Reproducibility of 3 mm-Slice-Thick Reconstruction of Paranasal Sinus Computed Tomography Scans
1
作者 Matti Karjalainen Anna Julkunen +7 位作者 Antti Markkola Prasun Dastidar Heini Huhtala mikko suvinen Anna-Maija Kuukka Markus Rautiainen Jura Numminen Sanna Toppila-Salmi 《Open Journal of Radiology》 2016年第1期39-48,共10页
Background: After the failure of medical treatment, the surgery of chronic rhinosinusitis (CRS) is planned according to endoscopic and paranasal sinus computed tomography (CT) findings. Objective: The aim of this pros... Background: After the failure of medical treatment, the surgery of chronic rhinosinusitis (CRS) is planned according to endoscopic and paranasal sinus computed tomography (CT) findings. Objective: The aim of this prospective study was to evaluate whether this study method might be eligible in studies aiming at radiation dose reduction. Sinus CT scans were chosen as a model because of the high variation of the radiological anatomy of surgically important sinonasal structures. We hypothesized that 3 mm-slice-thick reconstruction CT had poor reproducibility. Methods: 59 CRS patients underwent routine multi-detector sinus CT (CT<sub>MD</sub>). CT<sub>3mm</sub> was reconstructed from CT<sub>MD</sub> data-sets. Lund-Mackay (LM) scores and 43 other structural parameters were analyzed blinded. Agreement was studied between CT<sub>MD</sub> and CT<sub>3mm</sub> (intra-observer reproducibility), and between three observers (inter-observer reproducibility) by using Cohen’s kappa. Results: The inter-observer agreement was moderate (kappa 0.4 - 0.6, p < 0.01) in the majority of structures of CT<sub>3mm</sub> scans. The intra-observer reproducibility of CT<sub>3mm</sub> scans was very good in most structures, however, it was poor in important structures such as frontal and spheno-ethmoid recess, lamina papyracae, and location of optic nerve or anterior ethmoidal artery. The grade of surgeon’s confidence of CT<sub>3mm</sub> in comparison to CT<sub>MD</sub> was lower (kappa 0.2 - 0.4, P < 0.05). Conclusion: This methodology might have some use in studies aiming at radiation dose reduction. As was expected, 3 mm-slice-thick reconstruction CT had poor reproducibility and surgeon’s confidence. More recent methods such as cone beam computed tomography scans have nowadays more relevant dose reduction potential. 展开更多
关键词 Chronic Rhinosinusitis Computed Tomography Image Reconstruction Inter-Observer Agreement Intra-Observer Agreement KAPPA Radiation-Dose Reduction REPRODUCIBILITY Paranasal Sinus Sinus Imaging
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部