rhizopus stolonifer)incidence following trimming,and washing,ultraviolet light(UV-C)treatment was used as a main sanitizer for eliminating the soft rot.Exposure of the roots to UV-C(254 nm)was applied in a UV-C room on freshly harvested and cured sweet potato while rolling up on a movable line at 20 cm distance for 1,2,and 3 hr.As combining UV-C treatment with chlorine(200 ppm)on roots,marked and significant reduction of the total microbial load and Rhizopus potential was achieved on root surfaces respectively compared with chlorine alone.It also reduced soft rot percentage to almost 0%infection.After 3 months of cold-storage,quality assessment of sweet potato showed that root characteristics were markedly maintained.The ability of UV-C light to induce phenylalanine ammonia lyase(PAL)enzyme activity in root tissue and maintain the activities of peroxidase and polyphenol oxidase,however with slight increase,was detected.UV-C caused an increase of phenol content in sweet potato tissue that made an activation of defense reaction against the rot causal pathogen.As the exposure time to UV-C light increased,a higher content of phenols occurred.Moreover,UV-C application caused decrease in sugar content of root tissue that is flavored by soft rot-causal pathogen.
基金funded by the‘Research Project of the Sucheng to Sihong Section of the Yanluo Expressway-Measurement Technology and Application of Bridge Quality Project Based on UAV Binocular Imaging(No.00-00-JSFW-20230203-029)’,received by H.Z.Wang.
文摘Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.