The existing LCC-HVDC transmission project adopts the fixed-time delay restarting method.This method has disadvantages such as non-selectivity,long restart process,and high probability of restart failure.These issues ...The existing LCC-HVDC transmission project adopts the fixed-time delay restarting method.This method has disadvantages such as non-selectivity,long restart process,and high probability of restart failure.These issues cause a secondary impact on equipment and system power fluctuation.To solve this problem,an adaptive restarting method based on the principle of fault location by current injection is proposed.First,an additional control strategy is proposed to inject a current detection signal.Second,the propagation law of the current signal in the line is analyzed based on the distributed parameter model of transmission line.Finally,a method for identifying fault properties based on the principle of fault location is proposed.The method fully considers the influence of the long-distance transmission line with earth capacitance and overcomes the influence of the increasing effect of the opposite terminal.Simulation results show that the proposed method can accurately identify the fault properties under various complex fault conditions and subsequently realize the adaptive restarting process.展开更多
The trimmed mean is one of the most common estimators of location for symmetrical distributions, whose effect depends on whether the trim rate matches the proportion of contaminated data. Based on the geometric charac...The trimmed mean is one of the most common estimators of location for symmetrical distributions, whose effect depends on whether the trim rate matches the proportion of contaminated data. Based on the geometric characteristics of the curve of the trimmed variance function, the authors propose two kinds of adaptive trimmed mean algorithms. The accuracy of the estimators is compared with that of other often-used estimates, such as sample mean, trimmed mean, trimean, and median, by means of simulation method. The results show that the accuracy of the adaptive derivative optimization trimmed mean method is close to the optimum performance in case of medium contamination (the contamination rate is less than 50%). Under high contamination situation (the contamination rate equals 8070), the performance of the estimates is comparable to that of the median and is superior to other counterparts.展开更多
基金the National Natural Science Foundation of China(Nos.61473069 and 61374124)the Natural Science Foundation of Liaoning Province(No.2013020043)the Fundamental Research Funds for the Central Universities of China(Nos.N140405002 and N130104001)
基金supported by Science and Technology Project of State Grid Corporation of China(52094020006U)National Natural Science Foundation of China(NSFC)(52061635105)China Postdoctoral Science Foundation(2021M692525).
文摘The existing LCC-HVDC transmission project adopts the fixed-time delay restarting method.This method has disadvantages such as non-selectivity,long restart process,and high probability of restart failure.These issues cause a secondary impact on equipment and system power fluctuation.To solve this problem,an adaptive restarting method based on the principle of fault location by current injection is proposed.First,an additional control strategy is proposed to inject a current detection signal.Second,the propagation law of the current signal in the line is analyzed based on the distributed parameter model of transmission line.Finally,a method for identifying fault properties based on the principle of fault location is proposed.The method fully considers the influence of the long-distance transmission line with earth capacitance and overcomes the influence of the increasing effect of the opposite terminal.Simulation results show that the proposed method can accurately identify the fault properties under various complex fault conditions and subsequently realize the adaptive restarting process.
基金supported in part by the National Basic Research Program of China under Grant No. 2010CB950703the Natural Science Foundation of China under Grant No.10901020the Fundamental Research Funds for the Central Universities
文摘The trimmed mean is one of the most common estimators of location for symmetrical distributions, whose effect depends on whether the trim rate matches the proportion of contaminated data. Based on the geometric characteristics of the curve of the trimmed variance function, the authors propose two kinds of adaptive trimmed mean algorithms. The accuracy of the estimators is compared with that of other often-used estimates, such as sample mean, trimmed mean, trimean, and median, by means of simulation method. The results show that the accuracy of the adaptive derivative optimization trimmed mean method is close to the optimum performance in case of medium contamination (the contamination rate is less than 50%). Under high contamination situation (the contamination rate equals 8070), the performance of the estimates is comparable to that of the median and is superior to other counterparts.