A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achie...A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.展开更多
Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the...Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.展开更多
A new and simple type of electron gun is presented.Unlike conventional electron guns,which require a heated filament or extractor,accelerator and focusing electrodes,this gun uses the collimated electron microchannels...A new and simple type of electron gun is presented.Unlike conventional electron guns,which require a heated filament or extractor,accelerator and focusing electrodes,this gun uses the collimated electron microchannels of an inertial electrostatic confinement(IEC) discharge to achieve the same outcome.A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge.Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode.This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid.The internal operating pressure range of the gun is 35-190 m Torr.A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential.The chamber was operated at pressures of 4-12 m Torr.The measured current produced by the gun was 0.1-3 m A(0.2-14 m A corrected measurement) for discharge currents of 1-45 m A and discharge voltages of 0.5-12 k V.The collimated electron beam emerges from the aperture into the vacuum chamber.The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun.This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.展开更多
The density, drift velocity and reproducibility of the plasma produced by a cable plasma gun array have been measured with a charge collector array. The plasma is used to prefill a coaxial plasma-opening switch with a...The density, drift velocity and reproducibility of the plasma produced by a cable plasma gun array have been measured with a charge collector array. The plasma is used to prefill a coaxial plasma-opening switch with a conducting time approaching 0.4 μs. The reproducibility of the plasma source in subsequent shots is better than 5%. Near the gun nozzle and the opposite electrode, the plasma density amounts to 1015cm-3, which is 2 times to 3 times that in the gap between the two coaxial electrodes. A plasma drift velocity of about 2.4 cm/μs is observed from the time of flight of the charged particles. Both plasma density and drift velocity increase almost linearly with the rise in charge voltage.展开更多
In this study, SiOx films were deposited by a dielectric barrier discharge (DBD) plasma gun at an atmospheric pressure. The relationship of the film structures with plasma powers was investigated by Fourier transfor...In this study, SiOx films were deposited by a dielectric barrier discharge (DBD) plasma gun at an atmospheric pressure. The relationship of the film structures with plasma powers was investigated by Fourier transform infrared spectroscopy (FTIR), and scanning electron microscope (SEM). It was shown that an uniform and cross-linking structure film was formed by the DBD gun. As an application, the SiOx films were deposited on a carbon steel surface for the anti-corrosion purpose. The experiment was carried out in a 0.1 M NaCl solution. It was found that a very good anti-corrosive property was obtained, i.e., the corrosion rate was decreased c.a. 15 times in 5% NaCl solution compared to the non-SiOx coated steel, as detected by the potentiodynamic polarization measurement.展开更多
文摘A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.
文摘Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.
文摘A new and simple type of electron gun is presented.Unlike conventional electron guns,which require a heated filament or extractor,accelerator and focusing electrodes,this gun uses the collimated electron microchannels of an inertial electrostatic confinement(IEC) discharge to achieve the same outcome.A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge.Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode.This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid.The internal operating pressure range of the gun is 35-190 m Torr.A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential.The chamber was operated at pressures of 4-12 m Torr.The measured current produced by the gun was 0.1-3 m A(0.2-14 m A corrected measurement) for discharge currents of 1-45 m A and discharge voltages of 0.5-12 k V.The collimated electron beam emerges from the aperture into the vacuum chamber.The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun.This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.
基金The project supported by the National Natural Science Foundation of the China(No.10035O20)
文摘The density, drift velocity and reproducibility of the plasma produced by a cable plasma gun array have been measured with a charge collector array. The plasma is used to prefill a coaxial plasma-opening switch with a conducting time approaching 0.4 μs. The reproducibility of the plasma source in subsequent shots is better than 5%. Near the gun nozzle and the opposite electrode, the plasma density amounts to 1015cm-3, which is 2 times to 3 times that in the gap between the two coaxial electrodes. A plasma drift velocity of about 2.4 cm/μs is observed from the time of flight of the charged particles. Both plasma density and drift velocity increase almost linearly with the rise in charge voltage.
基金supported by the National Natural Science Foundation of China(No.10475010)
文摘In this study, SiOx films were deposited by a dielectric barrier discharge (DBD) plasma gun at an atmospheric pressure. The relationship of the film structures with plasma powers was investigated by Fourier transform infrared spectroscopy (FTIR), and scanning electron microscope (SEM). It was shown that an uniform and cross-linking structure film was formed by the DBD gun. As an application, the SiOx films were deposited on a carbon steel surface for the anti-corrosion purpose. The experiment was carried out in a 0.1 M NaCl solution. It was found that a very good anti-corrosive property was obtained, i.e., the corrosion rate was decreased c.a. 15 times in 5% NaCl solution compared to the non-SiOx coated steel, as detected by the potentiodynamic polarization measurement.