期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Simulation of electron behavior in PIG ion source for 9 MeV cyclotron 被引量:1
1
作者 X.J.Mu M.ghergherehchi +2 位作者 Y.H.Yeon J.W.Kim J.S.Chai 《Chinese Physics C》 SCIE CAS CSCD 2014年第12期70-76,共7页
In this paper, we focus on a PIG source for producing intense H-ions inside a 9 MeV cyclotron. The properties of the PIG ion source were simulated for a variety of electric field distributions and magnetic field stren... In this paper, we focus on a PIG source for producing intense H-ions inside a 9 MeV cyclotron. The properties of the PIG ion source were simulated for a variety of electric field distributions and magnetic field strengths using a CST particle studio. After analyzing the secondary electron emission(SEE) as a function of both magnetic and electric field strengths, we found that for the modeled PIG geometry, a magnetic field strength of 0.2 T provided the best results in terms of the number of secondary electrons. Furthermore, at 0.2 T, the number of secondary electrons proved to be greatest regardless of the cathode potential. Also, the modified PIG ion source with quartz insulation tubes was tested in a KIRAMS-13 cyclotron by varying the gas flow rate and arc current, respectively.The capacity of the designed ion source was also demonstrated by producing plasma inside the constructed 9 MeV cyclotron. As a result, the ion source is verified as being capable of producing an intense H-beam and high ion beam current for the desired 9 MeV cyclotron. The simulation results provide experimental constraints for optimizing the strength of the plasma and final ion beam current at a target inside a cyclotron. 展开更多
关键词 PIG ion source CST particle studio electromagnetic field secondary electron gas flow rate arc
原文传递
Optimized feed-forward neural-network algorithm trained for cyclotron-cavity modeling
2
作者 Masoumeh Mohamadian Hossein Afarideh Mitra ghergherehchi 《Chinese Physics C》 SCIE CAS CSCD 2017年第1期180-186,共7页
The cyclotron cavity presented in this paper is modeled by a feed-forward neural network trained by the authors' optimized back-propagation(BP) algorithm. The training samples were obtained from simulation results ... The cyclotron cavity presented in this paper is modeled by a feed-forward neural network trained by the authors' optimized back-propagation(BP) algorithm. The training samples were obtained from simulation results that are for a number of defined situations and parameters and were achieved parametrically using MWS CST software; furthermore, the conventional BP algorithm with different hidden-neuron numbers, structures, and other optimal parameters such as learning rate that are applied for our purpose was also used here. The present study shows that an optimized FFN can be used to estimate the cyclotron-model parameters with an acceptable error function. A neural network trained by an optimized algorithm therefore shows a proper approximation and an acceptable ability regarding the modeling of the proposed structure. The cyclotron-cavity parameter-modeling results demonstrate that an FNN that is trained by the optimized algorithm could be a suitable method for the estimation of the design parameters in this case. 展开更多
关键词 cyclotron cavity CST modeling neural network
原文传递
Polyethylene glycol has immunoprotective effects on sciatic allografts, but behavioral recovery and graft tolerance require neurorrhaphy and axonal fusion
3
作者 Tyler A.Smith Liwen Zhou +6 位作者 Cameron L.ghergherehchi Michelle Mikesh Cathy Z.Yang Haley O.Tucker JuliAnne Allgood Jared S.Bushman George D.Bittner 《Neural Regeneration Research》 SCIE CAS 2025年第4期1192-1206,共15页
Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripher... Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripheral nerve allografts undergo immunological rejection by the host immune system.In contrast,peripheral nerve injuries repaired by polyethylene glycol fusion of peripheral nerve allografts exhibit excellent behavioral recovery within weeks,reduced immune responses,and many axons do not undergo Wallerian degeneration.The relative contribution of neurorrhaphy and polyethylene glycol-fusion of axons versus the effects of polyethylene glycol per se was unknown prior to this study.We hypothesized that polyethylene glycol might have some immune-protective effects,but polyethylene glycol-fusion was necessary to prevent Wallerian degeneration and functional/behavioral recovery.We examined how polyethylene glycol solutions per se affect functional and behavioral recovery and peripheral nerve allograft morphological and immunological responses in the absence of polyethylene glycol-induced axonal fusion.Ablation-type sciatic nerve injuries in outbred Sprague–Dawley rats were repaired according to a modified protocol using the same solutions as polyethylene glycol-fused peripheral nerve allografts,but peripheral nerve allografts were loose-sutured(loose-sutured polyethylene glycol)with an intentional gap of 1–2 mm to prevent fusion by polyethylene glycol of peripheral nerve allograft axons with host axons.Similar to negative control peripheral nerve allografts not treated by polyethylene glycol and in contrast to polyethylene glycol-fused peripheral nerve allografts,animals with loose-sutured polyethylene glycol peripheral nerve allografts exhibited Wallerian degeneration for all axons and myelin degeneration by 7 days postoperatively and did not recover sciatic-mediated behavioral functions by 42 days postoperatively.Other morphological signs of rejection,such as collapsed Schwann cell basal lamina tubes,were 展开更多
关键词 allograft rejection AXOTOMY macrophage MYELIN nerve repair polyethylene glycol(PEG) sciatic nerve T cell transplantation Wallerian degeneration
Conundrums and confusions regarding how polyethylene glycol-fusion produces excellent behavioral recovery after peripheral nerve injuries 被引量:4
4
作者 George D.Bittner Dale R.Sengelaub Cameron L.ghergherehchi 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第1期53-57,共5页
Current Neuroscience dogma holds that transections or ablations of a segment of peripheral nerves produce: (1) Immediate loss of axonal continuity, sensory signaling, and motor control; (2) Wallerian rapid (1-3 ... Current Neuroscience dogma holds that transections or ablations of a segment of peripheral nerves produce: (1) Immediate loss of axonal continuity, sensory signaling, and motor control; (2) Wallerian rapid (1-3 days) degeneration of severed distal axons, muscle atrophy, and poor behavioral recovery after many months (if ever, after ablations) by slowly-regenerating (1 mm/d), proximal-stump outgrowths that must specifically reinnervate denervated targets; (3) Poor acceptance of microsutured nerve allografts, even if tissue-matched and immune-suppressed. Repair of transections/ablations by neurorrhaphy and well-specified-sequences of PEG-fusion solutions (one containing polyethylene glycol, PEG) successfully address these problems. However, conundrums and confusions regarding unorthodox and dramatic results of PEG-fusion repair in animal model systems often lead to misunderstandings. For example, (1) Axonal continuity and signaling is re-established within minutes by non-specifically PEG-fusing (connecting) severed motor and sensory axons across each lesion site, but remarkable behavioral recovery to near-unoperated levels takes several weeks; (2) Many distal stumps of inappropriately-reconnected, PEG-fused axons do not ever (Wallerian) degenerate and continuously innervate muscle fibers that undergo much less atrophy than otherwise-denervated muscle fibers; (3) Host rats do not reject PEG-fused donor nerve allografts in a non-immuno-privileged environment with no tissue matching or immunosuppression; (4) PEG fuses apposed open axonal ends or seals each shut (thereby preventing PEG-fusion), depending on the experimental protocol; (5) PEG-fusion protocols produce similar results in animal model systems and early human case studies. Hence, iconoclastic PEG-fusion data appropriately understood might provoke a re-thinking of some Neuroscience dogma and a paradigm shift in clinical treatment of peripheral nerve injuries. 展开更多
关键词 axonal repair AXOTOMY Wallerian degeneration polyethylene glycol ALLOGRAFT AUTOGRAFT nerve regeneration
下载PDF
Methylene blue enhances polyethylene glycol-fusion repair of completely severed rat sciatic nerves 被引量:2
5
作者 Cameron L.ghergherehchi Jaimie T.Shores +2 位作者 Joseph Alderete Erik K.Weitzel George D.Bittner 《Neural Regeneration Research》 SCIE CAS CSCD 2021年第10期2056-2063,共8页
Complete transection of peripheral mixed nerves immediately produces loss of sensory perception,muscle contractions and voluntary behavior mediated by the severed distal axons.In contrast to natural regeneration(~1 mm... Complete transection of peripheral mixed nerves immediately produces loss of sensory perception,muscle contractions and voluntary behavior mediated by the severed distal axons.In contrast to natural regeneration(~1 mm/d)of proximal axons that may eventually reinnervate denervated targets,re-innervation is restored within minutes by PEG-fusion that consists of neurorrhaphy and a sequence of well specified hypo-and isotonic calcium-free or calcium-containing solutions,the anti-oxidant methylene blue(MB)and the membrane fusogen polyethylene glycol(PEG).In this study,we examined the relative efficacy of PEG-fusion with no MB(0%),0.5%MB,or 1%MB on the recovery of voluntary behaviors by female Sprague-Dawley rats with a complete mid-thigh severance of their sciatic nerve bathed in extracellular fluid or calcium-containing isotonic saline.The recovery of voluntary behaviors is the most relevant measure of success of any technique to repair peripheral nerve injuries.We assessed recovery by the sciatic functional index,a commonly used measure of voluntary hindlimb behaviors following complete sciatic transections.We reported that both 1%MB and 0.5%MB in sterile distilled water in our PEG-fusion protocol with neurorrhaphy significantly increased the rate and extent of behavioral recovery compared to PEG plus neurorrhaphy alone.Furthermore,0.5%MB was as effective as 1%MB in voluntary behavioral recovery as assessed by the sciatic functional index.Since sterile 1%MB is no longer clinically available,we therefore recommend that 0.5%MB be included in upcoming human clinical trials to evaluate the safety and efficacy of PEG-fusion.All animal procedures were approved by the University of Texas Institutional Animal Care and Use Committee(AUP-2019-00225)on September 9,2020. 展开更多
关键词 AXOTOMY methylene blue nerve repair NEURORRHAPHY peripheral nerve injury polyethylene glycol fusion sciatic nerve
下载PDF
Intelligent low-level RF system by non-destructive beam monitoring device for cyclotrons 被引量:1
6
作者 M.S.Sharifi Asadi Malafeh M.ghergherehchi +2 位作者 H.Afarideh J.S.Chai Yoon Sang Kim 《Chinese Physics C》 SCIE CAS CSCD 2016年第4期98-105,共8页
The project of a 10 Me V PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of the cyclotron accelerator is designed to sta... The project of a 10 Me V PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of the cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work an Intelligent Low Level Radio Frequency Circuit or ILLRF, suitable for most AVF cyclotron accelerators, is designed using a beam monitoring device and narrow band tunable band-pass filter. In this design, the RF phase detection does not need signal processing by a microcontroller. 展开更多
关键词 accelerator destructive stabilize tunable resonant acceleration narrow adjust bunch correction
原文传递
Polyethylene glycol-fusion retards Wallerian degeneration and rapidly restores behaviors lost after nerve severance
7
作者 George D.Bittner Michelle Mikesh Cameron L.ghergherehchi 《Neural Regeneration Research》 SCIE CAS CSCD 2016年第2期217-219,共3页
Some biological uses of polyethylene glycol(PEG):The use of PEG as a membrane fusogen was first reported in 1976with the creation of cell hybrids,formed by suspending two cell lines in a 50%w/w solution of PEG in w... Some biological uses of polyethylene glycol(PEG):The use of PEG as a membrane fusogen was first reported in 1976with the creation of cell hybrids,formed by suspending two cell lines in a 50%w/w solution of PEG in water. 展开更多
关键词 FIGURE PEG Polyethylene glycol-fusion retards Wallerian degeneration and rapidly restores behaviors lost after nerve severance
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部