HIV-1 p24 detection provides a means to aid the early diagnosis of HIV-1 infection, track the progression of disease and assess the efficacy of antiretroviral therapy. In the present study, three monoclonal antibodies...HIV-1 p24 detection provides a means to aid the early diagnosis of HIV-1 infection, track the progression of disease and assess the efficacy of antiretroviral therapy. In the present study, three monoclonal antibodies (mAbs) p3JB9, p5F1 and p6F4 against HIV-1 p24 were generated. All mAbs could detect p24 of HIV-1ⅢB, HIV-1Ada-M, HIV-174v mAbs p5F1 and p6F4 could detect HIV-1KM018, while p3JB9 could not. Three mAbs did not react with HIV-2ROD, HIV-2CBL-20 and SIVagmTYO-1. The recognized epitope of p5F1 was located on the Gag amino acid region DCKTILKALGPAATLEEMMTAC. The p5F1 was used to establish a modified sandwich ELISA with rabbit anti-p24 serum and showed good specificity and high sensitivity, which has been used to measure HIV-1 p24 antigen levels in research. Cellular & Molecular Immunology.展开更多
To experimentally evaluate the ectopic osteogenetic capacity of synthesized BMP2-derived peptide P24 combined with poly lactic-co-glycolic acid (PLGA), Wistar rats were divided into two groups: group A, in which BM...To experimentally evaluate the ectopic osteogenetic capacity of synthesized BMP2-derived peptide P24 combined with poly lactic-co-glycolic acid (PLGA), Wistar rats were divided into two groups: group A, in which BMP2-derived peptide P24/PLGA complex was implanted, and group B which received simple PLGA implant. The complex was respectively implanted into the back muscles of rats. Samples were taken the 1st, 4th, 8th, and the 12th week after the implantation. Their bone formation was detected by X-ray examination, and tissue response was histologically observed. Western blotting was used for the detection of the expression of collagen Ⅰ (Col- Ⅰ ) and osteopontin (OPN). There was acute inflammation in the tissue around both types of implants at early stage. The cartilage was found around implant areas 4 weeks after the implantation of BMP2-derived peptide p24/PLGA complex, 8 weeks after the implantation, osteoblasts were found, and 12 weeks after the implantation, typical trabecular bone structure was observed. In group B, after 12 weeks, no osteoblasts were found. It is concluded that PLGA is an ideal scaffold material for bone tissue engineering. BMP2-derived peptide can start endochondral ossification and is more effective in inducing ectopic osteogenesis.展开更多
Objective To develop a rapid,highly sensitive quantitative method for detecting P24 antigen based on near-infrared fluorescent microsphere immunochromatography.Methods First,we prepared a lateral flow assay test strip...Objective To develop a rapid,highly sensitive quantitative method for detecting P24 antigen based on near-infrared fluorescent microsphere immunochromatography.Methods First,we prepared a lateral flow assay test strip,and labeled the detection antibody using a fluorescent microsphere.Second,we optimized the antibody labeling conditions.Third,we optimized the detection conditions.Fourth,we created a working curve.Fifth,we conducted a methodological assessment of the established fluorescent microsphere immunochromatography method.Sixty-six clinical samples were tested,and we compared the established fluorescent microsphere immunochromatography with the quantitative ELISA method.Results According to the working curve,the detection limit of the method is 3.4 pg/mL,and the detection range is 3.4 pg/mL to 10 ng/mL.The average intra-assay recovery was 99.6%,and the Coefficient of Variation(CV)was 5.4%–8.6%;the average inter-assay recovery was 97.3%,and the CV was 8.5%–11%.The detection rate of fluorescent microsphere immunochromatography was higher than ELISA method,and had a good correlation with ELISA.Conclusion The P24 antigen quantitative detection method based on near-infrared fluorescent microsphere immunochromatography has the advantages of rapid detection,high sensitivity,and wide detection range;thus,it is suitable for early clinical diagnosis and continuous monitoring of AIDS.展开更多
基金grants from the National Natural Science Foundation of China (39500137, 30471605, 30671960) the Natural Science Foundation of Yunnan (95C0099Q)+3 种基金 Key Technological R&D Program of China (2004BA719A14) and Yunnan (2004NG12) CAS Projects (KSZ85-0108, STZ-01-17 KSCX2-SW-216 KSCX 1-SW- 11, KSCX 1-YW-R- 15).
文摘HIV-1 p24 detection provides a means to aid the early diagnosis of HIV-1 infection, track the progression of disease and assess the efficacy of antiretroviral therapy. In the present study, three monoclonal antibodies (mAbs) p3JB9, p5F1 and p6F4 against HIV-1 p24 were generated. All mAbs could detect p24 of HIV-1ⅢB, HIV-1Ada-M, HIV-174v mAbs p5F1 and p6F4 could detect HIV-1KM018, while p3JB9 could not. Three mAbs did not react with HIV-2ROD, HIV-2CBL-20 and SIVagmTYO-1. The recognized epitope of p5F1 was located on the Gag amino acid region DCKTILKALGPAATLEEMMTAC. The p5F1 was used to establish a modified sandwich ELISA with rabbit anti-p24 serum and showed good specificity and high sensitivity, which has been used to measure HIV-1 p24 antigen levels in research. Cellular & Molecular Immunology.
基金This project was supported by grants from the National Natural Sciences Foundation of China (Nos. 30470483,30200063, 30170270)a grant from Chengguang Program for Young Scientists of Wuhan Municipal Government (No. 2004500607110)
文摘To experimentally evaluate the ectopic osteogenetic capacity of synthesized BMP2-derived peptide P24 combined with poly lactic-co-glycolic acid (PLGA), Wistar rats were divided into two groups: group A, in which BMP2-derived peptide P24/PLGA complex was implanted, and group B which received simple PLGA implant. The complex was respectively implanted into the back muscles of rats. Samples were taken the 1st, 4th, 8th, and the 12th week after the implantation. Their bone formation was detected by X-ray examination, and tissue response was histologically observed. Western blotting was used for the detection of the expression of collagen Ⅰ (Col- Ⅰ ) and osteopontin (OPN). There was acute inflammation in the tissue around both types of implants at early stage. The cartilage was found around implant areas 4 weeks after the implantation of BMP2-derived peptide p24/PLGA complex, 8 weeks after the implantation, osteoblasts were found, and 12 weeks after the implantation, typical trabecular bone structure was observed. In group B, after 12 weeks, no osteoblasts were found. It is concluded that PLGA is an ideal scaffold material for bone tissue engineering. BMP2-derived peptide can start endochondral ossification and is more effective in inducing ectopic osteogenesis.
基金supported by the National Natural Science Foundation of China[no.21677006]National Key Research and Development Project[2017YFC1200500].
文摘Objective To develop a rapid,highly sensitive quantitative method for detecting P24 antigen based on near-infrared fluorescent microsphere immunochromatography.Methods First,we prepared a lateral flow assay test strip,and labeled the detection antibody using a fluorescent microsphere.Second,we optimized the antibody labeling conditions.Third,we optimized the detection conditions.Fourth,we created a working curve.Fifth,we conducted a methodological assessment of the established fluorescent microsphere immunochromatography method.Sixty-six clinical samples were tested,and we compared the established fluorescent microsphere immunochromatography with the quantitative ELISA method.Results According to the working curve,the detection limit of the method is 3.4 pg/mL,and the detection range is 3.4 pg/mL to 10 ng/mL.The average intra-assay recovery was 99.6%,and the Coefficient of Variation(CV)was 5.4%–8.6%;the average inter-assay recovery was 97.3%,and the CV was 8.5%–11%.The detection rate of fluorescent microsphere immunochromatography was higher than ELISA method,and had a good correlation with ELISA.Conclusion The P24 antigen quantitative detection method based on near-infrared fluorescent microsphere immunochromatography has the advantages of rapid detection,high sensitivity,and wide detection range;thus,it is suitable for early clinical diagnosis and continuous monitoring of AIDS.