The sensitivity of Doppler wind lidar is an important parameter which affects the performance of Doppler wind lidar. Aerosol scattering ratio, atmospheric temperature, and wind speed obviously affect the measurement o...The sensitivity of Doppler wind lidar is an important parameter which affects the performance of Doppler wind lidar. Aerosol scattering ratio, atmospheric temperature, and wind speed obviously affect the measurement of Doppler wind lidar with iodine filter. We discuss about the relationship between the measurement sensitivity and the above atmospheric parameters. The numerical relationship between them is given through the theoretical simulation and calculation.展开更多
This note reports a new type of incoherent pulse laser Doppler lidar velocimeter with iodine molecular filter as a frequency discriminator. Its transmitter subsystem applies a Nd:YAG pulse laser which is injected with...This note reports a new type of incoherent pulse laser Doppler lidar velocimeter with iodine molecular filter as a frequency discriminator. Its transmitter subsystem applies a Nd:YAG pulse laser which is injected with a single longitudinal-mode diode pumped continuous seeder laser. The field experiment proved that this velocimeter measurement results are consistent with those measured by photoelectric velocimeter. Measurements of eight different velocities show that the standard deviation is 0.56m/s, the range resolution is 3.75m.展开更多
Doppler global velocimetry (DGV) has already been shown to be an interesting technique capable of measuring the three components of velocity in a plane. A 1-component DGV system is currently under development at the...Doppler global velocimetry (DGV) has already been shown to be an interesting technique capable of measuring the three components of velocity in a plane. A 1-component DGV system is currently under development at the LMFA, using a stabilized continuous wave (CW) argon ion laser for ermssion, lne receiver Ieatures only one camera for both signal and reference images and incorporates a DEF1 system to adjust the incident laser light frequency and its transmission coefficient on the iodine cell absorption line. A description of the whole system is presented and a validation with measurements of axial velocities at several positions in a round free jet is proposed.展开更多
基金the National Natural Science Foundation of China under Grant No.40427001,60578038,and 40505003
文摘The sensitivity of Doppler wind lidar is an important parameter which affects the performance of Doppler wind lidar. Aerosol scattering ratio, atmospheric temperature, and wind speed obviously affect the measurement of Doppler wind lidar with iodine filter. We discuss about the relationship between the measurement sensitivity and the above atmospheric parameters. The numerical relationship between them is given through the theoretical simulation and calculation.
基金This work was supported by the National "863" Project (Grant No. 863-308-14-03(5))the National Natural Science Foundation of China (Grant No. 60178017).
文摘This note reports a new type of incoherent pulse laser Doppler lidar velocimeter with iodine molecular filter as a frequency discriminator. Its transmitter subsystem applies a Nd:YAG pulse laser which is injected with a single longitudinal-mode diode pumped continuous seeder laser. The field experiment proved that this velocimeter measurement results are consistent with those measured by photoelectric velocimeter. Measurements of eight different velocities show that the standard deviation is 0.56m/s, the range resolution is 3.75m.
基金the CIRT (Consortium Indus trie Recherche en Turbomachines) which is supporting this workmore particularly at the LMFA, Alain Ef fernelli for building many elements of the receiver, Gil bert Halter for helping in the collimation processAndre Vouillarmet for his advice in this project.
文摘Doppler global velocimetry (DGV) has already been shown to be an interesting technique capable of measuring the three components of velocity in a plane. A 1-component DGV system is currently under development at the LMFA, using a stabilized continuous wave (CW) argon ion laser for ermssion, lne receiver Ieatures only one camera for both signal and reference images and incorporates a DEF1 system to adjust the incident laser light frequency and its transmission coefficient on the iodine cell absorption line. A description of the whole system is presented and a validation with measurements of axial velocities at several positions in a round free jet is proposed.