In the present work, we designed the new type of photonic crystals (PCs) as reflectors. Reflections from single layer of Al2O3/MgO PC help us in recapturing the light that does escape from the scintillation surface. P...In the present work, we designed the new type of photonic crystals (PCs) as reflectors. Reflections from single layer of Al2O3/MgO PC help us in recapturing the light that does escape from the scintillation surface. Photonic crystals in one dimension array of Al2O3 and MgO with silver at periodicities N = 1, 2 and 3 were used as a reflector around the surface of the scintillation volume. Scintillation detectors are widely used in nuclear medicine. The efficiency is an important parameter for characterizing the capability of the detectors. The counting efficiency of the detectors depends on the light emission induced by radiation. The light then was converted by the photomultiplier tube into electrical pulses. The efficiency may increase by an amount of 1.64% if MgO-Ag photonic crystals are used at periodicity N = 1 as a reflector.展开更多
The unfolding of neutron spectra from the pulse height distribution measured by a BC501A scintillation detector is accomplished by the application of artificial neural networks (ANN). A simple linear neural network wi...The unfolding of neutron spectra from the pulse height distribution measured by a BC501A scintillation detector is accomplished by the application of artificial neural networks (ANN). A simple linear neural network without biases and hidden layers is adopted. A set of monoenergetic detector response functions in the energy range from 0.25 MeV to 16 MeV with an energy interval of 0.25 MeV are generated by the Monte Carlo code O5S in the training phase of the unfolding process. The capability of ANN was demonstrated successfully using the Monte Carlo data itself and experimental data obtained from the Am-Be neutron source and D-T neutron source.展开更多
In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors b...In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg(50 t)range requiring more than 1 k W of cooling power. Most of the prior cooling methods become impractical at this level.For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen(LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the ‘‘Cooling Bus’ ’employed for the Panda X I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted.展开更多
Background In this study,three sample detectors have been prepared by using cerium-activated YAG nanoscintillator(Y_(3)Al_(5)O_(12):Ce^(3+))synthesized by sol-gel method and heat-treat at 900°C for 2 h in differe...Background In this study,three sample detectors have been prepared by using cerium-activated YAG nanoscintillator(Y_(3)Al_(5)O_(12):Ce^(3+))synthesized by sol-gel method and heat-treat at 900°C for 2 h in different atmospheres such as vacuum,air and nitrogen.Purpose Many studies about YAG:Ce^(3+)single crystal have been carried out,but the material at the nanoscale remains not enough understood.The objective of the present paper is to investigate the effects of annealing atmosphere on the scintillation properties and identify the suitable atmosphere that allow to design radiation detectors with high scintillation efficiency.Methods In order to accurately assess the scintillation properties,the nanoscintillator sample powders have been designed as a detector,in which,preparation operations such as surface homogenization and efficiency coupling with photomultiplier tube(PMT)window were developed.The study was performed usingγ-rays 662 keV released from137Cs radioactive source,the bi-alkali GDB-4FF PMT was used as a photodetector.Nuclear instrumentation chain was set up in order to collect the pulse height spectra,NaI:Tl single-crystal scintillator was used as a reference detector to estimate the scintillation light yield.The delayed coincidence method was used for measuring the scintillation decay time of nanoscintillator sample detectors.Results The sample detector annealed at vacuum atmosphere exhibits the best scintillation properties,the scintillation light yield was estimated to be 14,600±3400 ph/MeV and the fast component in the scintillation decay was 90 ns.Conclusion The vacuum is the suitable atmosphere which allows the development of radiation detectors with high scintillation efficiency.展开更多
Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors ...Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors the transient gamma-ray sky in the multi-mes-senger astronomy era.A compact CubeSat gamma-ray detector,including its hardware and firmware,was designed and implemented for the mission.The detector employs four Gd 2 Al 2 Ga 3 O 12:Ce(GAGG:Ce)scintillators coupled with four silicon photomultiplier(SiPM)arrays to achieve a high gamma-ray detection efficiency between 10 keV and 2 MeV with low power and small dimensions.The first detector designed by the undergraduate student team onboard a commercial CubeSat was launched into a Sun-synchronous orbit on October 29,2018.The detector was in a normal observation state and accumulated data for approximately one month after on-orbit functional and performance tests,which were conducted in 2019.展开更多
A short review is given for the determination of gross alpha activity ill urine;detailed information is collected including urine mineralization,separation of alpha emitters and source preparation.
文摘In the present work, we designed the new type of photonic crystals (PCs) as reflectors. Reflections from single layer of Al2O3/MgO PC help us in recapturing the light that does escape from the scintillation surface. Photonic crystals in one dimension array of Al2O3 and MgO with silver at periodicities N = 1, 2 and 3 were used as a reflector around the surface of the scintillation volume. Scintillation detectors are widely used in nuclear medicine. The efficiency is an important parameter for characterizing the capability of the detectors. The counting efficiency of the detectors depends on the light emission induced by radiation. The light then was converted by the photomultiplier tube into electrical pulses. The efficiency may increase by an amount of 1.64% if MgO-Ag photonic crystals are used at periodicity N = 1 as a reflector.
基金supported by the National Magnetic Confinement Fusion Science Program (Grant No. 2010GB111002)
文摘The unfolding of neutron spectra from the pulse height distribution measured by a BC501A scintillation detector is accomplished by the application of artificial neural networks (ANN). A simple linear neural network without biases and hidden layers is adopted. A set of monoenergetic detector response functions in the energy range from 0.25 MeV to 16 MeV with an energy interval of 0.25 MeV are generated by the Monte Carlo code O5S in the training phase of the unfolding process. The capability of ANN was demonstrated successfully using the Monte Carlo data itself and experimental data obtained from the Am-Be neutron source and D-T neutron source.
基金the Ministry of Science and Technology of China(No.2016YFA0400301)the grants for the XENON Dark Matter Project。
文摘In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg(50 t)range requiring more than 1 k W of cooling power. Most of the prior cooling methods become impractical at this level.For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen(LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the ‘‘Cooling Bus’ ’employed for the Panda X I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted.
文摘Background In this study,three sample detectors have been prepared by using cerium-activated YAG nanoscintillator(Y_(3)Al_(5)O_(12):Ce^(3+))synthesized by sol-gel method and heat-treat at 900°C for 2 h in different atmospheres such as vacuum,air and nitrogen.Purpose Many studies about YAG:Ce^(3+)single crystal have been carried out,but the material at the nanoscale remains not enough understood.The objective of the present paper is to investigate the effects of annealing atmosphere on the scintillation properties and identify the suitable atmosphere that allow to design radiation detectors with high scintillation efficiency.Methods In order to accurately assess the scintillation properties,the nanoscintillator sample powders have been designed as a detector,in which,preparation operations such as surface homogenization and efficiency coupling with photomultiplier tube(PMT)window were developed.The study was performed usingγ-rays 662 keV released from137Cs radioactive source,the bi-alkali GDB-4FF PMT was used as a photodetector.Nuclear instrumentation chain was set up in order to collect the pulse height spectra,NaI:Tl single-crystal scintillator was used as a reference detector to estimate the scintillation light yield.The delayed coincidence method was used for measuring the scintillation decay time of nanoscintillator sample detectors.Results The sample detector annealed at vacuum atmosphere exhibits the best scintillation properties,the scintillation light yield was estimated to be 14,600±3400 ph/MeV and the fast component in the scintillation decay was 90 ns.Conclusion The vacuum is the suitable atmosphere which allows the development of radiation detectors with high scintillation efficiency.
基金supported by the Tsinghua University Initiative Scientific Research Program,the National Natural Science Foundation of China(Nos.11633003,12025301,and 11821303)the National Key R&D Program of China(Nos.2018YFA0404502 and 2016YFA040080X).
文摘Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors the transient gamma-ray sky in the multi-mes-senger astronomy era.A compact CubeSat gamma-ray detector,including its hardware and firmware,was designed and implemented for the mission.The detector employs four Gd 2 Al 2 Ga 3 O 12:Ce(GAGG:Ce)scintillators coupled with four silicon photomultiplier(SiPM)arrays to achieve a high gamma-ray detection efficiency between 10 keV and 2 MeV with low power and small dimensions.The first detector designed by the undergraduate student team onboard a commercial CubeSat was launched into a Sun-synchronous orbit on October 29,2018.The detector was in a normal observation state and accumulated data for approximately one month after on-orbit functional and performance tests,which were conducted in 2019.
文摘A short review is given for the determination of gross alpha activity ill urine;detailed information is collected including urine mineralization,separation of alpha emitters and source preparation.