Different configurations for the monochroma-tor crystals and the analyzer crystals have been used in hard X-ray diffraction enhanced imaging (DEI) methods to over-come the complex task to adjust each of them to the id...Different configurations for the monochroma-tor crystals and the analyzer crystals have been used in hard X-ray diffraction enhanced imaging (DEI) methods to over-come the complex task to adjust each of them to the ideal position. Here we present a very compact DEI configuration, and preliminary results of experiments performed at the Beijing Synchrotron Radiation Facility (BSRF) using only two crystals: the first one acting as monochromator and the second one as analyzer in the Bragg geometry. Refraction contrast images characterized by high contrast and spatial resolution are obtained and compared with absorption im-ages. Differences among these images will be outlined and discussed emphasizing the potential capabilities of this very simple layout that guarantees a high transmission efficiency.展开更多
In SSRF, the design of 1st crystal cooling geometry of double crystal monochromator with sagittal focus is mainly reported by China. Our simulation indicates that the broadening of the full width at half maximum of th...In SSRF, the design of 1st crystal cooling geometry of double crystal monochromator with sagittal focus is mainly reported by China. Our simulation indicates that the broadening of the full width at half maximum of the rocking curve of the double crystal monochromator induced by the heat load is about 3.7 μrad, and is in agreement with the experimental value of 5 μrad. Our scheme showed that the photon flux is reliably linear with electron current of the storage ring, which is extracted from the monochromator.展开更多
文摘Different configurations for the monochroma-tor crystals and the analyzer crystals have been used in hard X-ray diffraction enhanced imaging (DEI) methods to over-come the complex task to adjust each of them to the ideal position. Here we present a very compact DEI configuration, and preliminary results of experiments performed at the Beijing Synchrotron Radiation Facility (BSRF) using only two crystals: the first one acting as monochromator and the second one as analyzer in the Bragg geometry. Refraction contrast images characterized by high contrast and spatial resolution are obtained and compared with absorption im-ages. Differences among these images will be outlined and discussed emphasizing the potential capabilities of this very simple layout that guarantees a high transmission efficiency.
基金Supported by cooling research of double crystal monochromator used by synchrotron radiation(10205024)
文摘In SSRF, the design of 1st crystal cooling geometry of double crystal monochromator with sagittal focus is mainly reported by China. Our simulation indicates that the broadening of the full width at half maximum of the rocking curve of the double crystal monochromator induced by the heat load is about 3.7 μrad, and is in agreement with the experimental value of 5 μrad. Our scheme showed that the photon flux is reliably linear with electron current of the storage ring, which is extracted from the monochromator.