The four electrodes in the stripline beam position monitor(BPM) for Hefei Light Source(HLS II) storage ring are of axially symmetric type. We have derived a new calibration method of electrode gains for this type stri...The four electrodes in the stripline beam position monitor(BPM) for Hefei Light Source(HLS II) storage ring are of axially symmetric type. We have derived a new calibration method of electrode gains for this type stripline BPM. The gain fit error of different data grids was analyzed, and the ±5 mm by ±5 mm grid is the best.The electrode gains of two stripline BPMs(HLS II SR-BD-STLB1 and HLS II SR-BD-STLB2) were obtained based on offline calibrated data. The results show that data after fitting gains are improved, with the electrode gains being between 0.94 and 1.15.展开更多
基金Supported by the Natural Science Foundation of China(Nos.11175173,11375178 and 11005105)
文摘The four electrodes in the stripline beam position monitor(BPM) for Hefei Light Source(HLS II) storage ring are of axially symmetric type. We have derived a new calibration method of electrode gains for this type stripline BPM. The gain fit error of different data grids was analyzed, and the ±5 mm by ±5 mm grid is the best.The electrode gains of two stripline BPMs(HLS II SR-BD-STLB1 and HLS II SR-BD-STLB2) were obtained based on offline calibrated data. The results show that data after fitting gains are improved, with the electrode gains being between 0.94 and 1.15.