In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the...In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the acceleration response waves on the small base isolation system is decreased to about 10%-25% compared to the input waves. Also root mean square amplitude is decreased to about 10%-40%. In case of the ball embedded a cylindrical sponge, the new bearing, the damping ratio increases with increasing width of the cylindrical sponge. The natural frequency does not change. On the other hand, in case of the marble plate that is previous bearing, the damping ratio increases with increasing curvature radius of the marble plate, the natural frequency also increases. Therefore, the small base isolation system using new friction bearing provides better performance. The responses of the base isolation system indicate nonlinier effects by friction force.展开更多
Nonlinear response history analyses and use of strong ground motion data including near-field effects has become a common practice in both performance based design of tall buildings and design of base-isolated buildin...Nonlinear response history analyses and use of strong ground motion data including near-field effects has become a common practice in both performance based design of tall buildings and design of base-isolated buildings. On the other hand, ordinary buildings are commonly analysed via response spectrum analysis following the rules of conventional seismic codes, most of which do not take near-field effects into account. This study evaluates the necessity and the adequacy of near-source factors for ordinary fixed-base buildings that are not specifically classified as tall, by comparing dynamic responses of 3, 8, and 15-story benchmark buildings obtained via (1) linear time history analyses using 220 record components from 13 historical earthquakes and 45 synthetic earthquake records of different magnitudes and fault distances and (2) response spectrum analyses in accordance with the Turkish Earthquake Code 2007 -representing seismic codes not taking near-field effects into account- and the Uniform Building Code 1997 which takes near-field effects into account via near-source factors that amplify design response spectrum. It is shown that near-source factors are crucial for the safe design of not-so-tall ordinary fixed-base buildings but those defined in UBC97 may still not be adequate for those located in the vicinity of the fault.展开更多
文摘In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the acceleration response waves on the small base isolation system is decreased to about 10%-25% compared to the input waves. Also root mean square amplitude is decreased to about 10%-40%. In case of the ball embedded a cylindrical sponge, the new bearing, the damping ratio increases with increasing width of the cylindrical sponge. The natural frequency does not change. On the other hand, in case of the marble plate that is previous bearing, the damping ratio increases with increasing curvature radius of the marble plate, the natural frequency also increases. Therefore, the small base isolation system using new friction bearing provides better performance. The responses of the base isolation system indicate nonlinier effects by friction force.
文摘Nonlinear response history analyses and use of strong ground motion data including near-field effects has become a common practice in both performance based design of tall buildings and design of base-isolated buildings. On the other hand, ordinary buildings are commonly analysed via response spectrum analysis following the rules of conventional seismic codes, most of which do not take near-field effects into account. This study evaluates the necessity and the adequacy of near-source factors for ordinary fixed-base buildings that are not specifically classified as tall, by comparing dynamic responses of 3, 8, and 15-story benchmark buildings obtained via (1) linear time history analyses using 220 record components from 13 historical earthquakes and 45 synthetic earthquake records of different magnitudes and fault distances and (2) response spectrum analyses in accordance with the Turkish Earthquake Code 2007 -representing seismic codes not taking near-field effects into account- and the Uniform Building Code 1997 which takes near-field effects into account via near-source factors that amplify design response spectrum. It is shown that near-source factors are crucial for the safe design of not-so-tall ordinary fixed-base buildings but those defined in UBC97 may still not be adequate for those located in the vicinity of the fault.