To improve precision of analytical results of pressurized acid digestion-ICP-MS, the first step is to improve the homogeneity by reducing the particle size of sample. Using of ultra-fine sample (-500 mesh) can reduce ...To improve precision of analytical results of pressurized acid digestion-ICP-MS, the first step is to improve the homogeneity by reducing the particle size of sample. Using of ultra-fine sample (-500 mesh) can reduce the mass of the sample and the acid. The satisfactory precision is achieved at 2 mg sampling mass.展开更多
The material composition of geological samples is very complicated. Generally, the method for accurately determining trace elements in geological samples needs to digest the solid samples into liquid state, which is c...The material composition of geological samples is very complicated. Generally, the method for accurately determining trace elements in geological samples needs to digest the solid samples into liquid state, which is convenient for inductively coupled plasma mass spectrometry. The previous digestion method takes a long time and the operation process is complicated. The Ultra CLAVE microwave digestion instrument was used to digest the geological samples. The types and dosages of the acid used for digestion and the optimal conditions for instrumental testing were published. The results show that this method has short processing time, small data error, safer operation and good digestion effect. This method is suitable for geological sample analysis.展开更多
文摘To improve precision of analytical results of pressurized acid digestion-ICP-MS, the first step is to improve the homogeneity by reducing the particle size of sample. Using of ultra-fine sample (-500 mesh) can reduce the mass of the sample and the acid. The satisfactory precision is achieved at 2 mg sampling mass.
文摘The material composition of geological samples is very complicated. Generally, the method for accurately determining trace elements in geological samples needs to digest the solid samples into liquid state, which is convenient for inductively coupled plasma mass spectrometry. The previous digestion method takes a long time and the operation process is complicated. The Ultra CLAVE microwave digestion instrument was used to digest the geological samples. The types and dosages of the acid used for digestion and the optimal conditions for instrumental testing were published. The results show that this method has short processing time, small data error, safer operation and good digestion effect. This method is suitable for geological sample analysis.