Research on a single cell Multi-gap Resistive Plate Chamber (MRPC) was carried out for the Time Of Flight detector (TOF) R and D of the STAR experi- ment. The property of the single chamber was tested with the test be...Research on a single cell Multi-gap Resistive Plate Chamber (MRPC) was carried out for the Time Of Flight detector (TOF) R and D of the STAR experi- ment. The property of the single chamber was tested with the test beam facility T10 at CERN in Geneva. The MRPC was scanned with the test beam to get the efficiency and time resolution at different position of the active area. The HV plateau was also measured. The time resolution is 65 ps which satisfies the requirement of STAR. The working mechanism of the MRPC is also explained.展开更多
A high dynamic range readout system,consisting of a multi-dynode readout PMT and a VA32 chip,is presented.An LED system is set up to calibrate the relative gains between the dynodes,and the ADC counts per MIPs from dy...A high dynamic range readout system,consisting of a multi-dynode readout PMT and a VA32 chip,is presented.An LED system is set up to calibrate the relative gains between the dynodes,and the ADC counts per MIPs from dynode 7 are determined under cosmic-ray calibration.A dynamic range from 0.5 MIPs to 1×10 5 MIPs is achieved.展开更多
Due to the current trend towards lightweight design in automotive industry,hollow stepped gear shafts for automobile and its radial forging process are widely investigated.Utilizing coupled finite element thermo-mecha...Due to the current trend towards lightweight design in automotive industry,hollow stepped gear shafts for automobile and its radial forging process are widely investigated.Utilizing coupled finite element thermo-mechanical model,radial forging process of a hollow stepped gear shaft for automobile was simulated.The optimal combination of three process parameters including initial temperature,rotation rate and radial reduction was also selected using orthogonal design method.To examine the strain inhomogeneity of the forging workpiece,the strain inhomogeneity factor was introduced.The results reveal that the maximum effective strain and the minimum effective strain appeared in the outermost and innermost zones of different cross sections for the hollow stepped gear shaft,respectively.Optimal forging parameters are determined as a combination of initial temperature of 780°C,rotation rate of 21°/stroke and radial reduction of 3 mm.展开更多
A set of point spread functions (PSF) has been obtained by means of Monte-Carlo simulation for asmall gamma camera with a pinhole collimator of various hole diameters. The FOV (field of view) of the camera isexpended ...A set of point spread functions (PSF) has been obtained by means of Monte-Carlo simulation for asmall gamma camera with a pinhole collimator of various hole diameters. The FOV (field of view) of the camera isexpended from 45 mm to 70 mm in diameter. The position dependence of the variances of PSF is presented, and theacceptance for the 140 kev gamma rays is explored. A phantom of 70 mm in diameter was experimentally imaged inthe camera with effective FOV of only 45 mm in diameter.展开更多
The performance of gamma camera with NaI(Tl) array coupled with position sensitive photomultiplier tube (PSPMT) R2486 has been studied. The pixel size of NaI(Tl) crystal is 2mm×2mm and the overall dimension of th...The performance of gamma camera with NaI(Tl) array coupled with position sensitive photomultiplier tube (PSPMT) R2486 has been studied. The pixel size of NaI(Tl) crystal is 2mm×2mm and the overall dimension of the array is 48.2mm×48.2mm×5mm. There are 484 pixels in a 22×22 matrix. Because each pixel can produce a much focused light spot and restrict the spread of photons, position resolution of the gamma camera is mainly determined by pixel size. It is shown that crystal array pixel can reduce shrinkage effect and improve intrinsic position resolution greatly via restricting the spread of photons. Experimental results demonstrate that its position resolution and linearity are much improved comparing with the gamma camera using planar crystals coupled with PSPMT.展开更多
Emission spectra,longitudinal transmission and light output for the Sb-doped and Y-doped PbWO_(4) crystals are presented.Scintillation decay kinetics has been measured by using gate integration and single photon count...Emission spectra,longitudinal transmission and light output for the Sb-doped and Y-doped PbWO_(4) crystals are presented.Scintillation decay kinetics has been measured by using gate integration and single photon counting method with blue and green filters.Radiation hardness has also been measured by using ^(60)Coγ-ray irradiation under different dose rates and different dose rate profiles.The light yield and radiation hardness of the Sb-doped and Y-doped PbWO_(4) crystals are improved as compared to the undoped crystals and are suitable for the requirements of compact muon solenoid.展开更多
The aging test of multigap resistive chamber (MRPC) was carried out under conditions of irradiation from a 137Cs γ source facility. The total charge induced at the anode or at the cathode of the MRPC module was about...The aging test of multigap resistive chamber (MRPC) was carried out under conditions of irradiation from a 137Cs γ source facility. The total charge induced at the anode or at the cathode of the MRPC module was about 29 mC. The gamma dose rate was 10-2 Gy·h-1, and the total accumulative radiation dose was 4.3 Gy. After irradiation, there was an obvious degradation in the properties of the MRPC module.展开更多
文摘Research on a single cell Multi-gap Resistive Plate Chamber (MRPC) was carried out for the Time Of Flight detector (TOF) R and D of the STAR experi- ment. The property of the single chamber was tested with the test beam facility T10 at CERN in Geneva. The MRPC was scanned with the test beam to get the efficiency and time resolution at different position of the active area. The HV plateau was also measured. The time resolution is 65 ps which satisfies the requirement of STAR. The working mechanism of the MRPC is also explained.
基金Supported by Ministry of Science and Technology of China (2010CB833002)Innovative Program of Chinese Academy of Sciences (KJCX2-YW-T16)
文摘A high dynamic range readout system,consisting of a multi-dynode readout PMT and a VA32 chip,is presented.An LED system is set up to calibrate the relative gains between the dynodes,and the ADC counts per MIPs from dynode 7 are determined under cosmic-ray calibration.A dynamic range from 0.5 MIPs to 1×10 5 MIPs is achieved.
基金Projects(51774054,51974050)supported by the National Natural Science Foundation of China。
文摘Due to the current trend towards lightweight design in automotive industry,hollow stepped gear shafts for automobile and its radial forging process are widely investigated.Utilizing coupled finite element thermo-mechanical model,radial forging process of a hollow stepped gear shaft for automobile was simulated.The optimal combination of three process parameters including initial temperature,rotation rate and radial reduction was also selected using orthogonal design method.To examine the strain inhomogeneity of the forging workpiece,the strain inhomogeneity factor was introduced.The results reveal that the maximum effective strain and the minimum effective strain appeared in the outermost and innermost zones of different cross sections for the hollow stepped gear shaft,respectively.Optimal forging parameters are determined as a combination of initial temperature of 780°C,rotation rate of 21°/stroke and radial reduction of 3 mm.
基金Supported by the National Natural Science Foundation of China(10275063)
文摘A set of point spread functions (PSF) has been obtained by means of Monte-Carlo simulation for asmall gamma camera with a pinhole collimator of various hole diameters. The FOV (field of view) of the camera isexpended from 45 mm to 70 mm in diameter. The position dependence of the variances of PSF is presented, and theacceptance for the 140 kev gamma rays is explored. A phantom of 70 mm in diameter was experimentally imaged inthe camera with effective FOV of only 45 mm in diameter.
基金Supported by National Foundation of Natural Sciences of China (10275063)
文摘The performance of gamma camera with NaI(Tl) array coupled with position sensitive photomultiplier tube (PSPMT) R2486 has been studied. The pixel size of NaI(Tl) crystal is 2mm×2mm and the overall dimension of the array is 48.2mm×48.2mm×5mm. There are 484 pixels in a 22×22 matrix. Because each pixel can produce a much focused light spot and restrict the spread of photons, position resolution of the gamma camera is mainly determined by pixel size. It is shown that crystal array pixel can reduce shrinkage effect and improve intrinsic position resolution greatly via restricting the spread of photons. Experimental results demonstrate that its position resolution and linearity are much improved comparing with the gamma camera using planar crystals coupled with PSPMT.
基金Supported by the National Natural Science Foundation of China under Grant No.59932002.
文摘Emission spectra,longitudinal transmission and light output for the Sb-doped and Y-doped PbWO_(4) crystals are presented.Scintillation decay kinetics has been measured by using gate integration and single photon counting method with blue and green filters.Radiation hardness has also been measured by using ^(60)Coγ-ray irradiation under different dose rates and different dose rate profiles.The light yield and radiation hardness of the Sb-doped and Y-doped PbWO_(4) crystals are improved as compared to the undoped crystals and are suitable for the requirements of compact muon solenoid.
基金Supported by National Natural Science Foundation of China (10475074)
文摘The aging test of multigap resistive chamber (MRPC) was carried out under conditions of irradiation from a 137Cs γ source facility. The total charge induced at the anode or at the cathode of the MRPC module was about 29 mC. The gamma dose rate was 10-2 Gy·h-1, and the total accumulative radiation dose was 4.3 Gy. After irradiation, there was an obvious degradation in the properties of the MRPC module.