The finite element method is first introduced into the design process of detecting electrodes of three electrode capacitance fuze, the mutual capacitance of the fuze and target is calculated by the finite element met...The finite element method is first introduced into the design process of detecting electrodes of three electrode capacitance fuze, the mutual capacitance of the fuze and target is calculated by the finite element method, which provides the parameters for simulation circuit and design of detecting electrode. The finite element method pierces the traditional method of designing detecting electrode-design, test and adjustment. The system capacitance can be calculated accurately and the performance can be predicted in the design period of the detecting electrode, which saves a lot of research fee. The capacitances of a mortar shell fuze above ground 2 m and lower are given. After putting the computing data into simulating circuit, the demodulation voltage can be obtained, its changing trend is in agreement with the tested result.展开更多
For establishing the equation of the capacitive target detection accurately, the distributing characteristics of the charges on the bomb body with capacitance fuze were explored. Continuous charges were analyzed disp...For establishing the equation of the capacitive target detection accurately, the distributing characteristics of the charges on the bomb body with capacitance fuze were explored. Continuous charges were analyzed dispersively. Based on the Coulomb's law, the dynamic equilibrium equations of the inducing charges on the bomb body were set up. For the four cases of d 0/L (the ratio between the electrode distance and the bomb length), the curves of the charge's distribution were given. It was concluded that: ① the charge density decreases steadily from the end near the frontal electrode to the bomb tail; ② the declining rate of the density is governed by d 0/L , the larger the value of d 0/L ,the higher the declining rate, and vice versa.展开更多
For a detector in a capacitanee fuze working in an electrostatic field, the bomblength (effective length of the conductor part) is an important factor affecting the sensitivityof detection. For the two different kinds...For a detector in a capacitanee fuze working in an electrostatic field, the bomblength (effective length of the conductor part) is an important factor affecting the sensitivityof detection. For the two different kinds of detecting circuit models in general use (the frequency-sensitive and the amplitude-coupling ), mechanism of the effect of bomblength on the sensitvity of detection is analyzed. Through the analysis a conclusion in fullagreement with experimental results has been drawn, that is. the longer the bomb length,the higher the sensitivity, on the condition that the sizes and the sites of the detecting electrodes and bomb diameter remain unchanged.展开更多
In view of drastic possible changes in fuze environment tempera- ture,a kind of temperature autocompensated detecting circuit for the capaci- tance fuze is proposed.It provides a steady detected output when the envi- ...In view of drastic possible changes in fuze environment tempera- ture,a kind of temperature autocompensated detecting circuit for the capaci- tance fuze is proposed.It provides a steady detected output when the envi- ronment temperature varies from-50℃ to 65℃ and keeps a stable detecting sensitivity.Based on an analysis of the circuit,influence of the major param- eters of the oscillating circuit on the amplitude are explored.A few impor- tant controllable parameters affecting the circuit feature are found out.A parameter-control method is given in order to improve the circuit perfor- mance.展开更多
文摘The finite element method is first introduced into the design process of detecting electrodes of three electrode capacitance fuze, the mutual capacitance of the fuze and target is calculated by the finite element method, which provides the parameters for simulation circuit and design of detecting electrode. The finite element method pierces the traditional method of designing detecting electrode-design, test and adjustment. The system capacitance can be calculated accurately and the performance can be predicted in the design period of the detecting electrode, which saves a lot of research fee. The capacitances of a mortar shell fuze above ground 2 m and lower are given. After putting the computing data into simulating circuit, the demodulation voltage can be obtained, its changing trend is in agreement with the tested result.
文摘For establishing the equation of the capacitive target detection accurately, the distributing characteristics of the charges on the bomb body with capacitance fuze were explored. Continuous charges were analyzed dispersively. Based on the Coulomb's law, the dynamic equilibrium equations of the inducing charges on the bomb body were set up. For the four cases of d 0/L (the ratio between the electrode distance and the bomb length), the curves of the charge's distribution were given. It was concluded that: ① the charge density decreases steadily from the end near the frontal electrode to the bomb tail; ② the declining rate of the density is governed by d 0/L , the larger the value of d 0/L ,the higher the declining rate, and vice versa.
文摘For a detector in a capacitanee fuze working in an electrostatic field, the bomblength (effective length of the conductor part) is an important factor affecting the sensitivityof detection. For the two different kinds of detecting circuit models in general use (the frequency-sensitive and the amplitude-coupling ), mechanism of the effect of bomblength on the sensitvity of detection is analyzed. Through the analysis a conclusion in fullagreement with experimental results has been drawn, that is. the longer the bomb length,the higher the sensitivity, on the condition that the sizes and the sites of the detecting electrodes and bomb diameter remain unchanged.
文摘In view of drastic possible changes in fuze environment tempera- ture,a kind of temperature autocompensated detecting circuit for the capaci- tance fuze is proposed.It provides a steady detected output when the envi- ronment temperature varies from-50℃ to 65℃ and keeps a stable detecting sensitivity.Based on an analysis of the circuit,influence of the major param- eters of the oscillating circuit on the amplitude are explored.A few impor- tant controllable parameters affecting the circuit feature are found out.A parameter-control method is given in order to improve the circuit perfor- mance.