This paper presents a wide-bandwidth back-illuminated modified uni-traveling-carrier photodiode(MUTC-PD)packaged with standard WR-5 rectangular waveguide for high-speed wireless communications.With optimized epitaxy s...This paper presents a wide-bandwidth back-illuminated modified uni-traveling-carrier photodiode(MUTC-PD)packaged with standard WR-5 rectangular waveguide for high-speed wireless communications.With optimized epitaxy structure and coplanar waveguide electrodes,the fabricated 4-μm-diameter PD exhibits ultra-flat frequency response and high saturation power.Integrated passive circuits including low-loss bias-tee and E-plane probe are designed to package the PD into a compact module with waveguide output.The packaged PD module has demonstrated a flat frequency response with fluctuations within±2.75 d B over a broadband of 140–220 GHz and a high saturated output power of-7.8 d Bm(166μW)at 140 GHz.For wireless communication applications,the packaged PD is used to implement 1-m free space transmission at carrier frequencies of 150.5 and 210.5 GHz,with transmission rates of 75 and 90 Gbps,respectively.展开更多
Multilayer interference mirrors play a pivotal role in spectroscopic diagnostic systems,which probe electron temperature and density during inertial confinement fusion processes.In this study,aperiodic Mo/B_(4)C multi...Multilayer interference mirrors play a pivotal role in spectroscopic diagnostic systems,which probe electron temperature and density during inertial confinement fusion processes.In this study,aperiodic Mo/B_(4)C multilayer mirrors of varied thick-nesses were investigated for X-ray plasma diagnostics at the 9.67-keV W-Lβline.The thickness distribution of the aperiodic multilayers was designed using the first Bragg diffraction condition and then optimized through a simplex algorithm to realize a narrow bandwidth and consistent spectral response.To enhance spectral accuracy,further refinements were undertaken by matching the grazing incidence X-ray reflectivity data with actual structural parameters.X-ray reflectivity measurements from the SSRF synchrotron radiation facility on the optimized sample showed a reflectivity of 29.7±2.6%,flat-band range of 1.3 keV,and bandwidth of 1.7 keV,making it suitable for high-temperature plasma diagnostics.The study explored the potential of predicting the 9.67 keV reflectivity spectrum using the fitting data from the grazing incidence X-ray reflectivity curves at 8.05 keV.Additionally,the short-term thermal stability of an aperiodic multilayer was assessed using temperature-dependent in situ X-ray measurements.Shifts in the reflectivity spectrum during annealing were attributed to interdiffusion and interfacial relaxation.The research team recommends the aperiodic Mo/B_(4)C multilayer mirror for operations below 300℃.展开更多
Objective:The accurate prediction of tumor response to neoadjuvant chemoradiotherapy(nCRT)remains challenging.Few studies have investigated pathologic complete response(ypCR)prediction in patients with residual flat m...Objective:The accurate prediction of tumor response to neoadjuvant chemoradiotherapy(nCRT)remains challenging.Few studies have investigated pathologic complete response(ypCR)prediction in patients with residual flat mucosal lesions after treatment.This study aimed to identify variables for predicting ypCR in patients with residual flat mucosal lesions after nCRT for locally advanced rectal cancer(LARC).Methods:Data of patients with residual flat mucosal lesions after nCRT who underwent radical resection between 2009 and 2015 were retrospectively collected from the LARC database at Peking University Cancer Hospital.Univariate and multivariate analyses of the association between clinicopathological factors and ypCR were performed,and a nomogram was constructed by incorporating the significant predictors.Results:Of the 246 patients with residual flat mucosal lesions included in the final analysis,56(22.8%)had ypCR.Univariate and multivariate analyses showed that pretreatment cT stage(pre-cT)≤T2(P=0.016),magnetic resonance tumor regression grade(MR-TRG)1-3(P=0.001)and residual mucosal lesion depth=0 mm(P<0.001)were associated with a higher rate of ypCR.A nomogram was developed with a concordance index(C-index)of0.759 and the calibration curve showed that the nomogram model had good predictive consistency.The follow-up time ranged from 3.0 to 113.3 months,with a median follow-up time of 63.77 months.The multivariate Cox regression model showed that the four variables in the nomogram model were not risk factors for disease-free survival(DFS)or overall survival(OS).Conclusions:Completely flat mucosa,early cT stage and good MR-TRG were predictive factors for ypCR instead of DFS or OS in patients with LARC with residual flat mucosal lesions after nCRT.Endoscopic mucosal re-evaluation before surgery is important,as it may contribute to decision-making and facilitate nonoperative management or organ preservation.展开更多
We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of ...We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient.展开更多
We report a theoretical study of a broadband Si/graded-SiGe/Ge/Ge0.9Sn0.1 p–i–n photodetector with a flat response based on modulating thickness of the layers in the active region.The responsivity of the photodetect...We report a theoretical study of a broadband Si/graded-SiGe/Ge/Ge0.9Sn0.1 p–i–n photodetector with a flat response based on modulating thickness of the layers in the active region.The responsivity of the photodetector is about 0.57 A/W in the range of 700 to 1800 nm.This structure is suitable for silicon-based epitaxial growth.Annealing is technically applied to form the graded-SiGe.The photodetector reaches a cut-off wavelength at^2300 nm and a low dark-current density under 3 V reverse bias about 0.17 mA/cm^2 is achieved theoretical at room temperature.This work is of great significance for silicon-based detection and communication,from visible to infrared.展开更多
基金supported in part by National Key Research and Development Program of China(No.2022YFB2803002)National Natural Science Foundation of China(Nos.62235005,62127814,62225405,61975093,61927811,61991443,61925104 and 61974080)Collaborative Innovation Centre of Solid-State Lighting and Energy-Saving Electronics.
文摘This paper presents a wide-bandwidth back-illuminated modified uni-traveling-carrier photodiode(MUTC-PD)packaged with standard WR-5 rectangular waveguide for high-speed wireless communications.With optimized epitaxy structure and coplanar waveguide electrodes,the fabricated 4-μm-diameter PD exhibits ultra-flat frequency response and high saturation power.Integrated passive circuits including low-loss bias-tee and E-plane probe are designed to package the PD into a compact module with waveguide output.The packaged PD module has demonstrated a flat frequency response with fluctuations within±2.75 d B over a broadband of 140–220 GHz and a high saturated output power of-7.8 d Bm(166μW)at 140 GHz.For wireless communication applications,the packaged PD is used to implement 1-m free space transmission at carrier frequencies of 150.5 and 210.5 GHz,with transmission rates of 75 and 90 Gbps,respectively.
基金This work was supported by the National Natural Science Foundation of China(NSFC)(Nos.11875204 and U1932167)Fundamental Research Funds for the Central Universities(Nos.22120210446 and 22120180070)the Presidential Foundation of China Academy of Engineering Physics(No.YZJJLX2019011).
文摘Multilayer interference mirrors play a pivotal role in spectroscopic diagnostic systems,which probe electron temperature and density during inertial confinement fusion processes.In this study,aperiodic Mo/B_(4)C multilayer mirrors of varied thick-nesses were investigated for X-ray plasma diagnostics at the 9.67-keV W-Lβline.The thickness distribution of the aperiodic multilayers was designed using the first Bragg diffraction condition and then optimized through a simplex algorithm to realize a narrow bandwidth and consistent spectral response.To enhance spectral accuracy,further refinements were undertaken by matching the grazing incidence X-ray reflectivity data with actual structural parameters.X-ray reflectivity measurements from the SSRF synchrotron radiation facility on the optimized sample showed a reflectivity of 29.7±2.6%,flat-band range of 1.3 keV,and bandwidth of 1.7 keV,making it suitable for high-temperature plasma diagnostics.The study explored the potential of predicting the 9.67 keV reflectivity spectrum using the fitting data from the grazing incidence X-ray reflectivity curves at 8.05 keV.Additionally,the short-term thermal stability of an aperiodic multilayer was assessed using temperature-dependent in situ X-ray measurements.Shifts in the reflectivity spectrum during annealing were attributed to interdiffusion and interfacial relaxation.The research team recommends the aperiodic Mo/B_(4)C multilayer mirror for operations below 300℃.
基金supported by grants from the National Natural Science Foundation of China(No.82173156)Beijing Hospitals Authority Clinical Medicine Development of Special Funding Support(No.ZYLX202116)。
文摘Objective:The accurate prediction of tumor response to neoadjuvant chemoradiotherapy(nCRT)remains challenging.Few studies have investigated pathologic complete response(ypCR)prediction in patients with residual flat mucosal lesions after treatment.This study aimed to identify variables for predicting ypCR in patients with residual flat mucosal lesions after nCRT for locally advanced rectal cancer(LARC).Methods:Data of patients with residual flat mucosal lesions after nCRT who underwent radical resection between 2009 and 2015 were retrospectively collected from the LARC database at Peking University Cancer Hospital.Univariate and multivariate analyses of the association between clinicopathological factors and ypCR were performed,and a nomogram was constructed by incorporating the significant predictors.Results:Of the 246 patients with residual flat mucosal lesions included in the final analysis,56(22.8%)had ypCR.Univariate and multivariate analyses showed that pretreatment cT stage(pre-cT)≤T2(P=0.016),magnetic resonance tumor regression grade(MR-TRG)1-3(P=0.001)and residual mucosal lesion depth=0 mm(P<0.001)were associated with a higher rate of ypCR.A nomogram was developed with a concordance index(C-index)of0.759 and the calibration curve showed that the nomogram model had good predictive consistency.The follow-up time ranged from 3.0 to 113.3 months,with a median follow-up time of 63.77 months.The multivariate Cox regression model showed that the four variables in the nomogram model were not risk factors for disease-free survival(DFS)or overall survival(OS).Conclusions:Completely flat mucosa,early cT stage and good MR-TRG were predictive factors for ypCR instead of DFS or OS in patients with LARC with residual flat mucosal lesions after nCRT.Endoscopic mucosal re-evaluation before surgery is important,as it may contribute to decision-making and facilitate nonoperative management or organ preservation.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11405158 and 11775203)the Presidential Foundation of China Academy of Engineering Physics(Grant No.YZJJLX 2016007)
文摘We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient.
基金This work was supported by National Basic Research Program of China(No.2013CB632103)National Natural Science Foundation of China(Nos.61534005 and 61474081)Scientific Research Project of Fujian Provincial Department of Education(No.JA15651).
文摘We report a theoretical study of a broadband Si/graded-SiGe/Ge/Ge0.9Sn0.1 p–i–n photodetector with a flat response based on modulating thickness of the layers in the active region.The responsivity of the photodetector is about 0.57 A/W in the range of 700 to 1800 nm.This structure is suitable for silicon-based epitaxial growth.Annealing is technically applied to form the graded-SiGe.The photodetector reaches a cut-off wavelength at^2300 nm and a low dark-current density under 3 V reverse bias about 0.17 mA/cm^2 is achieved theoretical at room temperature.This work is of great significance for silicon-based detection and communication,from visible to infrared.