Symmetrical monopolar configuration is the prevailing scheme configuration for modular multilevel converter based high-voltage direct current(MMC-HVDC) links, in which severe DC overvoltage or overcurrent can be cause...Symmetrical monopolar configuration is the prevailing scheme configuration for modular multilevel converter based high-voltage direct current(MMC-HVDC) links, in which severe DC overvoltage or overcurrent can be caused by the DC faults. To deal with the possible asymmetry in the DC faults and the coupling effects of the DC lines, this paper analyzes the DC fault characteristics based on the phase-mode transformation. First, the DC grid is decomposed into the common-mode and the differential-mode networks. The equivalent models of the MMCs and DC lines in the two networks are derived, respectively. Then, based on the state matrices, a unified numerical calculation method for the fault voltages and currents at the DC side is proposed. Compared with the time-domain simulations performed on PSCAD/EMTDC, the accuracy of the proposed method is validated. Last, the system parameter analysis shows that the grounding parameters play an important role in reducing the severity of the pole-to-ground faults, whereas the coupling effects of the DC lines should be considered when calculating the DC fault currents associated with the pole-to-pole faults.展开更多
基于高温超导(High Temperature Superconductivity,HTS)直流感应加热技术加热质量好、加热效率高等优点,提出一种基于圆筒形多极直流电机结构的对极铁芯高温超导直流感应加热装置.首先,针对加热装置气隙磁场与铝棒温升特性,采用麦克斯...基于高温超导(High Temperature Superconductivity,HTS)直流感应加热技术加热质量好、加热效率高等优点,提出一种基于圆筒形多极直流电机结构的对极铁芯高温超导直流感应加热装置.首先,针对加热装置气隙磁场与铝棒温升特性,采用麦克斯韦方程组与法拉第电磁感应定律,并结合固体热传导方程,建立铝棒加热过程数值模型;其次,兼顾加热装置环形铁芯与直流电机多极结构模式,构建4极与2极电磁模型与热模型;再次,针对铝棒电导率、转速以及长度对铝棒加热过程的影响,利用对极加热装置电磁热模型,研究铝棒内涡流与加热功率的变化过程;最后,针对加热区域磁场强度不足的问题,基于直流电机极靴长度对气隙磁场大小的影响,提出极靴结构改善气隙磁场模型.研究结果表明:2极铁芯结构下铝棒最大磁通密度高于4极结构0.16 T,铝棒最大温度高于4极结构54 K;铝棒内涡流密度和加热功率与铝棒电导率、长度以及转速呈正相关性;极靴结构提高了铝棒磁通密度0.11 T,铝棒温度提升了4.2℃.展开更多
The fault current level analysis is important for bipolar direct current(DC)grids,which determines the operation and protection requirements.The DC grid topology significantly impacts the current path and then the fau...The fault current level analysis is important for bipolar direct current(DC)grids,which determines the operation and protection requirements.The DC grid topology significantly impacts the current path and then the fault current level of the grid,which makes it possible to limit the fault current by optimizing the grid topology.However,the corresponding discussion in the literature is indigent.Aiming at this point,the impact of grid topology,i.e.,the connecting scheme of converters,on the pole-to-ground fault current in bipolar DC grids,is investigated in this paper,and the ground-return-based and metallic-return-based grounding schemes are considered,respectively.Firstly,the decoupled equivalent model in frequency domain for fault current analysis is obtained.Then,the impacts of converters with different distances to the fault point on the fault current can be analyzed according to the high-frequency impedance characteristics.Based on the analysis results,a simplified fault current index(SFCI)is proposed to realize the fast evaluation of impact of grid topology on the fault current level.The SFCI is then applied to evaluate the relative fault current level.Finally,the simulation results validate the model,the analysis method,and the SFCI,which can effectively evaluate the relative fault current level in a direct and fast manner.展开更多
As the structures of multiple branch lines(MBLs)will be widely applied in the future flexible DC distribution network,there is a urgent need for improving system reliability by tackling the frequent non-permanent pole...As the structures of multiple branch lines(MBLs)will be widely applied in the future flexible DC distribution network,there is a urgent need for improving system reliability by tackling the frequent non-permanent pole-to-pole(P-P)fault on distribution lines.A novel fault restoration strategy based on local information is proposed to solve this issue.The strategy firstly splits a double-ended power supply network into two single-ended power supply networks through the timing difference characteristics of a hybrid direct current circuit breaker(HDCCB)entering the recloser.Then,a method based on the characteristic of the transient energy of fault current is proposed to screen the faulty branch line in each single-ended power supply network.Also,a four-terminal flexible DC distribution network with MBLs is constructed on PSCAD to demonstrate the efficacy of the proposed strategy.Various factors such as noise,fault location,and DC arc equivalent resistance are considered in the simulation model for testing.Test results prove that the proposed strategy for fault restoration is effective,and features high performance and scalability.展开更多
This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system...This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system protection and control. Firstly, the transient behavior is analyzed and the conduction overlap- ping angle γ, is defined. Secondly, seven possible short-circuit current paths induced by different γ values are identified, and the corresponding engineering short-circuit current calculation methods for both AC and DC sides are proposed. And then, the influences of impedance distribution factor κ and equivalent short-circuit resistance Rsc on short-circuit currents are elaborated the proposed analysis methods. Finally, case study is used to verify the effectiveness of展开更多
文摘Symmetrical monopolar configuration is the prevailing scheme configuration for modular multilevel converter based high-voltage direct current(MMC-HVDC) links, in which severe DC overvoltage or overcurrent can be caused by the DC faults. To deal with the possible asymmetry in the DC faults and the coupling effects of the DC lines, this paper analyzes the DC fault characteristics based on the phase-mode transformation. First, the DC grid is decomposed into the common-mode and the differential-mode networks. The equivalent models of the MMCs and DC lines in the two networks are derived, respectively. Then, based on the state matrices, a unified numerical calculation method for the fault voltages and currents at the DC side is proposed. Compared with the time-domain simulations performed on PSCAD/EMTDC, the accuracy of the proposed method is validated. Last, the system parameter analysis shows that the grounding parameters play an important role in reducing the severity of the pole-to-ground faults, whereas the coupling effects of the DC lines should be considered when calculating the DC fault currents associated with the pole-to-pole faults.
基金supported by the Science and Technology Project of State Grid Corporation of China“Cloud energy storage framework-based AI dispatching strategy of renewable energy integration and contingency response” (No.5100-202199274A-0-0-00)。
文摘The fault current level analysis is important for bipolar direct current(DC)grids,which determines the operation and protection requirements.The DC grid topology significantly impacts the current path and then the fault current level of the grid,which makes it possible to limit the fault current by optimizing the grid topology.However,the corresponding discussion in the literature is indigent.Aiming at this point,the impact of grid topology,i.e.,the connecting scheme of converters,on the pole-to-ground fault current in bipolar DC grids,is investigated in this paper,and the ground-return-based and metallic-return-based grounding schemes are considered,respectively.Firstly,the decoupled equivalent model in frequency domain for fault current analysis is obtained.Then,the impacts of converters with different distances to the fault point on the fault current can be analyzed according to the high-frequency impedance characteristics.Based on the analysis results,a simplified fault current index(SFCI)is proposed to realize the fast evaluation of impact of grid topology on the fault current level.The SFCI is then applied to evaluate the relative fault current level.Finally,the simulation results validate the model,the analysis method,and the SFCI,which can effectively evaluate the relative fault current level in a direct and fast manner.
基金supported by the National Natural Science Foundation of China(No.51877174)。
文摘As the structures of multiple branch lines(MBLs)will be widely applied in the future flexible DC distribution network,there is a urgent need for improving system reliability by tackling the frequent non-permanent pole-to-pole(P-P)fault on distribution lines.A novel fault restoration strategy based on local information is proposed to solve this issue.The strategy firstly splits a double-ended power supply network into two single-ended power supply networks through the timing difference characteristics of a hybrid direct current circuit breaker(HDCCB)entering the recloser.Then,a method based on the characteristic of the transient energy of fault current is proposed to screen the faulty branch line in each single-ended power supply network.Also,a four-terminal flexible DC distribution network with MBLs is constructed on PSCAD to demonstrate the efficacy of the proposed strategy.Various factors such as noise,fault location,and DC arc equivalent resistance are considered in the simulation model for testing.Test results prove that the proposed strategy for fault restoration is effective,and features high performance and scalability.
文摘This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system protection and control. Firstly, the transient behavior is analyzed and the conduction overlap- ping angle γ, is defined. Secondly, seven possible short-circuit current paths induced by different γ values are identified, and the corresponding engineering short-circuit current calculation methods for both AC and DC sides are proposed. And then, the influences of impedance distribution factor κ and equivalent short-circuit resistance Rsc on short-circuit currents are elaborated the proposed analysis methods. Finally, case study is used to verify the effectiveness of