Axial flow pump is a kind of typical pumps with rotor-stator interaction, thus the measurement of the flow field between impeller and guide vane would facilitate the study of the internal rotor-stator interaction mech...Axial flow pump is a kind of typical pumps with rotor-stator interaction, thus the measurement of the flow field between impeller and guide vane would facilitate the study of the internal rotor-stator interaction mechanism. Through a structural modification of a traditional axial flow pump, the requirements of particle image velocimetry(PIV) measurement are met. Under the condition of opt.0.8Q, the axial vortex is identified between impeller hub and guide vane hub, which is developed into the main flow and to affect the movement when the relative positions of impeller and guide vane at different flow rates are the same. Besides, the development and the dissipation of the tip leakage and the passage vortex in impeller passages are mainly responsible for the difference of the flow field close to the outer rim. As the flow rate decreases, the distribution of the meridional velocities at the impeller outlet becomes more non-uniform and the radial velocity component keeps increasing. The PIV measurement results under the condition of opt.1.0Q indicate that the flow separation and the trailing vortex at the trailing edge of a blade are likely to result in a velocity sudden change in this area, which would dramatically destroy the continuity of the flow field. Moreover, the radial direction of the flow between impeller and guide vane on the measurement plane does not always point from hub to rim. For a certain position, the direction is just from rim to hub, as is affected by the location of the intersection line of the shooting section and the impeller blade on the impeller as well as the angle between the intersection line and the rotating shaft.展开更多
The tip leakage flow between a blade and a casing wall has a strong impact on compressor pressure rise capability, efficiency, and stability. Consequently, there is a strong motivation to look for means to minimize it...The tip leakage flow between a blade and a casing wall has a strong impact on compressor pressure rise capability, efficiency, and stability. Consequently, there is a strong motivation to look for means to minimize its impact on performance. This paper presents the potential of passive tip leakage flow control to increase the aerodynamic performance of highly loaded compressor blades. Experimental investigations on a linear compressor cascade equipped with blade winglets mounted to the blade tips have been carried out. Results for a variation of the tip clearance and the winglet geometry are presented. Current results indicate that the use of proper tip winglets in a compressor cascade can positively affect the local aerodynamic field by weakening the tip leakage vortex. Results also show that the suction-side winglets are aerodynamically superior to the pressure-side or combined winglets. The suction-side winglets are capable of reducing the exit total pressure loss associated with the tip leakage flow and the passage secondary flow to a significant degree.展开更多
基金Project supported by the National Twelfth Five-year Supporting Plan of China(Grant No.2011BAF14B01)the Priority Academic Program Development of Jiangsu Higher Education InstitutionsGraduate innovation program of Jiangsu Province(Grant No.CXLX12_0643)
文摘Axial flow pump is a kind of typical pumps with rotor-stator interaction, thus the measurement of the flow field between impeller and guide vane would facilitate the study of the internal rotor-stator interaction mechanism. Through a structural modification of a traditional axial flow pump, the requirements of particle image velocimetry(PIV) measurement are met. Under the condition of opt.0.8Q, the axial vortex is identified between impeller hub and guide vane hub, which is developed into the main flow and to affect the movement when the relative positions of impeller and guide vane at different flow rates are the same. Besides, the development and the dissipation of the tip leakage and the passage vortex in impeller passages are mainly responsible for the difference of the flow field close to the outer rim. As the flow rate decreases, the distribution of the meridional velocities at the impeller outlet becomes more non-uniform and the radial velocity component keeps increasing. The PIV measurement results under the condition of opt.1.0Q indicate that the flow separation and the trailing vortex at the trailing edge of a blade are likely to result in a velocity sudden change in this area, which would dramatically destroy the continuity of the flow field. Moreover, the radial direction of the flow between impeller and guide vane on the measurement plane does not always point from hub to rim. For a certain position, the direction is just from rim to hub, as is affected by the location of the intersection line of the shooting section and the impeller blade on the impeller as well as the angle between the intersection line and the rotating shaft.
基金the National Natural Science Foundation of China(Grant No.:51076018)the Fundamental Research Funds for the Central UniversitiesSpecialized Research Fund for the Doctoral Program of Higher Education
文摘The tip leakage flow between a blade and a casing wall has a strong impact on compressor pressure rise capability, efficiency, and stability. Consequently, there is a strong motivation to look for means to minimize its impact on performance. This paper presents the potential of passive tip leakage flow control to increase the aerodynamic performance of highly loaded compressor blades. Experimental investigations on a linear compressor cascade equipped with blade winglets mounted to the blade tips have been carried out. Results for a variation of the tip clearance and the winglet geometry are presented. Current results indicate that the use of proper tip winglets in a compressor cascade can positively affect the local aerodynamic field by weakening the tip leakage vortex. Results also show that the suction-side winglets are aerodynamically superior to the pressure-side or combined winglets. The suction-side winglets are capable of reducing the exit total pressure loss associated with the tip leakage flow and the passage secondary flow to a significant degree.