To the Editor:In the last decade,neoadjuvant chemotherapy(NAC)has become a well-accepted treatment option for breast cancer,although few detailed description of NAC in China has yet been reported.[1]A previous study f...To the Editor:In the last decade,neoadjuvant chemotherapy(NAC)has become a well-accepted treatment option for breast cancer,although few detailed description of NAC in China has yet been reported.[1]A previous study found that among patients with clinically node-negative(cN0)breast cancer,97.7%(432/442)with breast pathologic complete response(bpCR)had ypN0(absence of metastases in the axillary lymph nodes);and 71.6%(882/1232)without bpCR achieved ypN0(P<0.001).As for human epidermal growth factor receptor 2(HER2)positive or triple-negative breast cancer(TNBC)that achieved bpCR.展开更多
The rejected specimens from the Emergency Department of the Center of Clinical Laboratory from January 1,2022 to January 1,2023 were analyzed to reduce the specimen rejection rates and to improve the quality of inspec...The rejected specimens from the Emergency Department of the Center of Clinical Laboratory from January 1,2022 to January 1,2023 were analyzed to reduce the specimen rejection rates and to improve the quality of inspection.The results showed that there were 1488 samples of rejected specimens and the non-conforming rate was 0.58%.The departments involved were mainly the Emergency Department,the Hematology Department,the Cardiology Department,the Intensive Care Department,and the Brain Surgery Department.Among the reasons for rejection,blood hemolysis accounted for 43.15%,blood coagulation accounted for 26.61%,and the rate of insufficient specimens was 17.14%.Among them,the sample rejection rate for arterial blood gas analysis was the highest,which accounted for 1.74%;followed by specimens for coagulation test,which was 1.18%.These results indicate the main reason for producing rejected specimens is mainly due to not following the standard operating procedure.Specimen rejection can largely be avoided if the standards for specimen collection are strictly followed.展开更多
This paper consolidates the activity of design and fabrication of 2.9 - 4.32 GHz, 4.3 - 6.42 GHz, and 6.4 - 8.4 GHz filter bank. Novel compact microstrip bandpass filters with stub-loaded multi-mode resonators are pro...This paper consolidates the activity of design and fabrication of 2.9 - 4.32 GHz, 4.3 - 6.42 GHz, and 6.4 - 8.4 GHz filter bank. Novel compact microstrip bandpass filters with stub-loaded multi-mode resonators are proposed. Simulated results indicate that all the filters exhibit insertion losses less than 1.5 dB with passband ripples of 1 dB and sharp attenuations of above 40 dB in their stopbands. The maximums of input and output VSWRs are 1.742 and 1.734, respectively. Due to fabrication error, the initial measured passbands show frequency shifts and insertion losses in upper passbands deteriorate seriously. After tuning of the filter bank, measured results imply that the input and output VSWRs are found lower than 2.135 and 2.187, and the insertion loss in 1 dB bandwidth is less than 2.52 dB. Filter bank has a sharp skirt and out-of-band rejection levels approaching to 40 dB in all desired stopbands except at the frequencies near 2f0.展开更多
基金Beijing Medical Reward Foundation(No.YXJL-2016-0040-0012)
文摘To the Editor:In the last decade,neoadjuvant chemotherapy(NAC)has become a well-accepted treatment option for breast cancer,although few detailed description of NAC in China has yet been reported.[1]A previous study found that among patients with clinically node-negative(cN0)breast cancer,97.7%(432/442)with breast pathologic complete response(bpCR)had ypN0(absence of metastases in the axillary lymph nodes);and 71.6%(882/1232)without bpCR achieved ypN0(P<0.001).As for human epidermal growth factor receptor 2(HER2)positive or triple-negative breast cancer(TNBC)that achieved bpCR.
文摘The rejected specimens from the Emergency Department of the Center of Clinical Laboratory from January 1,2022 to January 1,2023 were analyzed to reduce the specimen rejection rates and to improve the quality of inspection.The results showed that there were 1488 samples of rejected specimens and the non-conforming rate was 0.58%.The departments involved were mainly the Emergency Department,the Hematology Department,the Cardiology Department,the Intensive Care Department,and the Brain Surgery Department.Among the reasons for rejection,blood hemolysis accounted for 43.15%,blood coagulation accounted for 26.61%,and the rate of insufficient specimens was 17.14%.Among them,the sample rejection rate for arterial blood gas analysis was the highest,which accounted for 1.74%;followed by specimens for coagulation test,which was 1.18%.These results indicate the main reason for producing rejected specimens is mainly due to not following the standard operating procedure.Specimen rejection can largely be avoided if the standards for specimen collection are strictly followed.
文摘This paper consolidates the activity of design and fabrication of 2.9 - 4.32 GHz, 4.3 - 6.42 GHz, and 6.4 - 8.4 GHz filter bank. Novel compact microstrip bandpass filters with stub-loaded multi-mode resonators are proposed. Simulated results indicate that all the filters exhibit insertion losses less than 1.5 dB with passband ripples of 1 dB and sharp attenuations of above 40 dB in their stopbands. The maximums of input and output VSWRs are 1.742 and 1.734, respectively. Due to fabrication error, the initial measured passbands show frequency shifts and insertion losses in upper passbands deteriorate seriously. After tuning of the filter bank, measured results imply that the input and output VSWRs are found lower than 2.135 and 2.187, and the insertion loss in 1 dB bandwidth is less than 2.52 dB. Filter bank has a sharp skirt and out-of-band rejection levels approaching to 40 dB in all desired stopbands except at the frequencies near 2f0.