To evaluate the relationship between measures of body composition in obese adolescents by the methods of bioelectrical impedance analysis, deuterium oxide dilution and anthropometric measures, proposing an equation. T...To evaluate the relationship between measures of body composition in obese adolescents by the methods of bioelectrical impedance analysis, deuterium oxide dilution and anthropometric measures, proposing an equation. The variables were weight, height, BMI, triceps and subscapular skinfold thickness, waist and arm muscle circumference, lean body mass, fat mass and total body water by bioelectrical impedance and deuterium oxide dilution methods. The study included 40 obese adolescents, 45% male, age distribution was 2.42 ± 1.19 years and females 55%, and the predominant age was 12.61 ± 1.78. Linear regression equations were developed, capable of predicting body composition from information supplied by the method of deuterium oxide dilution (gold standard), bioelectrical impedance and anthropometry. The variables gender, age, height, arm circumference, triceps and suprailiac skin fold thickness, resistance and reactance were used to estimate lean body mass, fat mass and total body water by the method of deuterium and significantly correlated with variables, resistance, reactance, sex and total body water (TBW) by bioimpedance method. Among the equations developed, five were suitable for this sample, therefore, it is suggested that more studies should be done to test the applicability of the equations in other samples so that we can validate the equations encountered in obese adolescents.展开更多
Polysaccharide-based composite materials(beads) containing silver nanoparticles(AgNPs) were successfully prepared.Hydrogel beads acted as an efficient vehicle for Ag* delivery.Beads promoted the AgNPs protection ...Polysaccharide-based composite materials(beads) containing silver nanoparticles(AgNPs) were successfully prepared.Hydrogel beads acted as an efficient vehicle for Ag* delivery.Beads promoted the AgNPs protection and inhibited their aggregation.Antimicrobial assays showed that the beads/AgNPs concentration can be modulated to deliver an amount of Ag* necessary for kill Escherichia coli cells.展开更多
The respective compounds of copper, cadmium and lead, owing to their strong toxic potential, as a result of industrial effluent, have left a trail of contamination in humans and the environment. This paper aimed to st...The respective compounds of copper, cadmium and lead, owing to their strong toxic potential, as a result of industrial effluent, have left a trail of contamination in humans and the environment. This paper aimed to study the electrode position on the removal of aqueous solutions of cadmium, lead and copper, using an electrolytic cell with a metallic screen cathode of carbon steel and platinum anode. Removal efficiencies were obtained by analysis of the solutions before and after treatment, using the methodology of cathodic-stripping voltammetry with a mercury drop electrode to quantify the concentrations of Cd<sup>2+</sup>, Pb2<sup>2+</sup> and Cu<sup>2+</sup>. Removal efficiencies were obtained of 94.07% for cadmium, 94.71% for lead and 96.19% for copper, demonstrating that electrolytic removal is an effective technique for the removal of these metals from simulated industrial wastewater.展开更多
Industrial effluents containing cobalt ions have become a serious problem for the environment, unless properly treated, due to their toxic potential. Currently there has been an intensification of the use of cobalt in...Industrial effluents containing cobalt ions have become a serious problem for the environment, unless properly treated, due to their toxic potential. Currently there has been an intensification of the use of cobalt in several industrial sectors as super alloys, catalysts, batteries and pigments in ceramic materials, and a consequent intensification also of environmental contamination. This paper aims to show a simple and effective treatment for the removal of cobalt ions from simulated industrial wastewater, based on cathodic eletrolytic removal using a carbon steel screen. As a result, a 73% removal of cobalt ions from solutions was achieved with a concentration of 400 mg Co<sup>2+</sup>/L, a current of 0.30 A and a voltage of 30 V. In the same conditions, 84% and 88% was removed from 200 mg Co<sup>2+</sup>/L and 100 mg Co<sup>2+</sup>/L, respectively. Thus, this method presents itself as a cheap and efficient alternative for the treatment of industrial effluents containing cobalt ions.展开更多
文摘To evaluate the relationship between measures of body composition in obese adolescents by the methods of bioelectrical impedance analysis, deuterium oxide dilution and anthropometric measures, proposing an equation. The variables were weight, height, BMI, triceps and subscapular skinfold thickness, waist and arm muscle circumference, lean body mass, fat mass and total body water by bioelectrical impedance and deuterium oxide dilution methods. The study included 40 obese adolescents, 45% male, age distribution was 2.42 ± 1.19 years and females 55%, and the predominant age was 12.61 ± 1.78. Linear regression equations were developed, capable of predicting body composition from information supplied by the method of deuterium oxide dilution (gold standard), bioelectrical impedance and anthropometry. The variables gender, age, height, arm circumference, triceps and suprailiac skin fold thickness, resistance and reactance were used to estimate lean body mass, fat mass and total body water by the method of deuterium and significantly correlated with variables, resistance, reactance, sex and total body water (TBW) by bioimpedance method. Among the equations developed, five were suitable for this sample, therefore, it is suggested that more studies should be done to test the applicability of the equations in other samples so that we can validate the equations encountered in obese adolescents.
基金the financial support (Nos.481424/2010-5 and 308337/2013-1)
文摘Polysaccharide-based composite materials(beads) containing silver nanoparticles(AgNPs) were successfully prepared.Hydrogel beads acted as an efficient vehicle for Ag* delivery.Beads promoted the AgNPs protection and inhibited their aggregation.Antimicrobial assays showed that the beads/AgNPs concentration can be modulated to deliver an amount of Ag* necessary for kill Escherichia coli cells.
文摘The respective compounds of copper, cadmium and lead, owing to their strong toxic potential, as a result of industrial effluent, have left a trail of contamination in humans and the environment. This paper aimed to study the electrode position on the removal of aqueous solutions of cadmium, lead and copper, using an electrolytic cell with a metallic screen cathode of carbon steel and platinum anode. Removal efficiencies were obtained by analysis of the solutions before and after treatment, using the methodology of cathodic-stripping voltammetry with a mercury drop electrode to quantify the concentrations of Cd<sup>2+</sup>, Pb2<sup>2+</sup> and Cu<sup>2+</sup>. Removal efficiencies were obtained of 94.07% for cadmium, 94.71% for lead and 96.19% for copper, demonstrating that electrolytic removal is an effective technique for the removal of these metals from simulated industrial wastewater.
文摘Industrial effluents containing cobalt ions have become a serious problem for the environment, unless properly treated, due to their toxic potential. Currently there has been an intensification of the use of cobalt in several industrial sectors as super alloys, catalysts, batteries and pigments in ceramic materials, and a consequent intensification also of environmental contamination. This paper aims to show a simple and effective treatment for the removal of cobalt ions from simulated industrial wastewater, based on cathodic eletrolytic removal using a carbon steel screen. As a result, a 73% removal of cobalt ions from solutions was achieved with a concentration of 400 mg Co<sup>2+</sup>/L, a current of 0.30 A and a voltage of 30 V. In the same conditions, 84% and 88% was removed from 200 mg Co<sup>2+</sup>/L and 100 mg Co<sup>2+</sup>/L, respectively. Thus, this method presents itself as a cheap and efficient alternative for the treatment of industrial effluents containing cobalt ions.