Precise and sensitive bioanalysis has been the major and urgent pursuit in pathologic diagnosis,food safety,environment monitoring,and drug evaluation.Photoelectrochemical(PEC)bioanalysis,as one of the most promising ...Precise and sensitive bioanalysis has been the major and urgent pursuit in pathologic diagnosis,food safety,environment monitoring,and drug evaluation.Photoelectrochemical(PEC)bioanalysis,as one of the most promising detection technologies,has rapidly expanded within the field of analysis.However,most of reported PEC analysis approaches still suffer from weak external anti-interference ability,high background,and the risk of false positive or negative errors due to their inherent single-signal readout.To overcome these shortcomings,new PEC-coupled dual-modal analysis approaches have been developed,where a dual-response signal can be derived through two completely different mechanisms and independent signal transduction pathways.This review introduces the basic principles of PEC biosensing and enumerates and classifies the substrate or probe selections,constructions,and applications of PEC-coupled dual-modal biosensors.Furthermore,the challenges and developmental prospects of PEC-coupled dual-mode sensing technologies are evaluated and discussed.We hope that this review will provide valuable insights into the latest advancements and practical applications of dual-mode PEC bioanalysis,which will be of great interest to those seeking to stay informed in this field.展开更多
By using polarization resistance measurement and electrochemical impedance spectroscopy(EIS),in field corrosion electrochemical detections of Q235 carbon steel and Q235 ultrafine grained steel immersed samples in Zhou...By using polarization resistance measurement and electrochemical impedance spectroscopy(EIS),in field corrosion electrochemical detections of Q235 carbon steel and Q235 ultrafine grained steel immersed samples in Zhoushan Marine Corrosion Test Station were performed for 4 years.Dynamic corrosion data during exposure were obtained.Electrochemical detection results reflected not only the corrosion modalities and corrosion rates of the samples,but also the direct influence of marine environmental factors on the corrosion behavior.Seawater temperature was the major factor influencing the corrosion behaviors of carbon steels,and corrosion rates of these samples increased with increasing seawater temperature.The influence of seawater velocity and orientation of flow was less than that of temperature.展开更多
基金the National Natural Science Foundation of China(Nos.52303153 and 51873145)the Basic science(Natural science)research project in universities of Jiangsu Province(No.23KJB150035)+2 种基金the Excellent Youth Foundation of Jiangsu Scientific Committee(No.BK20170065)the Qing Lan Project,the 5th 333 High-level Talents Training Project of Jiangsu Province(No.BRA2018340)the Six Talent Peaks Project in Jiangsu Province(No.XCL-79).
文摘Precise and sensitive bioanalysis has been the major and urgent pursuit in pathologic diagnosis,food safety,environment monitoring,and drug evaluation.Photoelectrochemical(PEC)bioanalysis,as one of the most promising detection technologies,has rapidly expanded within the field of analysis.However,most of reported PEC analysis approaches still suffer from weak external anti-interference ability,high background,and the risk of false positive or negative errors due to their inherent single-signal readout.To overcome these shortcomings,new PEC-coupled dual-modal analysis approaches have been developed,where a dual-response signal can be derived through two completely different mechanisms and independent signal transduction pathways.This review introduces the basic principles of PEC biosensing and enumerates and classifies the substrate or probe selections,constructions,and applications of PEC-coupled dual-modal biosensors.Furthermore,the challenges and developmental prospects of PEC-coupled dual-mode sensing technologies are evaluated and discussed.We hope that this review will provide valuable insights into the latest advancements and practical applications of dual-mode PEC bioanalysis,which will be of great interest to those seeking to stay informed in this field.
文摘By using polarization resistance measurement and electrochemical impedance spectroscopy(EIS),in field corrosion electrochemical detections of Q235 carbon steel and Q235 ultrafine grained steel immersed samples in Zhoushan Marine Corrosion Test Station were performed for 4 years.Dynamic corrosion data during exposure were obtained.Electrochemical detection results reflected not only the corrosion modalities and corrosion rates of the samples,but also the direct influence of marine environmental factors on the corrosion behavior.Seawater temperature was the major factor influencing the corrosion behaviors of carbon steels,and corrosion rates of these samples increased with increasing seawater temperature.The influence of seawater velocity and orientation of flow was less than that of temperature.