期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Start-up performances of dry anaerobic mesophilic and thermophilic digestions of organic solid wastes 被引量:19
1
作者 LU Shu-guang IMAI Tsuyoshi +1 位作者 ukita Masao SEKINE Masahiko 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第4期416-420,共5页
Two dry anaerobic digestions of organic solid wastes were conducted for 6 weeks in a lab-scale batch experiment for investigating the start-up performances under mesophilic and thermophilic conditions. The enzymatic a... Two dry anaerobic digestions of organic solid wastes were conducted for 6 weeks in a lab-scale batch experiment for investigating the start-up performances under mesophilic and thermophilic conditions. The enzymatic activities, i.e., β-glucosidase, N-α-benzoyl-Largininamide (BAA)-hydrolysing protease, urease and phosphatase activities were analysed. The BAA-hydrolysing protease activity during the first 2-3 weeks was low with low pH, but was enhanced later with the pH increase. β-Glucosidase activity showed the lowest values in weeks 1-2, and recovered with the increase of BAA-hydrolysing protease activity. Acetic acid dominated most of the total VFAs in thermophilic digestion, while propionate and butyrate dominated in mesophilic digestion. Thermophilic digestion was confirmed more feasible for achieving better performance against misbalance, especially during the start-up period in a dry anaerobic digestion process. 展开更多
关键词 anaerobic digestion enzymatic activity MESOPHILIC solid wastes THERMOPHILIC
下载PDF
铁道车辆用非接触供电系统的电能传输性能验证 被引量:1
2
作者 Keigo ukita 周贤全 《国外铁道车辆》 2017年第5期19-23,共5页
概述了铁道车辆用非接触供电系统(NPS)的结构特点,并对NPS样机进行了测试,测试结果表明,NPS作为铁道车辆用电源是有效的。
关键词 铁道车辆 NPS 日本
下载PDF
Modeling of residual chlorine in water distribution system 被引量:4
3
作者 LIXin M.ukita 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第1期136-144,共9页
Water quality within water distribution system may vary with both location and time. Water quality models are used to predict the spatial and temporal variation of water quality throughout water system. A model of res... Water quality within water distribution system may vary with both location and time. Water quality models are used to predict the spatial and temporal variation of water quality throughout water system. A model of residual chlorine decay in water pipe has been developed, given the consumption of chlorine in reactions with chemicals in bulk water, bio films on pipe wall, in corrosion process, and the mass transport of chlorine from bulk water to pipe wall. Analytical methods of the flow path from water sources to the observed point and the water age of every observed node were proposed. Model is used to predict the decay of residual chlorine in an actual distribution system. Good agreement between calculated and measured values was obtained. 展开更多
关键词 residual chlorine bulk water CORROSION bio film water quality water distribution system flow path water age
下载PDF
Treating bilio-duodenal obstruction: Combining new endoscopic technique with 6 Fr stent introducer 被引量:2
4
作者 Iruru Maetani Tomoko Nambu +2 位作者 Shigefumi Omuta Takeo ukita Hiroaki Shigoka 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第22期2828-2831,共4页
Periampullary cancer may cause not only biliary but also duodenal obstructions. In patients with concomitant duodenal obstructions, endoscopic biliary stenting remains technically difficult and may often require percu... Periampullary cancer may cause not only biliary but also duodenal obstructions. In patients with concomitant duodenal obstructions, endoscopic biliary stenting remains technically difficult and may often require percutaneous transhepatic biliary drainage. We describe a method of metal stent placement via a thin forwardviewing endoscope in patients with simultaneous biliary and duodenal obstruction. In two consecutive patients with biliary and duodenal obstruction due to pancreatic cancer, a new biliary metal stent mounted in a slim delivery catheter was placed via a thin forward viewing endoscope after passage across the duodenal stenosis without balloon dilation. In both patients, with our new placement technique, metallic stents were successfully placed in a short time without adverse events. After biliary stenting, one patient received curative resection and the other received duodenal stenting for palliation. Metallic stent placement with a forward-viewing thin endoscope is a beneficial technique, which can avoid percutaneous drainage in patients with bilio-duodenal obstructions due to periampullary cancer. 展开更多
关键词 Biliary obstruction Duodenal obstruction Pancreatic cancer Self-expandable metallic stent Stent placement Thin forward-viewing endoscope
下载PDF
Direct peroral cholangioscopy using an ultraslim upper endoscope for biliary lesions 被引量:1
5
作者 Shigefumi Omuta Iruru Maetani +5 位作者 Takeo ukita Tomoko Nambu Katsushige Gon Hiroaki Shigoka Yoshinori Saigusa Michihiro Saito 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2014年第1期60-64,共5页
BACKGROUND: The development of direct peroral cholangioscopy(DPOC) using an ultraslim endoscope simplifies biliary cannulation. The conventional techniques are cumbersome to perform and require advanced skills. The re... BACKGROUND: The development of direct peroral cholangioscopy(DPOC) using an ultraslim endoscope simplifies biliary cannulation. The conventional techniques are cumbersome to perform and require advanced skills. The recent introduction of the guidewires and balloons has improved the therapeutic outcomes. Here we describe an effective and easier method for performing DPOC using an ultraslim upper endoscope. METHODS: Indications for DPOC were the presence of stones on follow-up of patients who had previously undergone complete sphincteroplasty, including endoscopic sphincterotomy or endoscopic papillary large balloon dilatation. Fifteen patients underwent DPOC. An ultraslim endoscope was inserted perorally and was advanced into the major papilla. The ampulla of Vater was visualized by retroflexing the endoscope in the distal second portion of the duodenum, and then DPOC was performed using a wire-guided cannulation technique with an anchored intraductal balloon catheter. RESULTS: One patient failed in the treatment due to looping of the endoscope in the fornix of the stomach. Fourteen(93.3%) were successfully treated with our modified DPOC technique. Only one patient(6.7%) experienced an adverse event(pancreatitis) who responded well to conservative management. Residual stones of the common bile duct were completely removed in 3 patients. CONCLUSION: The modified method of DPOC is simple, safe and easy to access the bile duct. 展开更多
关键词 direct peroral cholangioscopy ultraslim upper endoscope endoscopic retrograde cholangioscopy biliary tract
下载PDF
A Note on Relation between the Fourier Coefficients and the Effects in the Experimental Design 被引量:1
6
作者 Yoshifumi ukita Toshiyasu Matsushima 《通讯和计算机(中英文版)》 2012年第7期830-836,共7页
关键词 傅里叶变换 实验设计 系数和 傅里叶系数 注记 傅立叶系数 系统 模型
下载PDF
Relation between the Fourier Coefficients and the Interaction Effects in the Experimental Design
7
作者 Yoshifumi ukita Toshiyasu Matsushima Shigeichi Hirasawa 《通讯和计算机(中英文版)》 2013年第2期169-177,共9页
关键词 傅立叶系数 实验设计 互动效应 傅里叶变换 相互作用 交互效应 傅立叶变换 三因子
下载PDF
Arteriovenous malformation of the vestibulocochlear nerve
8
作者 Adam Tucker Masao Tsuji +4 位作者 Yoshitaka Yamada Kenichiro Hanabusa Tohru ukita Hiroji Miyake Takehisa Ohmura 《World Journal of Clinical Cases》 SCIE 2015年第7期661-670,共10页
We describe a rare case of an arteriovenous malformation(AVM) embedded in the vestibulocochlear nerve presenting with subarachnoid hemorrhage(SAH) treated by microsurgical elimination of the main feeding artery and pa... We describe a rare case of an arteriovenous malformation(AVM) embedded in the vestibulocochlear nerve presenting with subarachnoid hemorrhage(SAH) treated by microsurgical elimination of the main feeding artery and partial nidus volume reduction with no permanent deficits. This 70-year-old woman was incidentally diagnosed 4 years previously with two small unruptured tandem aneurysms(ANs) on the right anterior inferior cerebral artery feeding a small right cerebellopontine angle AVM. The patient was followed conservatively until she developed sudden headache, nausea and vomiting and presented to our outpatient clinic after several days. Magnetic resonance imaging demonstrated findings suggestive of early subacute SAH in the quadrigeminal cistern. A microsurgical flow reduction technique via clipping between the two ANs and partial electrocoagulation of the nidus buried within the eighth cranial nerve provided radiographical devascularization of the ANs with residual AVM shunt flow and no major deficits during the 2.5 year follow-up. This is only the second report of an auditory nerve AVM. In the event of recurrence, reoperation or application of alternative therapies may be considered. 展开更多
关键词 ARTERIOVENOUS MALFORMATION Flow reduction MICROSURGERY SUBARACHNOID HEMORRHAGE Vestibulocochlear NERVE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部