Ag/AgCl electrode has been prepared using pressed powder techniques. In order to verify the feasibility of this type of electrode used as detecting electric field generated by vessels in seawater, its characteristics ...Ag/AgCl electrode has been prepared using pressed powder techniques. In order to verify the feasibility of this type of electrode used as detecting electric field generated by vessels in seawater, its characteristics of DC resistance, low frequency AC impedance, and receiving impedance in artificial seawater have been studied by polarization measurements, low frequency electrochemical impedance spectra, the open and short circuit cell conditions. The results show that the electrode can keep a low resistance when it responses the weak electrostatic field in seawater. The AC impedance of the electrode decreases as the frequency of the signal increasing. The receiving impedance decreases when the frequency of external field increases too. The valid detection bandwidth is determined by the properties of the impedance and the reactions occurring on the surface of the electrode.展开更多
Detection of high impedance faults(HIFs)has been traditionally a main challenge in the protection of distribution systems,since they do not generate enough current to be reliably detected by conventional over-current ...Detection of high impedance faults(HIFs)has been traditionally a main challenge in the protection of distribution systems,since they do not generate enough current to be reliably detected by conventional over-current relays.Data-based methods are alternative HIF detection methods which avoid threshold settings by training a classification or regression model.However,most of them lack interpretability and are not compatible with various distribution networks.This paper proposes an object detection-based HIF detection method,which has higher visualization and can be easily applied to different scenarios.First,based on the analysis of HIFs,a Butterworth band-pass filter is designed for HIF harmonic feature extraction.Subsequently,based on the synchronized data provided by distribution-level phasor measurement units,global HIF feature gray-scale images are formed through combining the topology information of the distribution network.To further enhance the feature information,a locally excitatory globally inhibitory oscillator region attention mechanism(LEGIO-RAM)is proposed to highlight the critical feature regions and inhibit useless and fake information.Finally,an object detection network based You Only Look Once(YOLO)v2 is established to achieve fast HIF detection and section location.The obtained results from the simulation of the proposed approach on three different distribution networks and one realistic distribution network verify that the proposed method is highly effective in terms of reliability and generalization.展开更多
文摘Ag/AgCl electrode has been prepared using pressed powder techniques. In order to verify the feasibility of this type of electrode used as detecting electric field generated by vessels in seawater, its characteristics of DC resistance, low frequency AC impedance, and receiving impedance in artificial seawater have been studied by polarization measurements, low frequency electrochemical impedance spectra, the open and short circuit cell conditions. The results show that the electrode can keep a low resistance when it responses the weak electrostatic field in seawater. The AC impedance of the electrode decreases as the frequency of the signal increasing. The receiving impedance decreases when the frequency of external field increases too. The valid detection bandwidth is determined by the properties of the impedance and the reactions occurring on the surface of the electrode.
基金supported by the National Key Research and Development Program of China(2017YFB0902800)Science and Technology Project of the State Grid Corporation of China(52094017003D).
文摘Detection of high impedance faults(HIFs)has been traditionally a main challenge in the protection of distribution systems,since they do not generate enough current to be reliably detected by conventional over-current relays.Data-based methods are alternative HIF detection methods which avoid threshold settings by training a classification or regression model.However,most of them lack interpretability and are not compatible with various distribution networks.This paper proposes an object detection-based HIF detection method,which has higher visualization and can be easily applied to different scenarios.First,based on the analysis of HIFs,a Butterworth band-pass filter is designed for HIF harmonic feature extraction.Subsequently,based on the synchronized data provided by distribution-level phasor measurement units,global HIF feature gray-scale images are formed through combining the topology information of the distribution network.To further enhance the feature information,a locally excitatory globally inhibitory oscillator region attention mechanism(LEGIO-RAM)is proposed to highlight the critical feature regions and inhibit useless and fake information.Finally,an object detection network based You Only Look Once(YOLO)v2 is established to achieve fast HIF detection and section location.The obtained results from the simulation of the proposed approach on three different distribution networks and one realistic distribution network verify that the proposed method is highly effective in terms of reliability and generalization.