期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A combined magnetic field stabilization system for improving the stability of 40Ca^(+) optical clock
1
作者 曾孟彦 马子晓 +6 位作者 胡如明 张宝林 郝艳梅 张华青 黄垚 管桦 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期226-231,共6页
Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise supp... Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise suppression system. On the one hand, we have optimized the magnetic shielding performance of the portable optical clock by reducing its apertures and optimizing its geometry;on the other hand, we have introduced an active magnetic field noise suppression system to further suppress the magnetic field noise experienced by the ions. These efforts reduced the ambient magnetic field noise by about 10000 times, significantly reduced the linewidth of the clock transition spectrum, improved the stability of the portable40Ca+optical clock, and created the conditions for using portable optical clocks in non-laboratory magnetic field environments. This active magnetic field suppression scheme has the advantages of simple installation and wide applicability. 展开更多
关键词 40Ca^(+)optical clock magnetic field compensation frequency stability
下载PDF
A cryogenic radio-frequency ion trap for a 40Ca^(+) optical clock
2
作者 曾孟彦 黄垚 +6 位作者 张宝林 马子晓 郝艳梅 胡如明 张华青 管桦 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期232-239,共8页
A liquid-nitrogen cryogenic40Ca^(+)optical clock is presented that is designed to greatly reduce the blackbody radiation(BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the li... A liquid-nitrogen cryogenic40Ca^(+)optical clock is presented that is designed to greatly reduce the blackbody radiation(BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the liquid-nitrogen container,keeping the ions in a cryogenic environment at liquid-nitrogen temperature. Compared with the first design in our previous work, many improvements have been made to increase the performance. The liquid-nitrogen maintenance time has been increased by about three times by increasing the volume of the liquid-nitrogen container;the trap position recovery time after refilling the liquid-nitrogen container has been decreased more than three times by using a better fixation scheme in the liquid-nitrogen container;and the magnetic field noise felt by the ions has been decreased more than three times by a better design of the magnetic shielding system. These optimizations make the scheme for reducing the BBR shift uncertainty of liquid-nitrogen-cooled optical clocks more mature and stable, and develop a stable lock with a narrower linewidth spectrum,which would be very beneficial for further reducing the overall systematic uncertainty of optical clocks. 展开更多
关键词 cryogenics ion trapping 40Ca^(+)optical clock
下载PDF
胎盘植入严重不良妊娠结局相关危险因素分析 被引量:16
3
作者 李秀英 李晓梅 +8 位作者 潘燕梅 颜昊 王鑫 匡丽云 汤雯婷 龚景进 王春燕 池晓东 陈敦金 《中国妇产科临床杂志》 CSCD 北大核心 2016年第6期519-522,共4页
目的探讨胎盘植入孕产妇发生严重不良妊娠结局的相关危险因素。方法回顾性分析广州医科大学附属第三医院2009年1月至2015年6月651例胎盘植入患者的临床资料。结果胎盘植入孕产妇严重不良妊娠结局的发生率为39.6%(258/651)。单因素分... 目的探讨胎盘植入孕产妇发生严重不良妊娠结局的相关危险因素。方法回顾性分析广州医科大学附属第三医院2009年1月至2015年6月651例胎盘植入患者的临床资料。结果胎盘植入孕产妇严重不良妊娠结局的发生率为39.6%(258/651)。单因素分析显示,年龄、孕次、产次、流产次数、剖宫产次数、产前阴道出血次数、终止妊娠孕周、胎盘植入类型、未规律产前检查、合并内科疾病和合并前置胎盘是胎盘植入孕产妇发生严重不良妊娠结局的相关危险因素(P〈0.05);多因素logistic回归分析显示,剖宫产次数(OR=2.248,95%CI:1.590~3.177,P=0.000)、合并内科疾病(OR=1.604,95%CI:1.080~2.384,P=0.019)和合并前置胎盘(OR=1.877,95%CI:1.204~2.925,P=0.005)是胎盘植入孕产妇发生严重不良妊娠结局的独立危险因素。结论胎盘植入孕产妇发生严重不良妊娠结局的独立危险因素为剖宫产次数、合并内科疾病及前置胎盘。 展开更多
关键词 胎盘植入 严重不良妊娠结局 危险因素
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部