Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of ...Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of high voltage IGBT modules are insufficient;for example,partial discharge resistance under DC voltage blocking condition is not considered.In this paper,a new test was proposed to allow the measurement of partial discharges in all the components of IGBT modules under DC voltage.The topology of the measuring circuit is arranged in the polarity discrimination way to exclude the interference,and the voltage and discharge current waveforms during the partial discharge process are measured by the wideband time domain measurement technique.According to the proposed test,the discharge phenomenon of the IGBT modules below the rating voltage were detected.A comprehensive waveform analysis on the voltage and discharge current was performed,and the influence of the applied voltage on the waveform parameters was obtained.The waveform parameters are influenced by the applied voltage and insulation structure,which enables the discrimination of the causes of the observed partial discharge in the IGBT module under DC voltage by the waveform analysis technique.Based on the waveform analysis technique,the types and causes of the observed partial discharges were discussed and inferred,and the correctness of the inference was further verified by observation.The proposed test and waveform analysis technique provide the possibility to evaluate and distinguish partial discharges in the high voltage IGBT module under DC voltage,which may be helpful to insulation performance evaluation and insulation defect diagnosis in high voltage IGBT module.展开更多
Measuring the pre-breakdown current of long sparks in air is important for investigating the discharge mechanism.Since the breakdown of long air gaps is conducted by a series of streamer-leader processes,the correspon...Measuring the pre-breakdown current of long sparks in air is important for investigating the discharge mechanism.Since the breakdown of long air gaps is conducted by a series of streamer-leader processes,the corresponding current signals cover a bandwidth of 0 to more than 20 MHz.Measurement accuracy of the current from the high voltage side is affected by the displacement current and impulse electromagnetic interference.In this paper,a coaxial current sensor with a DC bandwidth of 74.45 MHz is developed.A displacement current-restrained electrode structure is proposed to reduce the equivalent capacitance between the current sensor and the ground over 30 times.Combined with the digital optical fiber synchronous acquisition unit,a current measurement system for long air gap discharge is established.For the purpose of the UHV system’s external insulation optimization design,the discharge current waveform of a 6 m rod-plane air gap under positive switching impulse voltage with 250µs and 1000µs time to crest is obtained.Discharge images and stressed voltage are combined to analyze the continuous feature of a current waveform under critical time to crest impulse and discontinuous feature under long front duration impulse.For the purposes of a lightning protection study,the current waveform of a 10 m rod-plane air gap is subjected to negative switching impulse.Finally,the pulse characteristics of the current corresponding to the single channel and branching stepped negative leader are discussed.展开更多
基金This work was supported by the National Natural Science Foundation of China-State Grid Corporation Joint Fund for Smart Grid(No.U1766219)the Fundamental Research Funds for the Central Universities(No.2017XS027).
文摘Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of high voltage IGBT modules are insufficient;for example,partial discharge resistance under DC voltage blocking condition is not considered.In this paper,a new test was proposed to allow the measurement of partial discharges in all the components of IGBT modules under DC voltage.The topology of the measuring circuit is arranged in the polarity discrimination way to exclude the interference,and the voltage and discharge current waveforms during the partial discharge process are measured by the wideband time domain measurement technique.According to the proposed test,the discharge phenomenon of the IGBT modules below the rating voltage were detected.A comprehensive waveform analysis on the voltage and discharge current was performed,and the influence of the applied voltage on the waveform parameters was obtained.The waveform parameters are influenced by the applied voltage and insulation structure,which enables the discrimination of the causes of the observed partial discharge in the IGBT module under DC voltage by the waveform analysis technique.Based on the waveform analysis technique,the types and causes of the observed partial discharges were discussed and inferred,and the correctness of the inference was further verified by observation.The proposed test and waveform analysis technique provide the possibility to evaluate and distinguish partial discharges in the high voltage IGBT module under DC voltage,which may be helpful to insulation performance evaluation and insulation defect diagnosis in high voltage IGBT module.
基金supported by the Fund of the National Basic Research of China(2011CB 209403).
文摘Measuring the pre-breakdown current of long sparks in air is important for investigating the discharge mechanism.Since the breakdown of long air gaps is conducted by a series of streamer-leader processes,the corresponding current signals cover a bandwidth of 0 to more than 20 MHz.Measurement accuracy of the current from the high voltage side is affected by the displacement current and impulse electromagnetic interference.In this paper,a coaxial current sensor with a DC bandwidth of 74.45 MHz is developed.A displacement current-restrained electrode structure is proposed to reduce the equivalent capacitance between the current sensor and the ground over 30 times.Combined with the digital optical fiber synchronous acquisition unit,a current measurement system for long air gap discharge is established.For the purpose of the UHV system’s external insulation optimization design,the discharge current waveform of a 6 m rod-plane air gap under positive switching impulse voltage with 250µs and 1000µs time to crest is obtained.Discharge images and stressed voltage are combined to analyze the continuous feature of a current waveform under critical time to crest impulse and discontinuous feature under long front duration impulse.For the purposes of a lightning protection study,the current waveform of a 10 m rod-plane air gap is subjected to negative switching impulse.Finally,the pulse characteristics of the current corresponding to the single channel and branching stepped negative leader are discussed.