A new multi-channel motional Stark effect(MSE)diagnostic system has been developed on the upgraded EAST tokamak,which was installed on the port C to observe a tangential neutral beam.A telecentric imaging lens was dep...A new multi-channel motional Stark effect(MSE)diagnostic system has been developed on the upgraded EAST tokamak,which was installed on the port C to observe a tangential neutral beam.A telecentric imaging lens was deployed to ensure uniform illumination from the core to the boundary.A square fiber head which contained 23 fiber bundles was mounted to this imaging lens;each fiber bundle contained 19 fibers and two of them were assigned to CXRS and BES spectrometer,respectively.The angle tuning method was used for matching the Doppler shift of theσcomponent’s wavelength which was caused by the beam voltage.At the present stage,the MSE system only contains ten channels that would be extended to 23 channels in the future,covering a measurement range from R=1.8 to R=2.27 m with a temporal resolution of 10 ms and a spatial resolution of3 cm.The polarization angle-constrained q profiles and current density profiles were reconstructed with EFIT equilibrium reconstructions.In the sawtooth discharges,the q=1 surface position was validated by the ECE signals,which further verified the rationality of the MSE measurement.展开更多
基金supported by the National MCF Energy R&D Program of China(No.2019YFE03040000)National Natural Science Foundation of China(Nos.12075280 and 11805236)+2 种基金Anhui Provincial Natural Science Foundation(No.1908085J01)CAS President’s International Fellowship Initiative(No.2022VMB0007)Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-73-01-001228)。
文摘A new multi-channel motional Stark effect(MSE)diagnostic system has been developed on the upgraded EAST tokamak,which was installed on the port C to observe a tangential neutral beam.A telecentric imaging lens was deployed to ensure uniform illumination from the core to the boundary.A square fiber head which contained 23 fiber bundles was mounted to this imaging lens;each fiber bundle contained 19 fibers and two of them were assigned to CXRS and BES spectrometer,respectively.The angle tuning method was used for matching the Doppler shift of theσcomponent’s wavelength which was caused by the beam voltage.At the present stage,the MSE system only contains ten channels that would be extended to 23 channels in the future,covering a measurement range from R=1.8 to R=2.27 m with a temporal resolution of 10 ms and a spatial resolution of3 cm.The polarization angle-constrained q profiles and current density profiles were reconstructed with EFIT equilibrium reconstructions.In the sawtooth discharges,the q=1 surface position was validated by the ECE signals,which further verified the rationality of the MSE measurement.