The dependencies of hot-carrier-induced degradations on the effective channel length Lch,eff are investigated for n-type metal-oxide-semiconductor field effect transistor (MOSFETs). Our experiments find that, with d...The dependencies of hot-carrier-induced degradations on the effective channel length Lch,eff are investigated for n-type metal-oxide-semiconductor field effect transistor (MOSFETs). Our experiments find that, with decreasing Lch,eff, the saturation drain current (Iasat ) degradation is unexpectedly alleviated. The further study demonstrates that the anomalous Lch,eff dependence of Idsat degradation is induced by the increasing influence of the substrate current degradation on the lazar degradation with Lch,eff reducing.展开更多
In this paper, based on the results of tomographic image of Tangshan and Xingtai areas, the relations between thecharacteristics of the two strong earthquake sequences and their three-dimensional velocity structures a...In this paper, based on the results of tomographic image of Tangshan and Xingtai areas, the relations between thecharacteristics of the two strong earthquake sequences and their three-dimensional velocity structures are studied.The research results indicate that:① Mosaic distribution of low-velocity bodies and high-velocity bodies, especially the existence of high-velocity bodies with large size in crust are the common basis of development of thetwo earthquake sequences. ② Scale, depth, and heterogeneity of high-velocity and low-velocity bodies are theimportant factors to effect the characteristic of earthquake sequences. ③ The depth of the high-velocity body inTangshan area is less than that in Xingtai area, which is the principal reason why the dominant focal depth and thebiggest focal depth of Tangshan earthquake sequence are less than Xingtai's. ④ The depth of the high-velocitybodies in Ninghe area is more than that in Tangshan-Luanxian area, which lead to the biggest magnitude and epicentral intensity are lower. These results could be helpful for predicting the main shock of strong swarm-typeearthquakes and later strong aftershocks.展开更多
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista...The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).展开更多
基金Supported by Hong Kong,Macao and Taiwan Science&Technology Cooperation Program of China under Grant No2014DFH10190the Distinguished Young Scientists Foundation of Jiangsu Province under Grant No BK20130021+1 种基金the National Natural Science Foundation of China under Grant Nos 61204083 and 61306092the Qing Lan Project
文摘The dependencies of hot-carrier-induced degradations on the effective channel length Lch,eff are investigated for n-type metal-oxide-semiconductor field effect transistor (MOSFETs). Our experiments find that, with decreasing Lch,eff, the saturation drain current (Iasat ) degradation is unexpectedly alleviated. The further study demonstrates that the anomalous Lch,eff dependence of Idsat degradation is induced by the increasing influence of the substrate current degradation on the lazar degradation with Lch,eff reducing.
文摘In this paper, based on the results of tomographic image of Tangshan and Xingtai areas, the relations between thecharacteristics of the two strong earthquake sequences and their three-dimensional velocity structures are studied.The research results indicate that:① Mosaic distribution of low-velocity bodies and high-velocity bodies, especially the existence of high-velocity bodies with large size in crust are the common basis of development of thetwo earthquake sequences. ② Scale, depth, and heterogeneity of high-velocity and low-velocity bodies are theimportant factors to effect the characteristic of earthquake sequences. ③ The depth of the high-velocity body inTangshan area is less than that in Xingtai area, which is the principal reason why the dominant focal depth and thebiggest focal depth of Tangshan earthquake sequence are less than Xingtai's. ④ The depth of the high-velocitybodies in Ninghe area is more than that in Tangshan-Luanxian area, which lead to the biggest magnitude and epicentral intensity are lower. These results could be helpful for predicting the main shock of strong swarm-typeearthquakes and later strong aftershocks.
文摘The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).