期刊文献+
共找到46篇文章
< 1 2 3 >
每页显示 20 50 100
冠状动脉内影像学临床应用专家共识(第一部分):对冠状动脉介入治疗的指导与优化 被引量:19
1
作者 Lorenz Raber Gary S mintz +19 位作者 Konstantinos C Koskinas Thomas W Johnson Niels R Holm Yoshinubo Onuma Maria D Radu Michael Joner Bo Yu Haibo Jia Nicolas Meneveau Jose M.de la Torre Hemandez Javier Escaned Jonathan Hill Francesco Prati Antonio Colombo Carlo di Mario Evelyn Regar Davide Capodanno William Wijns Robert A Byme Giulio Guagliumi 《中华心血管病杂志》 CAS CSCD 北大核心 2019年第1期5-25,共21页
欧洲心血管介入协会(EAPCI)专家组系统总结了血管内超声(IVUS)和光学相干断层成像(OCT)这两种血管内影像学检查临床应用指征的现有证据,提供了关于IVUS和OCT指导经皮冠状动脉介入治疗(PCI)的应用价值,并明确了最可能从腔内影像学指导的... 欧洲心血管介入协会(EAPCI)专家组系统总结了血管内超声(IVUS)和光学相干断层成像(OCT)这两种血管内影像学检查临床应用指征的现有证据,提供了关于IVUS和OCT指导经皮冠状动脉介入治疗(PCI)的应用价值,并明确了最可能从腔内影像学指导的介入治疗中获得临床收益的患者或病变类型,同时详细论述了PCI前如何使用IVUS或OCT优化支架尺寸(支架长度和直径)和手术策略的选择。此外,专家推荐对支架失败(支架内再狭窄或支架内血栓形成)的患者应常规进行冠状动脉内影像学检查,并首选OCT。最后,重点论述了IVUS和OCT在指导PCI和评估支架失败两个方面的优势和局限性,并对未来需要深入研究的领域进行了展望。 展开更多
关键词 冠状动脉疾病 超声检查 介入性 体层摄影术 光学相干 经皮冠状动脉介入 治疗
原文传递
First report of a novel abluminal groove filled biodegradable polymer rapamycin-eluting stent in de novo coronary artery disease: results of the first in man FIREHAWK trial 被引量:14
2
作者 QIAN Jie XU Bo +9 位作者 Alexandra J. Lansky YANG Yue-jin QIAO Shu-bin WU Yong-jian CHEN Jue HU Feng-huan YANG Wei-xian Gary S. mintz Martin B. Leon GAO Run-lin 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第6期970-976,共7页
Background Durable polymers used for first-generation drug-eluting stents (DES) potentially contribute to persistent inflammation and late DES thrombosis. We report the first in human experience with the rapamycin-e... Background Durable polymers used for first-generation drug-eluting stents (DES) potentially contribute to persistent inflammation and late DES thrombosis. We report the first in human experience with the rapamycin-eluting biodegradable polymer coated cobalt-chromium FIREHAWK stent with abluminal groove. Methods A total of 21 patients with stable or unstable angina, or prior myocardial infarction, with single de novo native coronary stenoses 〈30 mm in length in vessel sizes ranging from 2.25 to 4.0 mm were enrolled. The primary endpoint was major adverse cardiac events (MACE) at 30 days defined as the composite of cardiac death, myocardial infarction (Q and non-Q), or ischemia-driven target lesion revascularization. Secondary endpoints include device, lesion, and clinical success rates, 4-month in-stent late lumen loss by quantitative coronary angiography (QCA), proportion of uncovered or malapposed stent struts by optical coherence tomograpphy (OCT) at 4 months, and MACE at 4, 12, 24 and 36-month follow-up. Results Device success was 95.7%, lesion and clinical success was 100.0%. There were no MACE events at 30 days. One patient died of non-cardiac hemorrhagic stroke 5 days after index procedure. At 4 months, in-stent late loss was (0.13±0.18) mm, and complete strut coverage was 96.2% by OCT with 0.1% strut malapposition. At 4-month follow-up there was no additional MACE events, and a single target vessel (non-target lesion) revascularization. Conclusions The FIREHAWK abluminal groove biodegradable polymer rapamycin-eluting stent demonstrated feasibility, safety and efficacy in this first in human experience. OCT findings indicated excellent stent strut coverage 4 months after implantation. Larger studies are required to confirm whether the early FIREHAWK stent results translate into longer term restenosis and thrombosis benefits. 展开更多
关键词 rapamycin-eluting stent first-in-man study optical coherence tomography coronary artery disease
原文传递
Evaluation of hand infections in the emergency department using point-of-care ultrasound 被引量:1
3
作者 David Ahmad Haidar David mintz +2 位作者 Brandon M Wubben Omar Rizvi Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期283-288,共6页
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana... BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care. 展开更多
关键词 ULTRASOUND Point-of-care ultrasound CELLULITIS ABSCESS Flexor tenosynovitis
下载PDF
The role of natural killer cells in the uterine microenvironment during pregnancy 被引量:4
4
作者 Julia P.Andreotti Ana E.Paiva +5 位作者 Pedro H.D.M.Prazeres Daniel A.P.Guerra Walison N.Silva Rogerio S.Vaz Akiva mintz Alexander Birbrair 《Cellular & Molecular Immunology》 SCIE CAS CSCD 2018年第11期941-943,共3页
Pregnancy is a choreographed physiological phenomenon that involves maternal-fetal cross-talk.Elucidating the cellular and molecular mechanisms involved in this communication will allow us to develop therapies for ges... Pregnancy is a choreographed physiological phenomenon that involves maternal-fetal cross-talk.Elucidating the cellular and molecular mechanisms involved in this communication will allow us to develop therapies for gestational complications.Little is known about the role of natural killer(NK)cells in the uterine microenvironment.In a recent study,Fu et al.(2017)used state-of-art technologies and showed that NK cells stimulate fetal growth via growth-promoting factors. 展开更多
关键词 KILLER FETAL UTERINE
原文传递
Pericyte Plasticity in the Brain 被引量:4
5
作者 Gabryella S.P.Santos Luiz A.V.Magno +2 位作者 Marco A.Romano-Silva Akiva mintz Alexander Birbrair 《Neuroscience Bulletin》 SCIE CAS CSCD 2019年第3期551-560,共10页
Cerebral pericytes are perivascular cells that stabilize blood vessels. Little is known about the plasticity of pericytes in the adult brain in vivo. Recently, using stateof-the-art technologies, including two-photon ... Cerebral pericytes are perivascular cells that stabilize blood vessels. Little is known about the plasticity of pericytes in the adult brain in vivo. Recently, using stateof-the-art technologies, including two-photon microscopy in combination with sophisticated Cre/loxP in vivo tracing techniques, a novel role of pericytes was revealed in vascular remodeling in the adult brain. Strikingly, after pericyte ablation, neighboring pericytes expand their processes and prevent vascular dilatation. This new knowledge provides insights into pericyte plasticity in the adult brain. 展开更多
关键词 PERICYTES BRAIN Blood vessel PLASTICITY
原文传递
Clinical outcome after management of unprotected left main in-stent restenosis after bare metal or drug-eluting stents 被引量:3
6
作者 CHEN Shao-liang XU Bo +8 位作者 Gary mintz YE Fei ZHANG Jun-jie KAN Jing SUN Xue-wen ZHANG Ai-ping CHEN Jin-guo QIAN Jun Kwan Tak W 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第7期794-799,共6页
Background Implantation of either bare metal stent (BMS) or drug-eluting stent (DES) has been used in every day practice for patients with unprotected left main stenosis (UPLMS). There are still a lack of data r... Background Implantation of either bare metal stent (BMS) or drug-eluting stent (DES) has been used in every day practice for patients with unprotected left main stenosis (UPLMS). There are still a lack of data regading the subsequent results of UPLMS in-stent restenosis (ISR). The present study aimed at determing the clinical outcome of UPLMS ISR patients after implantation of either BMS or DES.Methods Patients with UPLMS ISR after stenting were included. The primary endpoint was the cumulative major adverse cardiac events (MACE), including cardiac death, myocardial infarction (Ml), and target vessel revascularization (TVR).Results UPLMS ISR rate was 14.8% (n=73, 15.7% after BMS, 14.5% for DES) after average of (3.89±2.01) years (range from 1 to 10.5 years) follow-up. Angiographic follow-up between 6-8 months was available in 85.3%. Of these,repeat percutaneous coronary intervention (PCI) was used in 62 (84.9%) patients, with medicine only in 9 (12.4%) and coronary artery bypass graft (CABG) in 2 (2.7%). Most repeat PCI patients were with unstable angina (87.0%), and had decreased left ventricular ejection fraction ((42.58±5.12)%), fewer focal/ostial left circumflex branch (LCX) lesions, in relative to medicine only group. After (31.9±23.3) months, the MACE, Ml, TVR and cardiac death were 31.5%, 1.4%, 24.1% and 8.2%, respectively. Definite and possible stent thrombosis occurred in 1 (1.4%) patient.Conclusions Medical therapy for asymptomatic isolated ostial LCX was safe. Repeat PCI for UPLMS ISR was associated with acceptable early and short-term clinical outcome. Further study was needed to elucidate the role of CABG in treating UPLMS ISR. 展开更多
关键词 unprotected left main stenosis in-stent restenosis percutaneous coronary intervention
原文传递
Luminometric Studies of Yeast Response to Complex Environmental Calcium Variations Demonstrate Sensing of External Calcium Ion Changes
7
作者 Augustus C. Parker David A. mintz +1 位作者 Francisco J. Solis Pamela A. Marshall 《Advances in Microbiology》 CAS 2022年第9期555-567,共13页
The response of yeast to sharp environmental increases in calcium concentration has been extensively studied. However, systematic studies of the response under more general changes are still lacking. Only limited expl... The response of yeast to sharp environmental increases in calcium concentration has been extensively studied. However, systematic studies of the response under more general changes are still lacking. Only limited exploration of cellular responses has been conducted where calcium concentration is decreased. This article describes a set of luminometric experiments that monitor the cytosolic calcium concentration under changing external concentration conditions. As a decrease in external calcium concentrations requires the use of large sample volumes, the experiments require the use of equipment adapted for this purpose. We describe the modification of commercial luminometric equipment to make the exploration possible. We explore the yeast cellular behavior when an increase in external calcium concentration is followed by a decrease in external calcium concentration. We compare these results with those from the case of a double pulse of concentration increase. Results from the experiment show that the first, concentration increasing pulse produces the well-known sharp increase in cytosolic calcium followed by calcium sequestration to return to a cytosolic concentration near its initial condition. Surprisingly, the calcium decrease step shows similar results with a cytosolic increase followed by a return to lower levels. The results suggest the presence of a calcium sensing mechanism regulating calcium influx from external sources. This mechanism would produce channel opening as a response to any changes in external concentration, be it an enhancement or a depletion. 展开更多
关键词 Saccharomyces cerevisiae CALCIUM HOMEOSTASIS Extracellular Ion Changes
下载PDF
A prospective study assessing the efficacy of abdominal computed tomography scan without bowel preparation in diagnosing intestinal wall and luminal lesions in patients presenting to the emergency room with abdominal complaints 被引量:2
8
作者 Michal Mizrahi Yoav mintz +5 位作者 Avraham Rivkind David Kisselgoff Eugene Libson Mayer Brezis Eran Goldin Oren Shibolet 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第13期1981-1986,共6页
AIM: To evaluate the positive predictive value of abdominal non-prepared computed tomography (CT) for diagnosing intestinal lumen or wall lesions in patients presenting to the emergency room (ER) with abdominal compla... AIM: To evaluate the positive predictive value of abdominal non-prepared computed tomography (CT) for diagnosing intestinal lumen or wall lesions in patients presenting to the emergency room (ER) with abdominal complaints.METHODS: For 1-year we prospectively evaluated all ER patients hospitalized after abdominal CT scan detected either intraluminal or intestinal wall lesions. These patients underwent colonoscopy serving as gold standard. Patients with prior abdominal pathology or CT findings of appendicitis or diverticulitis were excluded.RESULTS: Five hundred and sixty-eight abdominopelvic CT scans were performed in the ER, 96 had positive colonic findings. Sixty-two patients were excluded, 46 because of diverticulitis or appendicitis, 16 because of prior abdominal pathology. Of the remaining 34 patients, 14 did not undergo colonoscopy during hospitalization.Twenty eligible patients were included in the study. The positive predictive value of the CT scans performed in the ER was calculated to be 45% (95% CI 25-67).CONCLUSION: CT findings correlated with colonoscopic findings only in approximately half of the cases. Relying on non-prepared CT scan findings in planning patient management and colonoscopy may lead to unnecessary diagnostic work-ups. 展开更多
关键词 Abdominal computed tomography Intestinal lesions Emergency room
下载PDF
输血相关的急性肺损伤 被引量:2
9
作者 mintz PD +3 位作者 Lipton KS 赵国胜(节译) 贾苍松(校) 《国际输血及血液学杂志》 CAS 2007年第2期191-192,F0003,共3页
TRALI是美国目前最常见的输血引起死亡的原因,超过ABO不相容和细菌污染。虽然仍不知道美国TRALI的实际发生率,但随着认识的提高,文献中TRALI病例报告数量自1985年以来显著增加。但对输血引起的许多类似的临床并发症仍然缺乏了解。200... TRALI是美国目前最常见的输血引起死亡的原因,超过ABO不相容和细菌污染。虽然仍不知道美国TRALI的实际发生率,但随着认识的提高,文献中TRALI病例报告数量自1985年以来显著增加。但对输血引起的许多类似的临床并发症仍然缺乏了解。2004年4月,在加拿大的多伦多召开了一次题为“关于TRALI的认识”的交流讨论会议。由加拿大血液机构和Hma-Qubec发起会议,得到了国际输血协会下属的BEST(Biomedical Excellence for Safer Transfusion)委员会的支持。许多专家提供了资料,大约240人出席了会议,包括会议专业组的11名成员。他们广泛代表了内科和其他学科的专家,如输血医学、流行病学、免疫学、麻醉学、急救医学、伦理学以及定期捐血者和长期受血者。完整的会议记录已经发表。 展开更多
关键词 急性肺损伤 TRALI 血相 输血协会 临床并发症 细菌污染 病例报告 输血医学
原文传递
钒微合金钢的热塑性 被引量:2
10
作者 Banks K M Tuling A mintz B 《钢铁钒钛》 CAS 北大核心 2015年第5期63-68,共6页
低碳低氮微合金钢通常表现出抗横向开裂性能,而碳含量较高的微合金钢则不然。讨论了碳含量质量分数为0.05%~0.6%的含钒微合金钢的热塑性研究和工业经验。在不同碳含量的情况下,只要[V][N]乘积不超过1×10-3,添加的钒就能降低钢对... 低碳低氮微合金钢通常表现出抗横向开裂性能,而碳含量较高的微合金钢则不然。讨论了碳含量质量分数为0.05%~0.6%的含钒微合金钢的热塑性研究和工业经验。在不同碳含量的情况下,只要[V][N]乘积不超过1×10-3,添加的钒就能降低钢对横向开裂的敏感性。铌和钒的结合增加了800~900℃临界矫直温度范围内的热塑性,这一改善得益于钒和铌复合加入减缓了动态析出过程。在含钛钢中,最初在高温下生成的Ti N具有促进Ti Nb(C,N)沉淀粗化和降低对塑性不利的细小Nb V(C,N)沉淀体积分数的额外作用。还介绍了TWIP钢热塑性的最新结果以及含钒微合金钢连铸的工业经验。 展开更多
关键词 微合金钢 连铸 热塑性
原文传递
Comparison of paclitaxal vs. sirolimus eluting stents with bio-degradable polymer for the treatment of coronary bifurcation lesions: subgroup analysis from DKCRUSH-I and DKCRUSH-II studies 被引量:1
11
作者 CHEN Shao-liang Gary mintz +9 位作者 Teguh Santoso ZHANG Jun-jie YE Fei XU Ya-wei FU Qiang KAN Jing Chitprapai Paiboon ZHOU Yong DING Shi-qin Tak W Kwan 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第19期3382-3387,共6页
Background The difference in clinical outcome between paclitaxal-eluting stents (PES) and sirolimus-eluting stents with bio-degradable polymer (SES-BDP) for bifurcation lesions remains unclear. The present study a... Background The difference in clinical outcome between paclitaxal-eluting stents (PES) and sirolimus-eluting stents with bio-degradable polymer (SES-BDP) for bifurcation lesions remains unclear. The present study aimed to investigate the one-year clinical outcome after DK crush stenting using PES (maxusTM) MS. SES-BDP (ExcelTM) from our database. Methods A total of 275 patients (90 from the DKCRUSH-I and 185 from the DKCRUSH-II study) were studied. The primary endpoint was the occurrence of major adverse cardiac events (MACE) at 12 months; including cardiac death, myocardial infarction (MI), or target vessel revascularization (TVR). The rate of binary restenosis and stent thrombosis served as secondary endpoints. Results At follow-up, minimal luminal diameter (MLD) in the Taxus group was (2.11+0.66) mm, with resultant increased target lesion revascularization (TLR) 12.2% and TVR 14.4%, significantly different from the Excel group; (2.47±0.56) mm, P 〈0.001, 3.2%, P=0.006, 4.9%, P=0.019, respectively. As a result there was a significant difference in MACE between the Taxus (20.0%) and Excel (10.3%, P=0.038) groups. Overall stent thrombosis was monitored in 11 patients (4.0%), with five in the Excel group (2.7%) and six in the Taxus group (6.7%). All stent thrombosis in the Excel group was classified as early, and all were defined as late in the Taxus group. Conclusion The Excel stent had lower rate of stent thrombosis, TLR, TVR, and composite MACE at 12-month after an indexed stenting procedure, compared to the Taxus stent. 展开更多
关键词 paclitaxal-eluting stent sirolimus-eluting stent bio-degradable polymer coronary bifurcation lesions
原文传递
^(192)Ir射线治疗老年冠脉支架内再狭窄的机制和1年临床随访:系列血管内超声分析
12
作者 吴智勇 Gary S.mintz 《海南医学》 CAS 2003年第12期2-4,共3页
目的 探讨1 92 Ir对老年冠心病支架内再狭窄的 1年的临床疗效及机制。方法  99例老年冠心病支架内再狭窄病人经常规介入治疗后随机分为1 92 Ir治疗组和安慰剂组 ,在放疗后即刻和 6个月行血管内超声检查 ,分别测量支架、管腔及增生内... 目的 探讨1 92 Ir对老年冠心病支架内再狭窄的 1年的临床疗效及机制。方法  99例老年冠心病支架内再狭窄病人经常规介入治疗后随机分为1 92 Ir治疗组和安慰剂组 ,在放疗后即刻和 6个月行血管内超声检查 ,分别测量支架、管腔及增生内膜的内径和面积 ,并临床随访 1年 ,对所得参数进行统计学处理。结果  99例病人中 ,糖尿病 3 9.4%,有支架内再狭窄史 5 8.6%,弥漫性病变 68%,静脉桥病变 18.5 %;两组治疗前后及两组间支架内径和面积无显著性变化 ,两组间放疗后即刻各参数也无显著性变化。随访中 ,治疗组和安慰剂组的最小腔内径、最小腔内面积和平均腔内面积分别为 :2 .0 3± 0 .47与 1.5 9± 0 .65mm ,P <0 .0 0 1;4.3 0± 2 .0 0与 2 .81± 2 .5 6mm2 ,P =0 .0 0 6;6.47± 2 .5 3与 5 .0 3± 3 .82mm2 ,P =0 .0 94。治疗组与对照组平均新生内膜和新生内膜百分比分别为 2 .2 2± 1.2 6与 3 .3 7± 1.89,P =0 .0 11;3 5± 17%与 5 7± 2 3 %,P <0 .0 0 1。 6个月的再狭窄率 ,治疗组与对照组分别为 :2 4.71%与 78.6%,p <0 .0 1。临床随访 1年 ,治疗组与对照组主要的心脏事件、靶血管及靶病变再介入治疗分别为 73 .0 %与 48.6%,P =0 .0 2 7;2 3 .8%与 5 1.4%,P =0 .0 0 6;11.6%与 40 .97%,P =0 .0 0 7。结论? 展开更多
关键词 192^Ir射线 老年人 冠脉支架内再狭窄 作用机制 随访 血管内超声 放射疗法 冠心病
下载PDF
The changes of oligodendrocytes induced by anesthesia during brain development 被引量:1
13
作者 Danye Jiang Sanghee Lim +2 位作者 Minhye Kwak Yun Kyoung Ryu C.David mintz 《Neural Regeneration Research》 SCIE CAS CSCD 2015年第9期1386-1387,共2页
With the advent of modern techniques, drugs, and monitoring, general anesthesia has come to be considered an unlikely cause of harm, particularly for healthy patients. While this is largely true, newly emerging clinic... With the advent of modern techniques, drugs, and monitoring, general anesthesia has come to be considered an unlikely cause of harm, particularly for healthy patients. While this is largely true, newly emerging clinical and laboratory studies have sug- gested that exposure to anesthetic agents during early childhood may have long-lasting adverse effects on cognitive function. This concern has been the focus of intense study in the field of anesthesia research. A recent high-profile review by Rappaport et al. (2015) concluded that while many questions remain un- answered, there is strong evidence from laboratory studies that commonly used anesthetics interfere with brain development and that clinical studies suggest a correlation between early childhood exposure to these agents and subsequent effects on learning and cognition. The issue is of sufficient public health importance that a public-private partnership known as Smar- Tots (Strategies for Mitigating Anesthesia-Related Neurotoxicity in Tots) was developed by the FDA to study pediatric anesthetic neurotoxicity. The mechanism of injury underlying this phe- nomenon has yet to be fully elucidated, and there is evidence to suggest that anesthetics may have direct cytotoxic effects on neurons leading to cell death or suppressed neurogenesis (Strat- mann et al., 2010) and that they may interfere with key pro- cesses in neuronal growth and development that underlie brain circuit development (Wagner et al., 2014). 展开更多
关键词 The changes of oligodendrocytes induced by anesthesia during brain development
下载PDF
Hemobilia due to hepatic artery aneurysm as the presenting sign of fibro-muscular dysplasia 被引量:1
14
作者 Noam Shussman Yair Edden +2 位作者 Yoav mintz Anthony Verstandig Avraham I Rivkind 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第11期1797-1799,共3页
Fibro-muscular dysplasia(FMD)is a rare but well documented disease with multiple arterial aneurysms. The patients,usually women,present with various clinical manifestations according to the specific arteries that are ... Fibro-muscular dysplasia(FMD)is a rare but well documented disease with multiple arterial aneurysms. The patients,usually women,present with various clinical manifestations according to the specific arteries that are affected.Typical findings are aneurysmatic dilatations of medium-sized arteries.The renal and the internal carotid arteries are most frequently affected, but other anatomical sites might be affected too.The typical angiographic picture is that of a"string of beads". Common histological features are additionally described. Here we present a case of a 47-year-old woman,who was hospitalized due to intractable abdominal pain.A routine work-up revealed a liver mass near the portal vein.Before a definite diagnosis was reached,the patient developed massive upper gastrointestinal bleeding.In order to control the hemorrhage,celiac angiography was performed revealing features of FMD in several arteries, including large aneurysms of the hepatic artery.Active bleeding from one of these aneurysms into the biliary tree indicated selective embolization of the hepatic artery.The immediate results were satisfactory,and the 5 years follow-up revealed absence of any clinical symptoms. 展开更多
关键词 Fibro-muscular dysplasia HEMOBILIA Endovascular approach
下载PDF
节能,不仅仅是电机
15
作者 Rich mintz 陈廷炯 《软件》 2009年第11期26-28,共3页
在美国,电动机消耗了65%的工业用电。这些电量相当于全美每年产电量的20%,同时也制造了类似比例的二氧化碳排放量。要想让这种程度的能源消耗量出现些许的下降,就必须跳出高效能电动机的思维框架,而要从整个动力传动系统中寻找适当的途径。
关键词 能源消耗量 节能 电机 动力传动系统 工业用电 碳排放量 电动机 电量
下载PDF
血管内超声部分研究进展
16
作者 Ultrasound Gary S.mintz 李越 王青 《当代医学》 2000年第7期41-41,66,共2页
1 对冠状动脉粥样硬化及再狭窄的认识 Glagov及其同事在病理方面的研究表明,在动脉粥样硬化早期阶段,冠状动脉的正性重构(一种增加动脉面积的病理变化过程)起到了维持动脉内径的作用。这就解释了为何血管内超声(intravascular ul-trasou... 1 对冠状动脉粥样硬化及再狭窄的认识 Glagov及其同事在病理方面的研究表明,在动脉粥样硬化早期阶段,冠状动脉的正性重构(一种增加动脉面积的病理变化过程)起到了维持动脉内径的作用。这就解释了为何血管内超声(intravascular ul-trasound,IVUS)在冠心病病人“动脉造影正常” 展开更多
关键词 冠状动脉粥样硬化 血管内超声 冠状动脉再狭窄
下载PDF
Sirolimus-eluting stent fractures associated with aneurysm and very late stent thrombosis in the right coronary artery
17
作者 LIU Xuebo Gary S.mintz +1 位作者 Stéphane G.Carlier Martin B.Leon 《上海医学》 CAS CSCD 北大核心 2007年第S1期226-229,共4页
Although the occurrence of coronary stent fracture is rare, recent reports showed that stent fracture after sirolimus-eluting stent (SES) implantation may be associated with neointimal hyperplasia and restenosis. We r... Although the occurrence of coronary stent fracture is rare, recent reports showed that stent fracture after sirolimus-eluting stent (SES) implantation may be associated with neointimal hyperplasia and restenosis. We report two cases of stent fracture that occurred late after elective SES implantation into the right coronary artery (RCA) that were related to the aneurysm, restenosis, thrombosis, and vessel occlusion. 展开更多
关键词 STENT ANEURYSM eluting RESTENOSIS ELECTIVE implantation DISTAL occlusion longitudinal unstable
下载PDF
Perspectives on the rational integration of intravascular imaging and physiology into the current cath lab environment
18
作者 Gary S. mintz 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第6期1013-1018,共6页
It is now more than two decades since Nico Pijls and Bernard DeBruyne introduced fractional flow reserve (FFR) as a way to assess stenosis severity in the catheterization laboratory and since Paul Yock invented gray... It is now more than two decades since Nico Pijls and Bernard DeBruyne introduced fractional flow reserve (FFR) as a way to assess stenosis severity in the catheterization laboratory and since Paul Yock invented grayscale intravascular ultrasound (IVUS) that then spawned many second-generation intravascular imaging techniques such as (1) Virtual histology-IVUS (VH-IVUS) that uses both amplitude and radiofrequency ultrasound information to classify plaque as necrotic core, 展开更多
关键词 intravascular imaging PHYSIOLOGY cath lab environment
原文传递
辛伐他汀对冠状动脉病变部位重构的影响:连续的血管内超声研究
19
作者 Jensen L.O. Thayssen P. +1 位作者 mintz G.S. 罗亮 《世界核心医学期刊文摘(心脏病学分册)》 2007年第4期17-18,共2页
背景:冠状动脉重构的直接证据只能依据外弹性膜(EEM)和斑块面积的连续改变而获得。本研究旨在通过连续的血管内超声(IVUS)
关键词 冠状动脉病 血管内超声 斑块面积 斑块负荷 外弹性膜 低脂饮食
下载PDF
Sirolimus-eluting stent fractures associated with aneurysm and very late stent thrombosis in the right coronary artery
20
作者 Gary S.mintz Stéphane G.Carlier Martin B.Leon 《上海医学》 CAS CSCD 北大核心 2007年第z1期226-229,共4页
  Although the occurrence of coronary stent fracture is rare,recent reports showed that stent fracture after sirolimus-eluting stent(SES)implantation may be associated with neointimal hyperplasia and restenosis.We r...   Although the occurrence of coronary stent fracture is rare,recent reports showed that stent fracture after sirolimus-eluting stent(SES)implantation may be associated with neointimal hyperplasia and restenosis.We report two cases of stent fracture that occurred late after elective SES implantation into the right coronary artery(RCA)that were related to the aneurysm,restenosis,thrombosis,and vessel occlusion.…… 展开更多
关键词 IVUS Sirolimus-eluting stent fractures associated with aneurysm and very late stent thrombosis in the right coronary artery RCA FIGURE BMS
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部