Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (O...Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation.In this paper,an OSL dosimeter is described.It has linear dose response from 0.01 to 1000 Gy.The equipment,relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions.展开更多
The space charge accumulation in CdZnTe crystals seriously affects the performance of high-flux pulse detectors.The influence of sub-bandgap illumination on the space charge distribution and device performance in CdZn...The space charge accumulation in CdZnTe crystals seriously affects the performance of high-flux pulse detectors.The influence of sub-bandgap illumination on the space charge distribution and device performance in CdZnTe crystals were studied theoretically by Silvaco TCAD software simulation.The sub-bandgap illumination with a wavelength of 890 nm and intensity of 8×10−8 W/cm2 were used in the simulation to explore the space charge distribution and internal electric field distribution in CdZnTe crystals.The simulation results show that the deep level occupation faction is manipulated by the sub-bandgap illumination,thus space charge concentration can be reduced under the bias voltage of 500 V.A flat electric field distribution is obtained,which significantly improves the charge collection efficiency of the CdZnTe detector.Meanwhile,premised on the high resistivity of CdZnTe crystal,the space charge concentration in the crystal can be further reduced with the wavelength of 850 nm and intensity of 1×10−7 W/cm2 illumination.The electric field distribution is flatter and the carrier collection efficiency of the device can be improved more effectively.展开更多
基金National Natural Science Foundation of China (10475112)Western Light Foundation of 2005 years
文摘Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation.In this paper,an OSL dosimeter is described.It has linear dose response from 0.01 to 1000 Gy.The equipment,relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions.
基金Project supported by the Young Scientists Fund of the National Natural Science Foundation of China(Grant Nos.51702271 and 61904155)the Natural Science Foundation of Fujian Province,China(Grant No.2020J05239).
文摘The space charge accumulation in CdZnTe crystals seriously affects the performance of high-flux pulse detectors.The influence of sub-bandgap illumination on the space charge distribution and device performance in CdZnTe crystals were studied theoretically by Silvaco TCAD software simulation.The sub-bandgap illumination with a wavelength of 890 nm and intensity of 8×10−8 W/cm2 were used in the simulation to explore the space charge distribution and internal electric field distribution in CdZnTe crystals.The simulation results show that the deep level occupation faction is manipulated by the sub-bandgap illumination,thus space charge concentration can be reduced under the bias voltage of 500 V.A flat electric field distribution is obtained,which significantly improves the charge collection efficiency of the CdZnTe detector.Meanwhile,premised on the high resistivity of CdZnTe crystal,the space charge concentration in the crystal can be further reduced with the wavelength of 850 nm and intensity of 1×10−7 W/cm2 illumination.The electric field distribution is flatter and the carrier collection efficiency of the device can be improved more effectively.