Plasma Synthetic Jet(PSJ) actuators have shown wide and promising application prospects in high-speed flow control, due to their advantages including high exhaust speed, wide frequency band, rapid response, and non-mo...Plasma Synthetic Jet(PSJ) actuators have shown wide and promising application prospects in high-speed flow control, due to their advantages including high exhaust speed, wide frequency band, rapid response, and non-moving components. Although previous studies on PSJ actuators are abundant, most of them have focused on the performance of a single actuator. However, in practice, an actuator array is very necessary for large-scale aerodynamic actuation on account of the small affected area of a single PSJ. In this paper, the characteristics of a twoelectrode plasma synthetic jet actuator array in serial are investigated experimentally. Compared to a parallel actuator array, the serial actuator array requires simpler power supply design and is much easier to realize. High-speed photography of the discharge evolution, voltage-current measurement, and shadowgraphy visualization are used in the investigation. Experimental results show that, for the serial actuator array, weak discharges happen firstly between energized and suspending electrodes, and then a strong pulse arc discharge is triggered. The breakdown voltage in serial is irrelevant to such factors as the number of actuators, the maximum or minimum gap in serial,the connection sequence, etc. It is mainly determined by the sum of gaps. For serial actuators with the same anode-to-cathode spacing, the energy deposition is the same, and the jet is synchronous and similar. Because of the entrainment and merging of adjacent jet vortices, the jet front speed of an aligned synchronous jet array increases as the orifice distance decreases. To achieve the highest jet front velocity, the orifice of the actuator has an optimal diameter.展开更多
Obtaining a reliable discharge of particulate solids from a storage silo is a prerequisite to securing oper- ational adequacy in solids handling processes. If a silo is poorly designed, an unreliable interrupted disch...Obtaining a reliable discharge of particulate solids from a storage silo is a prerequisite to securing oper- ational adequacy in solids handling processes. If a silo is poorly designed, an unreliable interrupted discharge often occurs. In this study, an in-house finite element (FE) program was modified to predict the particulate solids flow patterns during discharges from silos, and the effect of a double-cone insert on such flow patterns. In FE modeling, a Eulerian approach was adopted with an assumption of steady-state flow-a state that greatly facilitated investigations on the effects of double-cone inserts on the flow of particulate solids. Predictions were carried out on whether the discharge was in mass flow or funnel flow, associated with the inclination angle of the silo's hopper. Predicted results were in agreement with the Jenike Chart, and proved that an upper lateral pressure ratio value gave a better critical hopper half angle to achieve mass flow (EN 1991-4, 2006). The shape and size of the stagnant zone were further discussed to address the flow channel boundary between the flowing and static solids if the discharge was in a funnel pattern. Results also showed the effects of a double-cone insert on the flow patterns which con- verted silos from funnel flow to mass flow up to a certain hopper inclination angle and would improve the flow pattern even for shallower angles. Experiments were carried out to verify some of the predicted results. Some qualitative comparisons were made between the predicted results and experimental mea- surements, which indicated that further efforts are needed in predicting the shape of the stagnant zone (flow channel boundary) during funnel flow discharges.展开更多
A 15° swept wing with dielectric barrier discharge plasma actuator is designed. Experimental study of flow separation control with nanosecond pulsed plasma actuation is performed at flow velocity up to 40 m/s. Th...A 15° swept wing with dielectric barrier discharge plasma actuator is designed. Experimental study of flow separation control with nanosecond pulsed plasma actuation is performed at flow velocity up to 40 m/s. The effects of the actuation frequency and voltage on the aerodynamic performance of the swept wing are evaluated by the balanced force and pressure measurements in the wind tunnel. At last, the performances on separation flow control of the three types of actuators with plane and saw-toothed exposed electrodes are compared. The optimal actua- tion frequency for the flow separation control on the swept wing is detected, namely the reduced frequency is 0.775, which is different from 2-D airfoil separation control. There exists a threshold voltage for the low swept wing flow control. Before the threshold voltage, as the actuation voltage increases, the control effects become better. The maximum lift is increased by 23.1% with the drag decreased by 22.4% at 14°, compared with the base line. However, the best effects are obtained on actuator with plane exposed electrode in the low-speed experiment and the abilities of saw-toothed actuators are expected to be verified under high-speed conditions.展开更多
基金supported by the National Natural Science Foundation of China(Nos.11372349,11502295,and11572349)
文摘Plasma Synthetic Jet(PSJ) actuators have shown wide and promising application prospects in high-speed flow control, due to their advantages including high exhaust speed, wide frequency band, rapid response, and non-moving components. Although previous studies on PSJ actuators are abundant, most of them have focused on the performance of a single actuator. However, in practice, an actuator array is very necessary for large-scale aerodynamic actuation on account of the small affected area of a single PSJ. In this paper, the characteristics of a twoelectrode plasma synthetic jet actuator array in serial are investigated experimentally. Compared to a parallel actuator array, the serial actuator array requires simpler power supply design and is much easier to realize. High-speed photography of the discharge evolution, voltage-current measurement, and shadowgraphy visualization are used in the investigation. Experimental results show that, for the serial actuator array, weak discharges happen firstly between energized and suspending electrodes, and then a strong pulse arc discharge is triggered. The breakdown voltage in serial is irrelevant to such factors as the number of actuators, the maximum or minimum gap in serial,the connection sequence, etc. It is mainly determined by the sum of gaps. For serial actuators with the same anode-to-cathode spacing, the energy deposition is the same, and the jet is synchronous and similar. Because of the entrainment and merging of adjacent jet vortices, the jet front speed of an aligned synchronous jet array increases as the orifice distance decreases. To achieve the highest jet front velocity, the orifice of the actuator has an optimal diameter.
文摘Obtaining a reliable discharge of particulate solids from a storage silo is a prerequisite to securing oper- ational adequacy in solids handling processes. If a silo is poorly designed, an unreliable interrupted discharge often occurs. In this study, an in-house finite element (FE) program was modified to predict the particulate solids flow patterns during discharges from silos, and the effect of a double-cone insert on such flow patterns. In FE modeling, a Eulerian approach was adopted with an assumption of steady-state flow-a state that greatly facilitated investigations on the effects of double-cone inserts on the flow of particulate solids. Predictions were carried out on whether the discharge was in mass flow or funnel flow, associated with the inclination angle of the silo's hopper. Predicted results were in agreement with the Jenike Chart, and proved that an upper lateral pressure ratio value gave a better critical hopper half angle to achieve mass flow (EN 1991-4, 2006). The shape and size of the stagnant zone were further discussed to address the flow channel boundary between the flowing and static solids if the discharge was in a funnel pattern. Results also showed the effects of a double-cone insert on the flow patterns which con- verted silos from funnel flow to mass flow up to a certain hopper inclination angle and would improve the flow pattern even for shallower angles. Experiments were carried out to verify some of the predicted results. Some qualitative comparisons were made between the predicted results and experimental mea- surements, which indicated that further efforts are needed in predicting the shape of the stagnant zone (flow channel boundary) during funnel flow discharges.
基金founded by National Natural Science Foundation of China under contract Nos. 51336011, 51276197, and 51207169
文摘A 15° swept wing with dielectric barrier discharge plasma actuator is designed. Experimental study of flow separation control with nanosecond pulsed plasma actuation is performed at flow velocity up to 40 m/s. The effects of the actuation frequency and voltage on the aerodynamic performance of the swept wing are evaluated by the balanced force and pressure measurements in the wind tunnel. At last, the performances on separation flow control of the three types of actuators with plane and saw-toothed exposed electrodes are compared. The optimal actua- tion frequency for the flow separation control on the swept wing is detected, namely the reduced frequency is 0.775, which is different from 2-D airfoil separation control. There exists a threshold voltage for the low swept wing flow control. Before the threshold voltage, as the actuation voltage increases, the control effects become better. The maximum lift is increased by 23.1% with the drag decreased by 22.4% at 14°, compared with the base line. However, the best effects are obtained on actuator with plane exposed electrode in the low-speed experiment and the abilities of saw-toothed actuators are expected to be verified under high-speed conditions.