The concentrations of phthalate esters(PAEs) in Chinese hospitals were investigated by simultaneously determining concentrations of gas- and particle-phase PAEs. PAEs were detected in two third-class first-grade hos...The concentrations of phthalate esters(PAEs) in Chinese hospitals were investigated by simultaneously determining concentrations of gas- and particle-phase PAEs. PAEs were detected in two third-class first-grade hospitals, two second-class first-grade hospitals, and a community health service center. Hospital drugstores had the highest concentration(24.19 μg/m3), which was 1.54 times that of newly decorated houses. The second highest concentration was found in the transfusion rooms, averaging 21.89 μg/m3; this was followed by the concentrations of PAEs in the nurse's workstations, the wards, and the doctor's offices, with mean concentrations of 20.66, 20.0, and 16.92 μg/m3, respectively. The lowest concentrations were found in the hallways(16.30 μg/m3). Of the six different kinds of PAEs found, major pollutants included diethyl phthalates, dibutyl phthalates, butylbenzyl phthalates and di(2-ethylhexyl) phthalates, comprising more than 80% of all PAEs present.Meanwhile, a comparison between different wards showed that PAE concentrations in the maternity wards were 1.63 times higher than in the main wards. Based on known health hazards, our results suggest that the PAEs seriously influence the health of the pregnant women and babies; therefore, it is of great importance to take the phthalate concentrations in hospitals into consideration. In addition, hospital indoor air was more seriously contaminated than the air of newly decorated houses.展开更多
To establish the model of indoor air pollution forecast for decoration. Methods The model was based on the balance model for diffusing mass. Results The data between testing concentration and estimating concentration ...To establish the model of indoor air pollution forecast for decoration. Methods The model was based on the balance model for diffusing mass. Results The data between testing concentration and estimating concentration were compared. The maximal error was less than 30% and average error was 14.6%. Conclusion The model can easily predict whether the pollution for decoration exceeds the standard and how long the room is decorated.展开更多
基金supported by a grant from the National Science Foundation of China (No. 20977075)the National High Technology Research and Development Program of China (863) (No. 2010AA064902)
文摘The concentrations of phthalate esters(PAEs) in Chinese hospitals were investigated by simultaneously determining concentrations of gas- and particle-phase PAEs. PAEs were detected in two third-class first-grade hospitals, two second-class first-grade hospitals, and a community health service center. Hospital drugstores had the highest concentration(24.19 μg/m3), which was 1.54 times that of newly decorated houses. The second highest concentration was found in the transfusion rooms, averaging 21.89 μg/m3; this was followed by the concentrations of PAEs in the nurse's workstations, the wards, and the doctor's offices, with mean concentrations of 20.66, 20.0, and 16.92 μg/m3, respectively. The lowest concentrations were found in the hallways(16.30 μg/m3). Of the six different kinds of PAEs found, major pollutants included diethyl phthalates, dibutyl phthalates, butylbenzyl phthalates and di(2-ethylhexyl) phthalates, comprising more than 80% of all PAEs present.Meanwhile, a comparison between different wards showed that PAE concentrations in the maternity wards were 1.63 times higher than in the main wards. Based on known health hazards, our results suggest that the PAEs seriously influence the health of the pregnant women and babies; therefore, it is of great importance to take the phthalate concentrations in hospitals into consideration. In addition, hospital indoor air was more seriously contaminated than the air of newly decorated houses.
基金This study was support by Tenth-five Program of China (2001BA70B02)
文摘To establish the model of indoor air pollution forecast for decoration. Methods The model was based on the balance model for diffusing mass. Results The data between testing concentration and estimating concentration were compared. The maximal error was less than 30% and average error was 14.6%. Conclusion The model can easily predict whether the pollution for decoration exceeds the standard and how long the room is decorated.