In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for th...In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, con-structing 3D truck models, tracking vehicles in real time using a 3D interface and indicating available escape routes for driver safety.展开更多
Background: The ExcelsiusGPS?(Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicl...Background: The ExcelsiusGPS?(Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS?robotic system and describe a novel metric to quantify screw deviation. Methods: Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS?surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Results: Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8-5.2 mm), mean tail deviation was 3.2 mm (range 0.9-5.4 mm), and mean angular offset was 2.4 degrees (range 0.7-3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. Conclusion: The ExcelsiusGPS? robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology.展开更多
GIS applications to mobile devices are becoming i nc reasingly popular, utilizing a di-verserange of devices. Many of these devices suffer from serious constraints in three main areas: processor speed, memory space an...GIS applications to mobile devices are becoming i nc reasingly popular, utilizing a di-verserange of devices. Many of these devices suffer from serious constraints in three main areas: processor speed, memory space and screen size. This paper presents a GIS application, called "MacaoMap", that is intended for heavily resource-co nstrained handheld devices. MacaoMap is a tourism-oriented map application of t he Macao territory for PalmOS and Pocket PC personal digital assistants. It was designed to perform satisfactorily on devices with as little as 16 MHz processor speed, and requires only 500 KB available memory for the GIS application and al l GIS data. Memory requirements are kept low through a specially designed data f ormat. The main challenge of satisfactory map drawing speed is addressed through a variety of techniques that were developed for this application. The paper des cribes the application’s data format, outlines the map drawing techniques, and points out the areas for future development.展开更多
基金Financial support for this work, provided by the Key Programs of the National Science and Technology Foundation during the 11th Five-Year Plan Period (No.2006BAK04B04) the State Scholarship Fund (No.2007104096), is gratefully acknowledged
文摘In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, con-structing 3D truck models, tracking vehicles in real time using a 3D interface and indicating available escape routes for driver safety.
文摘Background: The ExcelsiusGPS?(Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS?robotic system and describe a novel metric to quantify screw deviation. Methods: Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS?surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Results: Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8-5.2 mm), mean tail deviation was 3.2 mm (range 0.9-5.4 mm), and mean angular offset was 2.4 degrees (range 0.7-3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. Conclusion: The ExcelsiusGPS? robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology.
文摘GIS applications to mobile devices are becoming i nc reasingly popular, utilizing a di-verserange of devices. Many of these devices suffer from serious constraints in three main areas: processor speed, memory space and screen size. This paper presents a GIS application, called "MacaoMap", that is intended for heavily resource-co nstrained handheld devices. MacaoMap is a tourism-oriented map application of t he Macao territory for PalmOS and Pocket PC personal digital assistants. It was designed to perform satisfactorily on devices with as little as 16 MHz processor speed, and requires only 500 KB available memory for the GIS application and al l GIS data. Memory requirements are kept low through a specially designed data f ormat. The main challenge of satisfactory map drawing speed is addressed through a variety of techniques that were developed for this application. The paper des cribes the application’s data format, outlines the map drawing techniques, and points out the areas for future development.