Objective The aim of the study was to compare the efficacy and safety of whole brain radiotherapy(WBRT) used alone and combined with stereotactic radiosurgery(SRS) in the treatment of limited(1–4)brain metastases. Me...Objective The aim of the study was to compare the efficacy and safety of whole brain radiotherapy(WBRT) used alone and combined with stereotactic radiosurgery(SRS) in the treatment of limited(1–4)brain metastases. Methods We searched for randomized controlled and matched-pair analysis trials comparing WBRT plus SRS versus WBRT alone for brain metastases. The primary outcomes were the overall survival(OS), intracranial control(IC), and localcontrol(LC). The secondary outcome was radiation toxicity. The log hazard ratios(lnHRs) and their variances were extracted from published Kaplan-Meier curves and pooled using the generic inverse variance method in the RevMan 5.3 software. The non-pooled outcome measures were evaluated using descriptive analysis. Results Three randomized controlled trials and two matched-pair analysis studies were included. There was no difference in the OS for limited brain metastases between the two groups [lnHR 0.91(95% CI 0.76–1.09, P = 0.32) vs. 0.72(95% CI 0.44–1.19, P = 0.20)]. The LC and IC were significantly higher in the combined treatment group [lnHR 0.69(95% CI 0.55–0.86, P = 0.001) vs. 0.41(95% CI 0.29–0.58, P < 0.0001)]. For patients with a single lesion, one trial showed a higher survival in the combined treatment group(median OS: 6.5 months vs. 4.9 months, P = 0.04). The combined treatment was not associated with significantly higher incidence of radiation toxicity. Conclusion Combined treatment with WBRT plus SRS should be recommended for patients with limited brain metastases based on the better LC and IC without increased toxicity. It should also be considered a routine treatment option for patients with solitary brain metastases based on the prolonged OS.展开更多
<strong>Purpose:</strong> The purpose of this study is to provide technical information on commissioning the TrueBeam STx 6 MV flattening-filter free (FFF) beam in the RayStation treatment planning system ...<strong>Purpose:</strong> The purpose of this study is to provide technical information on commissioning the TrueBeam STx 6 MV flattening-filter free (FFF) beam in the RayStation treatment planning system (TPS) for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. <strong>Methods:</strong> For beam modeling, percent depth dose curves, profiles and output factors for jaw-collimated fields and stereotactic cones as well as X-jaws transmission were measured. For multi-leaf collimator (MLC) modeling, MLC model parameters such as offset, gain, curvature, leaf tip width, tongue and groove and transmission were determined and output factors for MLC-collimated fields were measured. Absolute dose calibration was also performed. For beam model and MLC model validation, the American Association of Physicists in Medicine Task Group-119 plans, clinical SRS and SBRT plans and end-to-end testing were performed. <strong>Results:</strong> Beam characteristics of the 6 MV FFF beam agreed well with those in the literature. Validation results showed that our beam model and MLC model were acceptable for SRS and SBRT treatments. <strong>Conclusions:</strong> The technical information and dosimetric data provided in this study will be a useful reference for other clinics/institutions which will commission the same machine energy in the RayStation TPS.展开更多
文摘Objective The aim of the study was to compare the efficacy and safety of whole brain radiotherapy(WBRT) used alone and combined with stereotactic radiosurgery(SRS) in the treatment of limited(1–4)brain metastases. Methods We searched for randomized controlled and matched-pair analysis trials comparing WBRT plus SRS versus WBRT alone for brain metastases. The primary outcomes were the overall survival(OS), intracranial control(IC), and localcontrol(LC). The secondary outcome was radiation toxicity. The log hazard ratios(lnHRs) and their variances were extracted from published Kaplan-Meier curves and pooled using the generic inverse variance method in the RevMan 5.3 software. The non-pooled outcome measures were evaluated using descriptive analysis. Results Three randomized controlled trials and two matched-pair analysis studies were included. There was no difference in the OS for limited brain metastases between the two groups [lnHR 0.91(95% CI 0.76–1.09, P = 0.32) vs. 0.72(95% CI 0.44–1.19, P = 0.20)]. The LC and IC were significantly higher in the combined treatment group [lnHR 0.69(95% CI 0.55–0.86, P = 0.001) vs. 0.41(95% CI 0.29–0.58, P < 0.0001)]. For patients with a single lesion, one trial showed a higher survival in the combined treatment group(median OS: 6.5 months vs. 4.9 months, P = 0.04). The combined treatment was not associated with significantly higher incidence of radiation toxicity. Conclusion Combined treatment with WBRT plus SRS should be recommended for patients with limited brain metastases based on the better LC and IC without increased toxicity. It should also be considered a routine treatment option for patients with solitary brain metastases based on the prolonged OS.
文摘<strong>Purpose:</strong> The purpose of this study is to provide technical information on commissioning the TrueBeam STx 6 MV flattening-filter free (FFF) beam in the RayStation treatment planning system (TPS) for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. <strong>Methods:</strong> For beam modeling, percent depth dose curves, profiles and output factors for jaw-collimated fields and stereotactic cones as well as X-jaws transmission were measured. For multi-leaf collimator (MLC) modeling, MLC model parameters such as offset, gain, curvature, leaf tip width, tongue and groove and transmission were determined and output factors for MLC-collimated fields were measured. Absolute dose calibration was also performed. For beam model and MLC model validation, the American Association of Physicists in Medicine Task Group-119 plans, clinical SRS and SBRT plans and end-to-end testing were performed. <strong>Results:</strong> Beam characteristics of the 6 MV FFF beam agreed well with those in the literature. Validation results showed that our beam model and MLC model were acceptable for SRS and SBRT treatments. <strong>Conclusions:</strong> The technical information and dosimetric data provided in this study will be a useful reference for other clinics/institutions which will commission the same machine energy in the RayStation TPS.