Loop heat pipes(LHPs),as high-efficiency heat dissipation components,are considered to be superior thermal conductors beyond any known materials.To apply LHPs to mobile electronics,a small,thin and compact system need...Loop heat pipes(LHPs),as high-efficiency heat dissipation components,are considered to be superior thermal conductors beyond any known materials.To apply LHPs to mobile electronics,a small,thin and compact system needs to be designed.However,with the trend of miniaturization,the heat transfer performance of LHPs degrades rapidly due to the significant increase of working fluid backflow resistance.This work aims to propose an effective solution to this problem.In this work,the surface wettability gradient(SWG)is introduced into the ultra-thin LHP,and the influence of SWG on mass and heat transfer performance is studied comprehensively by using a transient three-dimensional numerical model.It is observed that the SWG can significantly increase the vapor-liquid circulation efficiency and improve heat transfer performance.Numerical experiments have been performed to compare the two kinds of LHPs with and without SWG.At the heat load of 4–6 W,the start-up time for LHP with SWG is shortened by 11.5%and the thermal resistance is reduced by about 44.3%,compared with the LHP without SWG.This work provides a solution for the performance-degradation problem caused by miniaturization,as a numerical reference for experiments.展开更多
[Objective] The study aimed to discuss the effects of coal mining subsided water area on temperature change in Huaibei coal mine. [Method] Based on the data of monthly temperature from 1957 to 2007 recorded by Suixi ...[Objective] The study aimed to discuss the effects of coal mining subsided water area on temperature change in Huaibei coal mine. [Method] Based on the data of monthly temperature from 1957 to 2007 recorded by Suixi (coal mining subsided water area) and Fuyang stations (control), the effects of coal mining subsided water area on temperature change in Huaibei coal mine were discussed using linear trend estimation and comparative analysis methods. [Result] Spring, autumn, winter and annual average temperatures of coal mining subsided water area (Suixi) were increased in the last 51 years, and the increase of winter temperature was mostly significant with a tendency rate of 0.49 ℃/10 a. Meanwhile, annual temperature range of coal mining subsided water area was decreased from 1957 to 2007. Temperatures of Suixi in four seasons were lower than those of Fuyang from the 1960s to 1990s, and temperatures of coal mining subsided water area (Suixi) were higher than those of Fuyang in spring, autumn and winter but lower than those of Fuyang in summer from 2000 to 2007. [ Result] Coal mining subsided water area had certain effects on temperature change of Huaibei coal mine.展开更多
基金financial supports from the Science and Technology Innovation Commission of Shenzhen(Grant No.JCYJ20190809154007586)National Key Research and Development Program of China(Grant No.2017YFE0120800)+1 种基金National Natural Science Foundation of China(Grant No.U20A20241 and No.51702277)Science and Technology Development Fund of the Macao Special Administrative Region(Grant No.FDCT/013/2017/AMJ)。
文摘Loop heat pipes(LHPs),as high-efficiency heat dissipation components,are considered to be superior thermal conductors beyond any known materials.To apply LHPs to mobile electronics,a small,thin and compact system needs to be designed.However,with the trend of miniaturization,the heat transfer performance of LHPs degrades rapidly due to the significant increase of working fluid backflow resistance.This work aims to propose an effective solution to this problem.In this work,the surface wettability gradient(SWG)is introduced into the ultra-thin LHP,and the influence of SWG on mass and heat transfer performance is studied comprehensively by using a transient three-dimensional numerical model.It is observed that the SWG can significantly increase the vapor-liquid circulation efficiency and improve heat transfer performance.Numerical experiments have been performed to compare the two kinds of LHPs with and without SWG.At the heat load of 4–6 W,the start-up time for LHP with SWG is shortened by 11.5%and the thermal resistance is reduced by about 44.3%,compared with the LHP without SWG.This work provides a solution for the performance-degradation problem caused by miniaturization,as a numerical reference for experiments.
基金Supported by the Key Project of Provincial Natural Science Research for Colleges and Universities in Anhui Province, China ( KJ2013A244)
文摘[Objective] The study aimed to discuss the effects of coal mining subsided water area on temperature change in Huaibei coal mine. [Method] Based on the data of monthly temperature from 1957 to 2007 recorded by Suixi (coal mining subsided water area) and Fuyang stations (control), the effects of coal mining subsided water area on temperature change in Huaibei coal mine were discussed using linear trend estimation and comparative analysis methods. [Result] Spring, autumn, winter and annual average temperatures of coal mining subsided water area (Suixi) were increased in the last 51 years, and the increase of winter temperature was mostly significant with a tendency rate of 0.49 ℃/10 a. Meanwhile, annual temperature range of coal mining subsided water area was decreased from 1957 to 2007. Temperatures of Suixi in four seasons were lower than those of Fuyang from the 1960s to 1990s, and temperatures of coal mining subsided water area (Suixi) were higher than those of Fuyang in spring, autumn and winter but lower than those of Fuyang in summer from 2000 to 2007. [ Result] Coal mining subsided water area had certain effects on temperature change of Huaibei coal mine.