Combining improved injector, gas line and valve-driving models, a gas chromatograph (GC) equipped with Hydrogen Flame Ionization Detector (FID) and Electron Capture Detector (ECD), can measure CH4, CO2, and N2O simult...Combining improved injector, gas line and valve-driving models, a gas chromatograph (GC) equipped with Hydrogen Flame Ionization Detector (FID) and Electron Capture Detector (ECD), can measure CH4, CO2, and N2O simultaneously in an air sample in four minutes. Test results show that the system has high sensitivity, resolution, and precision; the linear response range of the system meets the requirement of flux measurements in situ. The system is suitable for monitoring fluxes of the main greenhouse gases in a short-plant field since it is easy to use, efficacious, and constant and reliable in collecting data.展开更多
AIM: To perform plasma free amino acid (PFAA) profiling of esophageal squamous cell carcinoma (ESCC) patients at different pathological stages and healthy subjects.
Rapid on-site identification of volatile organic compounds (VOCs) in ambient air is an important first step in remediation efforts. This study describes modification of a commercially available, portable GC/MS syste...Rapid on-site identification of volatile organic compounds (VOCs) in ambient air is an important first step in remediation efforts. This study describes modification of a commercially available, portable GC/MS system and development of an analysis protocol for rapid (〈 3 min) sampling and identification of VOCs typically found at contaminated sites at the low ppbv level.展开更多
With high performance liquid chromatography, the concentrations of α-endosulfan, DDE, parathion methyl, isoproturon, atrazine, carbaryl and carbofuran were determined in farmed raised fish Labeo rohita of two weight ...With high performance liquid chromatography, the concentrations of α-endosulfan, DDE, parathion methyl, isoproturon, atrazine, carbaryl and carbofuran were determined in farmed raised fish Labeo rohita of two weight groups. All these pesticide residues were detected in fish meat samples. All these pesticide residues except isoproturon were identified in soil sediments, whereas all these pesticide residues except isoproturon, carbaryl and DDE were also present in water samples. DDT, heptachlor, β-endosulfan, chlorpyrifos, dimethoate, captan, cypermethrin, chlorobromuron and chlorotoluron were absent in all samples of water, sediments and fish flesh. The pesticide residues levels were in order of parathion methyl 〉 DDE 〉 carbofuran 〉 atrazine 〉 α-endosulfan 〉 isoproturan 〉 carbaryl. The concentrations of pesticides were higher in fish weighing 800 -1 300 g than in those weighing 250 -750 g. The DDE was remained highest in sediments, while that was not detected in water samples. The pesticides (endosulfan, parathion methyl, atrazine and carbofuran) had crossed their MRL values (0.001 μg/g) in water samples.展开更多
A simple size-exclusion high-performance liquid chromatographic method was developed for rapid molecular mass screening to determine the average molecular mass, polydispersity, and quantity of Taizishen polysaccharide...A simple size-exclusion high-performance liquid chromatographic method was developed for rapid molecular mass screening to determine the average molecular mass, polydispersity, and quantity of Taizishen polysaccharides extract. The screening used a TOSOH TSK-GEL G3000SW high-performance liquid chromatographic column with 0.1 mol/L NaNO3 buffer as the mobile phase and refractive index detector. The molecular mass calibration curve was linear for polysaccharide standards from 10 to 100 kDa with a correlation coefficient of 0.9991. The method can be used to analyze the quantity, average molecular mass, and polydispersity of polysaccharides. In addition, the screening method is suitable for quality control of polysaccharide preparations in Chinese medicines and pharmaceutical products.展开更多
In order to suppress the harm of gas explosion,the current study researched on the body of vacuum chamber.The previous studies verifed that it could obviously lower the explosion overpressure by reasonably arranging v...In order to suppress the harm of gas explosion,the current study researched on the body of vacuum chamber.The previous studies verifed that it could obviously lower the explosion overpressure by reasonably arranging vacuum chamber on pipe.That is to say,the vacuum chamber has the effect of absorbing wave and energy.To further deeply analyze the vacuum chamber suppressing gas explosion,this research designed the L-type pipe of gas explosion,and compared the experimental results of gas explosion with vacuum chamber and without vacuum chamber.Besides,using the gas chromatograph,this study also investigated the gas compositions in the pipe before and after explosion.The results show that:(1)without vacuum chamber,the maximum value of explosion overpressure is 0.22 MPa,with60 ms duration,and after explosion,the concentration of oxygen drops to 12.07%,but the concentration of carbon monoxide increases to 4392.3 10à6,and the concentration of carbon dioxide goes up to7.848%,which can make the persons in danger suffocate and die;(2)with vacuum chamber,explosion overpressure drops to 0.18 MPa,with 20 ms duration or less,and after explosion,the concentration of oxygen still remains 12.07%,but the concentration of methane is 7.83%,however the concentration of carbon monoxide is only 727.24 10à6,and the concentration of carbon dioxide is only 1.219%,at the this moment the concentration ratio of toxic gas drops by more than 83%in comparison to be that without vacuum chamber.Consequently,the vacuum chamber can guarantee that most methane does not take part in chemical reaction,and timely quenches the deflagration reaction of gas and oxygen.Because of the two points mentioned above,it reduces the explosion energy,and lowers that the overpressure of blast wave impacts and damages on the persons and facilities,and also decreases the consumption of oxygen and the production of the toxic gas.Therefore,it is safe to conclude that the vacuum chamber not only absorbs wave and energy,but also prevents and suppresses explosion.展开更多
Objective Many studies have been conducted in order to evaluate the genotoxicity of chemicals and waste materials, which utilized in vivo test protocols. The use of animals for routine toxicity testing is now question...Objective Many studies have been conducted in order to evaluate the genotoxicity of chemicals and waste materials, which utilized in vivo test protocols. The use of animals for routine toxicity testing is now questioned by a growing segment of society. Methods Keeping the above fact in mind, we have conducted in the present study the genotoxicity evaluation of oily sludge samples generated from a petroleum refinery and petrochemical industry and ETP sludge from petroleum refinery using DNA damage, chromosomal aberration, p53 protein induction and apoptosis in short term in vitro mammalian Chinese Hamster Ovary cell cultures. Results It is evident from the results that the oily sludge compounds derived from petroleum refinery and petrochemical industry could cause DNA damage, chromosomal aberration, p53 protein accumulation and apoptotic cell death on exposure to oily sludge extracts in the presence of metabolic activation system (S-9 mix), however, ETP sludge extract could not cause significant genotoxicity in comparison to oily sludge extract and negative control. Conclusion The effect may be attributed to polycyclic aromatic hydrocarbons present in the samples as evidenced from GC-MS.展开更多
文摘Combining improved injector, gas line and valve-driving models, a gas chromatograph (GC) equipped with Hydrogen Flame Ionization Detector (FID) and Electron Capture Detector (ECD), can measure CH4, CO2, and N2O simultaneously in an air sample in four minutes. Test results show that the system has high sensitivity, resolution, and precision; the linear response range of the system meets the requirement of flux measurements in situ. The system is suitable for monitoring fluxes of the main greenhouse gases in a short-plant field since it is easy to use, efficacious, and constant and reliable in collecting data.
基金Supported by National Natural Science Foundation of China,Grant No.81360356Scientific Research Foundation of Xinjiang Medical University,Grant No.XJC201221
文摘AIM: To perform plasma free amino acid (PFAA) profiling of esophageal squamous cell carcinoma (ESCC) patients at different pathological stages and healthy subjects.
基金supported by a grant from the Syracuse Center of Excellence
文摘Rapid on-site identification of volatile organic compounds (VOCs) in ambient air is an important first step in remediation efforts. This study describes modification of a commercially available, portable GC/MS system and development of an analysis protocol for rapid (〈 3 min) sampling and identification of VOCs typically found at contaminated sites at the low ppbv level.
文摘With high performance liquid chromatography, the concentrations of α-endosulfan, DDE, parathion methyl, isoproturon, atrazine, carbaryl and carbofuran were determined in farmed raised fish Labeo rohita of two weight groups. All these pesticide residues were detected in fish meat samples. All these pesticide residues except isoproturon were identified in soil sediments, whereas all these pesticide residues except isoproturon, carbaryl and DDE were also present in water samples. DDT, heptachlor, β-endosulfan, chlorpyrifos, dimethoate, captan, cypermethrin, chlorobromuron and chlorotoluron were absent in all samples of water, sediments and fish flesh. The pesticide residues levels were in order of parathion methyl 〉 DDE 〉 carbofuran 〉 atrazine 〉 α-endosulfan 〉 isoproturan 〉 carbaryl. The concentrations of pesticides were higher in fish weighing 800 -1 300 g than in those weighing 250 -750 g. The DDE was remained highest in sediments, while that was not detected in water samples. The pesticides (endosulfan, parathion methyl, atrazine and carbofuran) had crossed their MRL values (0.001 μg/g) in water samples.
文摘A simple size-exclusion high-performance liquid chromatographic method was developed for rapid molecular mass screening to determine the average molecular mass, polydispersity, and quantity of Taizishen polysaccharides extract. The screening used a TOSOH TSK-GEL G3000SW high-performance liquid chromatographic column with 0.1 mol/L NaNO3 buffer as the mobile phase and refractive index detector. The molecular mass calibration curve was linear for polysaccharide standards from 10 to 100 kDa with a correlation coefficient of 0.9991. The method can be used to analyze the quantity, average molecular mass, and polydispersity of polysaccharides. In addition, the screening method is suitable for quality control of polysaccharide preparations in Chinese medicines and pharmaceutical products.
基金Financial support from the State Key Laboratory Cultivation Base for Gas Geology and Gas Control of Henan Polytechnic University of China(No.WS2012A04)
文摘In order to suppress the harm of gas explosion,the current study researched on the body of vacuum chamber.The previous studies verifed that it could obviously lower the explosion overpressure by reasonably arranging vacuum chamber on pipe.That is to say,the vacuum chamber has the effect of absorbing wave and energy.To further deeply analyze the vacuum chamber suppressing gas explosion,this research designed the L-type pipe of gas explosion,and compared the experimental results of gas explosion with vacuum chamber and without vacuum chamber.Besides,using the gas chromatograph,this study also investigated the gas compositions in the pipe before and after explosion.The results show that:(1)without vacuum chamber,the maximum value of explosion overpressure is 0.22 MPa,with60 ms duration,and after explosion,the concentration of oxygen drops to 12.07%,but the concentration of carbon monoxide increases to 4392.3 10à6,and the concentration of carbon dioxide goes up to7.848%,which can make the persons in danger suffocate and die;(2)with vacuum chamber,explosion overpressure drops to 0.18 MPa,with 20 ms duration or less,and after explosion,the concentration of oxygen still remains 12.07%,but the concentration of methane is 7.83%,however the concentration of carbon monoxide is only 727.24 10à6,and the concentration of carbon dioxide is only 1.219%,at the this moment the concentration ratio of toxic gas drops by more than 83%in comparison to be that without vacuum chamber.Consequently,the vacuum chamber can guarantee that most methane does not take part in chemical reaction,and timely quenches the deflagration reaction of gas and oxygen.Because of the two points mentioned above,it reduces the explosion energy,and lowers that the overpressure of blast wave impacts and damages on the persons and facilities,and also decreases the consumption of oxygen and the production of the toxic gas.Therefore,it is safe to conclude that the vacuum chamber not only absorbs wave and energy,but also prevents and suppresses explosion.
文摘Objective Many studies have been conducted in order to evaluate the genotoxicity of chemicals and waste materials, which utilized in vivo test protocols. The use of animals for routine toxicity testing is now questioned by a growing segment of society. Methods Keeping the above fact in mind, we have conducted in the present study the genotoxicity evaluation of oily sludge samples generated from a petroleum refinery and petrochemical industry and ETP sludge from petroleum refinery using DNA damage, chromosomal aberration, p53 protein induction and apoptosis in short term in vitro mammalian Chinese Hamster Ovary cell cultures. Results It is evident from the results that the oily sludge compounds derived from petroleum refinery and petrochemical industry could cause DNA damage, chromosomal aberration, p53 protein accumulation and apoptotic cell death on exposure to oily sludge extracts in the presence of metabolic activation system (S-9 mix), however, ETP sludge extract could not cause significant genotoxicity in comparison to oily sludge extract and negative control. Conclusion The effect may be attributed to polycyclic aromatic hydrocarbons present in the samples as evidenced from GC-MS.