Blastomycosis and histoplasmosis manifest as lung and systemic fungal infections in mammals caused by Histoplasma capsulatum, and Blastomyces dermatitidis. These infections exhibit cross reactivity of antibodies which...Blastomycosis and histoplasmosis manifest as lung and systemic fungal infections in mammals caused by Histoplasma capsulatum, and Blastomyces dermatitidis. These infections exhibit cross reactivity of antibodies which makes a correct diagnosis potentially elusive. The purpose of this study was to gain an understanding of which isoelectric focusing fractions (RotoforTM) of B. dermatitidis were reactive or cross reactive with serum specimens from dogs infected with B. dermatitidis, H. capsulatum, and Cryptococcus neoformans. Three serum specimens from dogs that were infected with B. dermatitidis, two dogs infected with H. capsulatum, and one dog infected with C. neoformans were assayed against the 20 B. dermatitidis RotoforTM fractions. Reactivity was determined using the indirect enzyme linked immunoassay (ELISA). Reactivity with B. dermatitidis was found predominantly in the protein fractions 1 - 6, and cross reactivity with H. capsulatum, and C. neoformans sera was found within the B. dermatitidis protein fractions 15 - 19.展开更多
Blastomyces dermatitidis, the causative agent of blastomycosis, a potentially lethal dimorphic fungal disease of humans and animals has been difficult to diagnose in the clinical laboratory. We are attempting to devel...Blastomyces dermatitidis, the causative agent of blastomycosis, a potentially lethal dimorphic fungal disease of humans and animals has been difficult to diagnose in the clinical laboratory. We are attempting to develop and improve immunodiagnostic assays by producing novel yeast lysate reagents for the detection of antibodies in blastomycosis. The objective of this study was to use lysate antigens prepared from four B. dermatitidis antigens isolated from dogs infected with blastomycosis from two different endemic areas (Wisconsin and Tennessee) testing for the detection of antibodies in serum specimens from immunized rabbits and infected dogs using the indirect ELISA. In the dog sera, absorbance values ranged from 0.774 to 1.350, while the rabbit sera values ranged from 0.533 to 1.191. Antigen T-58 appeared to lack any geographical specificity in antibody detection, which could prove useful in future immunodiagnostic detection of blastomycosis infections.展开更多
Blastomycosis, a systemic fungal disease, caused by the dimorphic fungus Blastomyces dermatitidis, has continually presented clinicians with concerns with regard to laboratory diagnosis and prevention. For years resea...Blastomycosis, a systemic fungal disease, caused by the dimorphic fungus Blastomyces dermatitidis, has continually presented clinicians with concerns with regard to laboratory diagnosis and prevention. For years researchers have strived to develop antigens with a high degree of sensitivity and specificity. The purpose of this study was to gain a bet- ter understanding of how two novel yeast lysate antigens, prepared from two B. dermatitidis isolates by different meth- ods, would be able to detect antibody responses in immunized rabbits in a specific and sensitive manner. The en- zyme-linked immunosorbent assay (ELISA) was used to evaluate antibody in serum specimens with yeast lysate re- agents prepared after allowing yeast cells to lyse for 1 or 7 days. The results indicated that reactivity was greater with the day 7 antigens, with both the B5896 and 597 B. dermatitidis isolates, when compared to the day 1 antigens;in con- trast the day 1 preparations exhibited less cross reactivity when assayed against anti-Histoplasma capsulatum serum specimens.展开更多
This present study was designed to evaluate four different Blastomyces dermatitidis antibody-antigen combinations (B5896 and T-58 antibodies and B5896 and WI-R antigens) for the detection of antigen in 36 urine specim...This present study was designed to evaluate four different Blastomyces dermatitidis antibody-antigen combinations (B5896 and T-58 antibodies and B5896 and WI-R antigens) for the detection of antigen in 36 urine specimens from dogs with blastomycosis using a standard indirect ELISA (STD) and a biotin-streptavidin ELISA (B-SA). The antigen detection sensitivity values ranged from 81% (B-SA: T-58 Ab + WI-R Ag) to 100% (STD and B-SA: B5896 Ab + WI-R Ag;B5896 Ab + B5896 Ag) with the antibody-antigen combinations in the two assays. Optimal detection was evidenced when the B5896 Ab was allowed to react with the urine specimens for 30 min at 37?C and then placed in the B-SA ELISA plates containing the B5896 Ag. The greatest absorbance value obtained with this antibody-antigen com-bination was 0.903 (range of 0.596 - 0.903) as compared to the control value of 1.246. The difference between the control absorbance and the test absorbance values was 0.343 which was considerably greater than the control-test values with the other combinations. This study thus showed that the results obtained in antigen detection assays are dependent upon the antibody used to react with the urine specimens as well as the antigen used in the enzyme immunoassay.展开更多
The objective of our study was to compare two B. dermatitidis yeast phase lysate antigens [ERC-2, dog Wisconsin;85, soil Georgia, ATCC 56,920] for detecting antibody in 38 serum specimens [pre-treatment, 30-day, and 6...The objective of our study was to compare two B. dermatitidis yeast phase lysate antigens [ERC-2, dog Wisconsin;85, soil Georgia, ATCC 56,920] for detecting antibody in 38 serum specimens [pre-treatment, 30-day, and 60-day post treatment] from dogs with diagnosed blastomycosis. The mean absorbance values obtained with the two antigens (N = 38) were ERC-2 = 2.359 and 85 = 2.189. The mean absorbance values when the sera were divided into the three treatment groups were as follows pre-treatment: Isolate ERC-2 had an absorbance value of 2.418;Isolate 85 had an absorbance value of 2.688, 30-day post treatment: ERC-2 had an absorbance value of 2.452;85 had an absorbance value of 2.303 and 60-day post treatment: ERC-2 had an absorbance value of 2.150;85 had an absorbance value of 2.073 with the mean absorbance values of all treatment groups were ERC-2: 2.229 and 85: 2.141. This study indicates the potential for further evaluations of the two lysate antigens with regard to antibody detection in dog sera with the ERC-2 reagent slightly more reactive than the 85 lysate antigen.展开更多
文摘Blastomycosis and histoplasmosis manifest as lung and systemic fungal infections in mammals caused by Histoplasma capsulatum, and Blastomyces dermatitidis. These infections exhibit cross reactivity of antibodies which makes a correct diagnosis potentially elusive. The purpose of this study was to gain an understanding of which isoelectric focusing fractions (RotoforTM) of B. dermatitidis were reactive or cross reactive with serum specimens from dogs infected with B. dermatitidis, H. capsulatum, and Cryptococcus neoformans. Three serum specimens from dogs that were infected with B. dermatitidis, two dogs infected with H. capsulatum, and one dog infected with C. neoformans were assayed against the 20 B. dermatitidis RotoforTM fractions. Reactivity was determined using the indirect enzyme linked immunoassay (ELISA). Reactivity with B. dermatitidis was found predominantly in the protein fractions 1 - 6, and cross reactivity with H. capsulatum, and C. neoformans sera was found within the B. dermatitidis protein fractions 15 - 19.
文摘Blastomyces dermatitidis, the causative agent of blastomycosis, a potentially lethal dimorphic fungal disease of humans and animals has been difficult to diagnose in the clinical laboratory. We are attempting to develop and improve immunodiagnostic assays by producing novel yeast lysate reagents for the detection of antibodies in blastomycosis. The objective of this study was to use lysate antigens prepared from four B. dermatitidis antigens isolated from dogs infected with blastomycosis from two different endemic areas (Wisconsin and Tennessee) testing for the detection of antibodies in serum specimens from immunized rabbits and infected dogs using the indirect ELISA. In the dog sera, absorbance values ranged from 0.774 to 1.350, while the rabbit sera values ranged from 0.533 to 1.191. Antigen T-58 appeared to lack any geographical specificity in antibody detection, which could prove useful in future immunodiagnostic detection of blastomycosis infections.
文摘Blastomycosis, a systemic fungal disease, caused by the dimorphic fungus Blastomyces dermatitidis, has continually presented clinicians with concerns with regard to laboratory diagnosis and prevention. For years researchers have strived to develop antigens with a high degree of sensitivity and specificity. The purpose of this study was to gain a bet- ter understanding of how two novel yeast lysate antigens, prepared from two B. dermatitidis isolates by different meth- ods, would be able to detect antibody responses in immunized rabbits in a specific and sensitive manner. The en- zyme-linked immunosorbent assay (ELISA) was used to evaluate antibody in serum specimens with yeast lysate re- agents prepared after allowing yeast cells to lyse for 1 or 7 days. The results indicated that reactivity was greater with the day 7 antigens, with both the B5896 and 597 B. dermatitidis isolates, when compared to the day 1 antigens;in con- trast the day 1 preparations exhibited less cross reactivity when assayed against anti-Histoplasma capsulatum serum specimens.
文摘This present study was designed to evaluate four different Blastomyces dermatitidis antibody-antigen combinations (B5896 and T-58 antibodies and B5896 and WI-R antigens) for the detection of antigen in 36 urine specimens from dogs with blastomycosis using a standard indirect ELISA (STD) and a biotin-streptavidin ELISA (B-SA). The antigen detection sensitivity values ranged from 81% (B-SA: T-58 Ab + WI-R Ag) to 100% (STD and B-SA: B5896 Ab + WI-R Ag;B5896 Ab + B5896 Ag) with the antibody-antigen combinations in the two assays. Optimal detection was evidenced when the B5896 Ab was allowed to react with the urine specimens for 30 min at 37?C and then placed in the B-SA ELISA plates containing the B5896 Ag. The greatest absorbance value obtained with this antibody-antigen com-bination was 0.903 (range of 0.596 - 0.903) as compared to the control value of 1.246. The difference between the control absorbance and the test absorbance values was 0.343 which was considerably greater than the control-test values with the other combinations. This study thus showed that the results obtained in antigen detection assays are dependent upon the antibody used to react with the urine specimens as well as the antigen used in the enzyme immunoassay.
文摘The objective of our study was to compare two B. dermatitidis yeast phase lysate antigens [ERC-2, dog Wisconsin;85, soil Georgia, ATCC 56,920] for detecting antibody in 38 serum specimens [pre-treatment, 30-day, and 60-day post treatment] from dogs with diagnosed blastomycosis. The mean absorbance values obtained with the two antigens (N = 38) were ERC-2 = 2.359 and 85 = 2.189. The mean absorbance values when the sera were divided into the three treatment groups were as follows pre-treatment: Isolate ERC-2 had an absorbance value of 2.418;Isolate 85 had an absorbance value of 2.688, 30-day post treatment: ERC-2 had an absorbance value of 2.452;85 had an absorbance value of 2.303 and 60-day post treatment: ERC-2 had an absorbance value of 2.150;85 had an absorbance value of 2.073 with the mean absorbance values of all treatment groups were ERC-2: 2.229 and 85: 2.141. This study indicates the potential for further evaluations of the two lysate antigens with regard to antibody detection in dog sera with the ERC-2 reagent slightly more reactive than the 85 lysate antigen.