This paper reports on the use of a kite-based system for measuring low-altitude particulate matter (PM) concentrations over grassland in Inner Mongolia. The motivation came from PM-concentration measurements at height...This paper reports on the use of a kite-based system for measuring low-altitude particulate matter (PM) concentrations over grassland in Inner Mongolia. The motivation came from PM-concentration measurements at heights below 3 m over non-erodible surfaces which showed constant concentrations and made flux calculations relatively uncertain. One aim was the quantification of wind-driven matter fluxes across ecosystem boundaries, where the relevant layer can be assumed at heights below 100 m. Compared to other measurement techniques (e.g. LIDAR, towers and airborne systems) kite-based systems represent an inexpensive, highly flexible research tool which is well-suited for application in remote sites. The basis of the introduced system is a 4 m2 Parafoil kite which has enough lifting capacity to carry equipment of about 6 kg at wind velocities between 3 ms-1 to nearly 20 ms-1. A self-adjusting platform was constructed to balance moves and to carry a portable Environmental Dust Monitor (EDM), anemometer and a GPS receiver. So, all parameters necessary for a vertical profile of dust fluxes could be measured. In the first flights the applied kite-based dust profiling system (KIDS) was examined according to general technical application problems. Firstly, the influence of diverse surface characteristics, the flying condition and height-stability was tested. The result suggests that surface characteristics in general have a higher influence than the optimal wind velocity, which ranged from 9 ms-1 to 17 ms-1. Secondly, uncertainties in the measured data were quantified and assessed. The uncertainties in wind velocity measurements due to motion in horizontal and vertical direction were not higher than 0.45% - 0.65% and 1.8% - 2.2% during the kite ascent. The outcome of the study illustrates the suitable application of KIDS for low-altitude measurements in remote sites.展开更多
文摘This paper reports on the use of a kite-based system for measuring low-altitude particulate matter (PM) concentrations over grassland in Inner Mongolia. The motivation came from PM-concentration measurements at heights below 3 m over non-erodible surfaces which showed constant concentrations and made flux calculations relatively uncertain. One aim was the quantification of wind-driven matter fluxes across ecosystem boundaries, where the relevant layer can be assumed at heights below 100 m. Compared to other measurement techniques (e.g. LIDAR, towers and airborne systems) kite-based systems represent an inexpensive, highly flexible research tool which is well-suited for application in remote sites. The basis of the introduced system is a 4 m2 Parafoil kite which has enough lifting capacity to carry equipment of about 6 kg at wind velocities between 3 ms-1 to nearly 20 ms-1. A self-adjusting platform was constructed to balance moves and to carry a portable Environmental Dust Monitor (EDM), anemometer and a GPS receiver. So, all parameters necessary for a vertical profile of dust fluxes could be measured. In the first flights the applied kite-based dust profiling system (KIDS) was examined according to general technical application problems. Firstly, the influence of diverse surface characteristics, the flying condition and height-stability was tested. The result suggests that surface characteristics in general have a higher influence than the optimal wind velocity, which ranged from 9 ms-1 to 17 ms-1. Secondly, uncertainties in the measured data were quantified and assessed. The uncertainties in wind velocity measurements due to motion in horizontal and vertical direction were not higher than 0.45% - 0.65% and 1.8% - 2.2% during the kite ascent. The outcome of the study illustrates the suitable application of KIDS for low-altitude measurements in remote sites.
文摘为提高电除尘器对循环流化床(CFB)锅炉宽负荷工况的适应性,在某135 MW机组CFB锅炉上对不同工况下电除尘器运行功率及其出口烟尘颗粒排放控制进行了试验研究,得到电除尘器运行功率与其出口颗粒物排放质量浓度的关系。结果表明:由于负荷的变化导致烟气温度改变,而烟气温度直接影响电除尘器运行功率,故CFB锅炉电除尘器除尘效果对机组负荷的变化极为敏感;烟气温度在100~200℃内,135 MW机组CFB锅炉烟气温度每降低20℃,烟尘比电阻可降低约1个数量级,电除尘器运行功率可提高约100 k W;降低烟气温度是宽负荷CFB锅炉电除尘器保持稳定高效运行的一项重要措施。