There has recently been a dramatic renewal of interest in hadron spectroscopy and charm physics. This renaissance has been driven in part by the discovery of a plethora of charmonium-like XYZ states at BESⅢ and B fac...There has recently been a dramatic renewal of interest in hadron spectroscopy and charm physics. This renaissance has been driven in part by the discovery of a plethora of charmonium-like XYZ states at BESⅢ and B factories, and the observation of an intriguing proton-antiproton threshold enhancement and the possibly related X(1835) meson state at BESⅢ, as well as the threshold measurements of charm mesons and charm baryons. We present a detailed survey of the important topics in tau-charm physics and hadron physics that can be further explored at BESⅢ during the remaining operation period of BEPCⅡ. This survey will help in the optimization of the data-taking plan over the coming years, and provides physics motivation for the possible upgrade of BEPCⅡ to higher luminosity.展开更多
From 2011 to 2014, the BESIII experiment collected about 5 fb^-1 data at center-of-mass energies around 4 GeV for the studies of the charmonium-like and higher excited charmonium states. By analyzing the di-muon proce...From 2011 to 2014, the BESIII experiment collected about 5 fb^-1 data at center-of-mass energies around 4 GeV for the studies of the charmonium-like and higher excited charmonium states. By analyzing the di-muon process e+e- →yma/Fsμ^+μ^-, the center-of-mass energies of the data samples are measured with a precision of 0.8 MeV. The center-of-mass energy is found to be stable for most of the time during data taking.展开更多
Using a dedicated data sample taken in 2018 on the J/ψpeak,we perform a detailed study of the trigger efficiencies of the BESIII detector.The efficiencies are determined from three representative physics processes,na...Using a dedicated data sample taken in 2018 on the J/ψpeak,we perform a detailed study of the trigger efficiencies of the BESIII detector.The efficiencies are determined from three representative physics processes,namely Bhabha scattering,dimuon production and generic hadronic events with charged particles.The combined efficiency of all active triggers approaches 100%in most cases,with uncertainties small enough not to affect most physics analyses.展开更多
The peripheral nerve injuries,representing some of the most common types of traumatic lesions affecting the nervous system,are highly invalidating for the patients besides being a huge social burden.Although periphera...The peripheral nerve injuries,representing some of the most common types of traumatic lesions affecting the nervous system,are highly invalidating for the patients besides being a huge social burden.Although peripheral nervous system owns a higher regenerative capacity than does central nervous system,mostly depending on Schwann cells intervention in injury repair,several factors determine the extent of functional outcome after healing.Based on the injury type,different therapeutic approaches have been investigated so far.Nerve grafting and Schwann cell transplantation have represented the gold standard treatment for peripheral nerve injuries,however these approaches own limitations,such as scarce donor nerve availability and donor site morbidity.Cell based therapies might provide a suitable tool for peripheral nerve regeneration,in fact,the ability of different stem cell types to differentiate towards Schwann cells in combination with the use of different scaffolds have been widely investigated in animal models of peripheral nerve injuries in the last decade.Dental pulp is a promising cell source for regenerative medicine,because of the ease of isolation procedures,stem cell proliferation and multipotency abilities,which are due to the embryological origin from neural crest.In this article we review the literature concerning the application of tooth derived stem cell populations combined with different conduits to peripheral nerve injuries animal models,highlighting their regenerative contribution exerted through either glial differentiation and neuroprotective/neurotrophic effects on the host tissue.展开更多
Fecal calprotectin(FC) has emerged as one of the most useful tools for clinical management of inflammatory bowel diseases(IBD). Many different methods of assessment have been developed and different cutoffs have been ...Fecal calprotectin(FC) has emerged as one of the most useful tools for clinical management of inflammatory bowel diseases(IBD). Many different methods of assessment have been developed and different cutoffs have been suggested for different clinical settings. We carried out a comprehensive literature review of the most relevant FC-related topics: the role of FC in discriminating between IBD and irritable bowel syndrome(IBS) and its use in managing IBD patients In patients with intestinal symptoms, due to the high negative predictive value a normal FC level reliably rules out active IBD. In IBD patients a correlation with both mucosal healing and histology was found, and there is increasing evidence that FC assessment can be helpful in monitoring disease activity and response to therapy as well as in predicting relapse, post-operative recurrence or pouchitis. Recently, its use in the context of a treat-to-target approach led to a better outcome than clinically-based therapy adjustment in patients with early Crohn's disease. In conclusion, FC measurement represents a cheap, safe and reliable test, easy to perform and with a good reproducibility. The main concerns are still related to the choice of the optimal cut-off, both for differentiating IBD from IBS, and for the management of IBD patients.展开更多
Gastroesophageal reflux disease(GERD) is a common disorder of the gastrointestinal tract. In the last few decades, new technologies have evolved and have been applied to the functional study of the esophagus, allowing...Gastroesophageal reflux disease(GERD) is a common disorder of the gastrointestinal tract. In the last few decades, new technologies have evolved and have been applied to the functional study of the esophagus, allowing for the improvement of our knowledge of the pathophysiology of GERD. High-resolution manometry(HRM) permits greater understanding of the function of the esophagogastric junction and the risks associated with hiatal hernia. Moreover, HRM has been found to be more reproducible and sensitive than conventional water-perfused manometry to detect the presence of transient lower esophageal sphincter relaxation. Esophageal 24-h p H-metry with or without combined impedance is usually performed in patients with negative endoscopy and reflux symptoms who have a poor response to anti-reflux medical therapy to assess esophageal acid exposure and symptom-reflux correlations. In particular, esophageal 24-h impedance and p H monitoring can detect acid and non-acid reflux events. Endo FLIP is a recent technique poorly applied in clinical practice, although it provides a large amount of information about the esophagogastric junction. In the coming years, laryngopharyngeal symptoms could be evaluated with up and coming non-invasive or minimally invasive techniques, such as pepsin detection in saliva or pharyngeal p H-metry. Future studies are required of these techniques to evaluate their diagnostic accuracy and usefulness, although the available data are promising.展开更多
The small bowel has long been considered a black box for endoscopists because of its long length and the presence of multiple complex loop. Most of the small bowel is inaccessible by traditional endoscopic means. In ... The small bowel has long been considered a black box for endoscopists because of its long length and the presence of multiple complex loop. Most of the small bowel is inaccessible by traditional endoscopic means. In addition, radiographic studies have significant limitations with regard to diagnostic yield, and surgery is an invasive alternative. This limitation was overcome through the development of balloon enteroscopy that becomes established throughout the world for diagnostic and therapeutic examinations of the small bowel. The single-balloon enteroscope (SBE) system (Olympus, Tokyo, Japan) was introduced into the commercial market in 2007. Several study demonstrated its efficacy and safety. Early reports on the use of singleballoon enteroscopy have suggested a high diagnostic yield and similar therapeutic potential to that of the double-balloon endoscope. SBE is viable technique for in the management of small bowel disease. Technically, it is easy to perform, may be efficient, and in the literature data available, seems to provide high diagnostic and therapeutic yield.展开更多
In the last decades many advances have been achieved in endoscopy, in the diagnosis and therapy of cholangiocarcinoma, however blood test, magnetic resonance imaging, computed tomography scan may fail to detect neopla...In the last decades many advances have been achieved in endoscopy, in the diagnosis and therapy of cholangiocarcinoma, however blood test, magnetic resonance imaging, computed tomography scan may fail to detect neoplastic disease at early stage, thus the diagnosis of cholangiocarcinoma is achieved usually at unresectable stage. In the last decades the role of endoscopy has moved from a diagnostic role to an invaluable therapeutic tool for patients affected by malignant bile duct obstruction. One of the major issues for cholangiocarcinoma is bile ducts occlusion, leading to jaundice, cholangitis and hepatic failure. Currently, endoscopy has a key role in the work up of cholangiocarcinoma, both in patients amenable to surgical intervention as well as in those unfit for surgery or not amenable to immediate surgical curative resection owing to locally advanced or advanced disease, with palliative intention. Endoscopy allows successful biliary drainage and stenting in more than 90% of patients with malignant bile duct obstruction, and allows rapid reduction of jaundice decreasing the risk of biliary sepsis. When biliary drainage and stenting cannot be achieved with endoscopy alone, endoscopic ultrasound-guided biliary drainage represents an effective alternative method affording successful biliary drainage in more than 80% of cases. The purpose of this review is to focus on the currently available endoscopic management options in patients with cholangiocarcinoma.展开更多
We present a measurement of the integrated luminosity of e^(+)e^(-)collision data collected by the BESIII detector at the BEPCII collider at a center-of-mass energy of Ecm=3.773 GeV.The integrated luminosities of the ...We present a measurement of the integrated luminosity of e^(+)e^(-)collision data collected by the BESIII detector at the BEPCII collider at a center-of-mass energy of Ecm=3.773 GeV.The integrated luminosities of the datasets taken from December 2021 to June 2022,from November 2022 to June 2023,and from October 2023 to February 2024 were determined to be 4.995±0.019 fb^(-1),8.157±0.031 fb^(-1),and 4.191±0.016 fb^(-1),respectively,by analyzing large angle Bhabha scattering events.The uncertainties are dominated by systematic effects,and the statistical uncertainties are negligible.Our results provide essential input for future analyses and precision measurements.展开更多
The number ofψ(3686)events collected by the BESⅢdetector during the 2021 run period is determined to be(2259.3±11.1)×10~6 by counting inclusiveψ(3686)hadronic events.The uncertainty is systematic and the ...The number ofψ(3686)events collected by the BESⅢdetector during the 2021 run period is determined to be(2259.3±11.1)×10~6 by counting inclusiveψ(3686)hadronic events.The uncertainty is systematic and the statistical uncertainty is negligible.Meanwhile,the numbers ofψ(3686)events collected during the 2009 and 2012run periods are updated to be(107.7±0.6)×10~6 and(345.4±2.6)×10~6,respectively.Both numbers are consistent with the previous measurements within one standard deviation.The total number ofψ(3686)events in the three data samples is(2712.4±14.3)×10~6.展开更多
AIM:To assess linear endoscopic ultrasound (L-EUS) and magnetic resonance imaging (MRI) in biliary tract dilation and suspect small ampullary tumor.METHODS:L-EUS and MRI data were compared in 24 patients with small am...AIM:To assess linear endoscopic ultrasound (L-EUS) and magnetic resonance imaging (MRI) in biliary tract dilation and suspect small ampullary tumor.METHODS:L-EUS and MRI data were compared in 24 patients with small ampullary tumors;all with subsequent histological confirmation.Data were collected prospectively and the accuracy of detection,histological characterization and N staging were assessed retrospectivelyusing the results of surgical or endoscopic treatment as a benchmark.RESULTS:A suspicion of ampullary tumor was present in 75% of MRI and all L-EUS examinations,with 80% agreement between EUS and histological findings at endoscopy.However,L-EUS and histological TN staging at surgery showed moderate agreement (κ=0.54).CONCLUSION:L-EUS could be a useful adjunct as a diagnostic tool in the evaluation of patients with sus-pected ampullary tumors.展开更多
This editorial is a commentary on the case report by Furuya et al focusing on the challenging diagnosis of early pancreatic adenocarcinoma and new tools for an earlier diagnosis.Currently,pancreatic cancer still has a...This editorial is a commentary on the case report by Furuya et al focusing on the challenging diagnosis of early pancreatic adenocarcinoma and new tools for an earlier diagnosis.Currently,pancreatic cancer still has a poor prognosis,mainly due to late diagnosis in an advanced stage.Two main precancerous routes have been identified as pathways to pancreatic adenocarcinoma:The first encompasses a large group of mucinous cystic lesions:intraductal papillary mucinous neoplasm and mucinous cystic neoplasm,and the second is pancreatic intraepithelial neoplasia.In the last decade the focus of research has been to identify high-risk patients,using advanced imaging techniques(magnetic resonance cholangiopancreatography or endoscopic ultrasonography)which could be helpful in finding“indirect signs”of early stage pancreatic lesions.Nevertheless,the survival rate still remains poor,and alternative screening methods are under investigation.Endoscopic retrograde cholangiopancreatography followed by serial pancreatic juice aspiration cytology could be a promising tool for identifying precursor lesions such as intraductal papillary mucinous neoplasm,but confirming data are still needed to validate its role.Probably a combination of cross-sectional imaging,endoscopic techniques(old and new ones)and genetic and biological biomarkers also in pancreatic juice)could be the best solution to reach an early diagnosis.Biomarkers could help to predict and follow the progression of early pancreatic lesions.However,further studies are needed to validate their diagnostic reliability and to establish diagnostic algorithms to improve prognosis and survival in patients with pancreatic cancer.展开更多
Irritable bowel syndrome(IBS) and functional constipation(FC) are the most common functional gastrointestinal disorders. According to the Rome ⅢCriteria these two disorders should be theoretically separated mainly by...Irritable bowel syndrome(IBS) and functional constipation(FC) are the most common functional gastrointestinal disorders. According to the Rome ⅢCriteria these two disorders should be theoretically separated mainly by the presence of abdominal pain or discomfort relieved by defecation(typical of IBS) and they should be mutually exclusive. However,many gastroenterologists have serious doubts as regards a clear separation. Both IBS-C and FC,often associated with many other functional digestive and non digestive disorders,are responsible for a low quality of life. The impact of the media on patients' perception of these topics is sometimes disruptive,often suggesting a distorted view of pathophysiology,diagnosis and therapy. These messages frequently overlap with previous subjective opinions and are further processed on the basis of the different culture and the previous experience of the constipated patients,often producing odd,useless or even dangerous behaviors. The aim of this review was to analyze the most common patients' beliefs about IBS-C and CC,helping physicians to understand where they should focus their attention when communicating with patients,detecting false opinions and misconceptions and correcting them on the basis of scientific evidence.展开更多
BACKGROUND Pancreatic cystic lesions(PCLs)are considered a precursor of pancreatic cancer.Needle-based confocal endomicroscopy(nCLE)is an imaging technique that enables visualization of the mucosal layer to a micron r...BACKGROUND Pancreatic cystic lesions(PCLs)are considered a precursor of pancreatic cancer.Needle-based confocal endomicroscopy(nCLE)is an imaging technique that enables visualization of the mucosal layer to a micron resolution.Its application has demonstrated promising results in the distinction of PCLs.This study evaluated the utility of nCLE in patients with indeterminate PCLs undergoing endoscopic ultrasound fine-needle aspiration(EUS-FNA)to distinguish mucinous from non-mucinous lesions.AIM To evaluate the accuracy of nCLE in indeterminate PCLs undergoing EUS-FNA to distinguish mucinous from non-mucinous lesions.METHODS Patients who required EUS-FNA between 2015 and 2017 were enrolled prospectively.During EUS-FNA,confocal imaging,analyses of the tumor markers carcinoembryonic antigen and amylase,and cytologic examination were conducted.All patients were followed for at least 12 mo and underwent laboratory testing and computed tomography scanning or magnetic resonance imaging.nCLE videos were independently reviewed by 6 observers to reach a final diagnosis(mucinous vs non-mucinous)based on criteria derived from previous studies;if there was disagreement>20%,a final diagnosis was discussed after consensus re-evaluation.The sensitivity,specificity,and accuracy of nCLE were calculated.Adverse events were recorded.RESULTS Fifty-nine patients were included in this study.Final diagnoses were derived from surgery in 10 patients,cytology in 13,and imaging and multidisciplinary team review in 36.Three patients were excluded from final diagnosis due to problems with nCLE acquisition.Fifty-six patients were included in the final analysis.The sensitivity,specificity,and accuracy of nCLE were 80%[95%confidence interval(CI):65-90],100%(95%CI:72-100),and 84%(95%CI:72-93),respectively.Postprocedure acute pancreatitis occurred in 5%.CONCLUSION EUS-nCLE performs better than standard EUS-FNA for the diagnosis of indeterminate PCL.展开更多
Using e^(+)e^(−)annihilation data corresponding to an integrated luminosity of 2.93 fb^(−1)taken at the center-of-mass energy√s=3.773 GeV with the BESIII detector,a joint amplitude analysis is performed on the decays...Using e^(+)e^(−)annihilation data corresponding to an integrated luminosity of 2.93 fb^(−1)taken at the center-of-mass energy√s=3.773 GeV with the BESIII detector,a joint amplitude analysis is performed on the decays D^(0)→π^(+)π^(−)π^(+)π^(−)and D^(0)→π^(+)π^(−)π^(0)π^(0)(non-η).The fit fractions of individual components are obtained,and large interferences among the dominant components of the decays D^(0)→a_(1)(1260)π,D^(0)→π(1300)π,D^(0)→ρ(770)ρ(770),and D^(0)→2(ππ)_(S)are observed in both channels.With the obtained amplitude model,the CP-even fractions of D^(0)→π^(+)π^(−)π^(+)π^(−)and D^(0)→π^(+)π^(−)π^(0)π^(0)(non-η)are determined to be(75.2±1.1_(stat).±1.5_(syst.))%and(68.9±1.5_(stat).±2.4_(syst.))%,respectively.The branching fractions of D^(0)→π^(+)π^(−)π^(+)π^(−)and D^(0)→π^(+)π^(−)π^(0)π^(0)(non-η)are measured to be(0.688±0.010_(stat.)±0.010_(syst.))%and(0.951±0.025_(stat.)±0.021_(syst.))%,respectively.The amplitude analysis provides an important model for the binning strategy in measuring the strong phase parameters of D^(0)→4πwhen used to determine the CKM angleγ(ϕ_(3))via the B^(−)→DK^(−)decay.展开更多
Using data taken at 29 center-of-mass energies between 4.16 and 4.70 GeV with the BESⅢdetector at the Beijing Electron Positron Collider corresponding to a total integrated luminosity of approximately 18.8 fb^(-1),th...Using data taken at 29 center-of-mass energies between 4.16 and 4.70 GeV with the BESⅢdetector at the Beijing Electron Positron Collider corresponding to a total integrated luminosity of approximately 18.8 fb^(-1),the process e^(+)e^(-)→pppñπ+c.c.is observed for the first time with a statistical significance of 11.5σ.The average Born cross sections in the energy ranges of(4.160,4.380)GeV,(4.400,4.600)GeV and(4.610,4.700)GeV are measured to be(21.5±5.7±1.2)fb,(46.3±10.6±2.5)fb and(59.0±9.4±3.2)fb,respectively,where the first uncertainties are statistical and the second are systematic.The line shapes of the pñ and ppπ^(-)invariant mass spectra are consistent with phase space distributions,indicating that no hexaquark or di-baryon state is observed.展开更多
During the 2016-17 and 2018-19 running periods,the BESIII experiment collected 7.5 fb of e^(+)e^(-)collision data at center-of-mass energies ranging from 4.13 to 4.44 GeV.These data samples are primarily used for the ...During the 2016-17 and 2018-19 running periods,the BESIII experiment collected 7.5 fb of e^(+)e^(-)collision data at center-of-mass energies ranging from 4.13 to 4.44 GeV.These data samples are primarily used for the study of excited charmonium and charmoniumlike states.By analyzing the di-muon process e^(+)e^(-)→(γISR=FSR)μ^(+)μ^(-),we measure the center-of-mass energies of the data samples with a precision of 0.6 MeV.Through a run-by-run study,we find that the center-of-mass energies were stable throughout most of the data-collection period.展开更多
Using(448.1±2.9)×10^(6)ψ(3686)for the weak baryonic decayψ(3686)→Λc+∑-+c.c..The analysis procedure is optimized using a blinded method.No significant signal is observed,and the upper limit on the branch...Using(448.1±2.9)×10^(6)ψ(3686)for the weak baryonic decayψ(3686)→Λc+∑-+c.c..The analysis procedure is optimized using a blinded method.No significant signal is observed,and the upper limit on the branching fraction(B)ofψ(3686)→Λc+∑-+c.c.is set as 1.4×10^(-5)at the 90%confidence level.展开更多
Using electron-positron annihilation data samples corresponding to an integrated luminosity of 4.5 fb-1,collected by the BESⅢdetector in the energy region between 4599.53 MeV and 4698.82 MeV,we report the first obser...Using electron-positron annihilation data samples corresponding to an integrated luminosity of 4.5 fb-1,collected by the BESⅢdetector in the energy region between 4599.53 MeV and 4698.82 MeV,we report the first observations of the Cabibbo-suppressed decaysΛ_(c)^(+)→nπ^(+)π^(0),Λ_(c)^(+)→nπ^(+)π^(-)π^(+),and the Cabibbo-favored decayΛ_(c)^(+)→nK^(-)π^(+)π^(+)with statistical significances of 7.9σ,7.8σ,and>10σ,respectively.The branching fractions of these decays are measured to be B(Λ_(c)^(+)→nπ^(+)π^(0))=(0.64±0.09±0.02)%,B(Λ_(c)^(+)→nπ^(+)π^(-)π^(+))=(0.45±0.07±0.03)%,and B(Λ_(c)^(+)→nK^(-)π^(+)π^(+))=(1.90±0.08±0.09)%,where the first uncertainties are statistical and the second are systematic.We find that the branching fraction of the decayΛ_(c)^(+)→nπ^(+)π^(0)is about one order of magnitude higher than that ofΛ_(c)^(+)→nπ^(+).展开更多
Using inclusive decays of J/ψ aprecise determination of the number of J/ψ events collected with the BESIII detector was performed.For the two data sets taken in 2009 and 2012,the numbers of J/ψ events were recalcul...Using inclusive decays of J/ψ aprecise determination of the number of J/ψ events collected with the BESIII detector was performed.For the two data sets taken in 2009 and 2012,the numbers of J/ψ events were recalculated to be(224.0±1.3)×10^(6) and(1088.5±4.4)×10^(6),respectively;these numbers are in good agreement with the previous measurements. For the J/ψ sample taken in 2017-2019,the number of events was determined to be(8774.0±39.4)×10^(6).The total number of J/ψ events collected with the BESIII detector was determined to be(10087±44)×10^(6),where the uncertainty is dominated by systematic effects,and the statistical uncertainty is negligible.展开更多
基金Supported in part by National Key Basic Research Program of China (2015CB856700)National Natural Science Foundation of China (NSFC) (11335008,11425524, 11625523, 11635010, 11735014, 11822506, 11935018)+18 种基金the Chinese Academy of Sciences (CAS) Large-Scale Scientific Facility Programthe CAS Center for Excellence in Particle Physics (CCEPP)Joint Large-Scale Scientific Facility Funds of the NSFC and CAS (U1532257, U1532258, U1732263)CAS Key Research Program of Frontier Science (QYZDJ-SSW-SLH003, QYZDJ-SSW-SLH040)100 Talents Program of CASCAS PIFIthe Thousand Talents Program of ChinaIN-PAC and Shanghai Key Laboratory for Particle Physics and CosmologyGerman Research Foundation DFG under Contracts NosCollaborative Research Center CRC 1044, FOR 2359Istituto Nazionale di Fisica Nucleare, ItalyKoninklijke Nederlandse Akademie van Wetenschappen (KNAW) (530-4CDP03)Ministry of Development of Turkey (DPT2006K-120470)National Science and Technology fundThe Knut and Alice Wallenberg Foundation (Sweden) (2016.0157)The Swedish Research CouncilU. S. Department of Energy (DE-FG02-05ER41374, DESC-0010118, DE-SC-0012069)University of Groningen (Ru G) and the Helmholtzzentrum fuer Schwerionenforschung Gmb H (GSI), Darmstadtthe Russian Ministry of Science and Higher Education (14.W03.31.0026).
文摘There has recently been a dramatic renewal of interest in hadron spectroscopy and charm physics. This renaissance has been driven in part by the discovery of a plethora of charmonium-like XYZ states at BESⅢ and B factories, and the observation of an intriguing proton-antiproton threshold enhancement and the possibly related X(1835) meson state at BESⅢ, as well as the threshold measurements of charm mesons and charm baryons. We present a detailed survey of the important topics in tau-charm physics and hadron physics that can be further explored at BESⅢ during the remaining operation period of BEPCⅡ. This survey will help in the optimization of the data-taking plan over the coming years, and provides physics motivation for the possible upgrade of BEPCⅡ to higher luminosity.
基金Supported by National Key Basic Research Program of China(2015CB856700)National Natural Science Foundation of China(11125525,11235011.11322544,11335008,11425524,Y61137005C)+7 种基金Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility Program,CAS Center for Excellence in Particle Physics(CCEPP),Collaborative Innovation Center for Particles and Interactions(CICPI),Joint Large-Scale Scientific Facility Funds of NSFC and CAS(11179007,U1232201,U1332201),CAS(KJCX2-YW-N29,KJCX2-YWN45),100 Talents Program of CASNational 1000 Talents Program of China,INPACShanghai Key Laboratory for Particle Physics and Cosmology,German Research Foundation DFG(Collaborative Research Center CRC-1044)Istituto Nazionale di Fisica Nucleare,Italy,Ministry of Development of Turkey(DPT2006K-120470)Russian Foundation for Basic Research(14-07-91152)Swedish Research Council,U.S.Department of Energy(DE-FG02-04ER41291,DE-FG02-05ER41374,DE-FG02-94ER40823,DESC0010118)U.S.National Science Foundation,University of Groningen(RuG)and Helniholtzzentrum fuer Schwerionenforschung GmbH(GSI),DarmstadtWCU Program of National Research Foundation of Korea(R32-2008-000-10155-0)
文摘From 2011 to 2014, the BESIII experiment collected about 5 fb^-1 data at center-of-mass energies around 4 GeV for the studies of the charmonium-like and higher excited charmonium states. By analyzing the di-muon process e+e- →yma/Fsμ^+μ^-, the center-of-mass energies of the data samples are measured with a precision of 0.8 MeV. The center-of-mass energy is found to be stable for most of the time during data taking.
基金Supported in part by National Key Basic Research Program of China(2015CB856700)National Natural Science Foundation of China(NSFC)(11625523,11635010,11735014,11822506,11835012,11935015,11935016,11935018,11961141012)+15 种基金the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility ProgramJoint Large-Scale Scientific Facility Funds of the NSFC and CAS(U 1732263,U 1832207)CAS Key Research Program of Frontier Sciences(QYZDJ-SSWSLH003,QYZDJ-SSW-SLH040)100 Talents Program of CASINPAC and Shanghai Key Laboratory for Particle Physics and CosmologyERC(758462)German Research Foundation DFG under Contracts Nos.Collaborative Research Center CRC 1044,FOR 2359Istituto Nazionale di Fisica Nucleare,ItalyMinistry of Development o f Turkey(DPT2006K-120470)National Science and Technology fundOlle Engkvist Foundation(200-0605)STFC(United Kingdom)The Knut and Alice Wallenberg Foundation(Sweden)(2016.0157)The Royal Society,UK(DH140054,DH160214)The Swedish Research CouncilU.S.Department of Energy(DEFG02-05ER41374,DE-SC-0012069)。
文摘Using a dedicated data sample taken in 2018 on the J/ψpeak,we perform a detailed study of the trigger efficiencies of the BESIII detector.The efficiencies are determined from three representative physics processes,namely Bhabha scattering,dimuon production and generic hadronic events with charged particles.The combined efficiency of all active triggers approaches 100%in most cases,with uncertainties small enough not to affect most physics analyses.
文摘The peripheral nerve injuries,representing some of the most common types of traumatic lesions affecting the nervous system,are highly invalidating for the patients besides being a huge social burden.Although peripheral nervous system owns a higher regenerative capacity than does central nervous system,mostly depending on Schwann cells intervention in injury repair,several factors determine the extent of functional outcome after healing.Based on the injury type,different therapeutic approaches have been investigated so far.Nerve grafting and Schwann cell transplantation have represented the gold standard treatment for peripheral nerve injuries,however these approaches own limitations,such as scarce donor nerve availability and donor site morbidity.Cell based therapies might provide a suitable tool for peripheral nerve regeneration,in fact,the ability of different stem cell types to differentiate towards Schwann cells in combination with the use of different scaffolds have been widely investigated in animal models of peripheral nerve injuries in the last decade.Dental pulp is a promising cell source for regenerative medicine,because of the ease of isolation procedures,stem cell proliferation and multipotency abilities,which are due to the embryological origin from neural crest.In this article we review the literature concerning the application of tooth derived stem cell populations combined with different conduits to peripheral nerve injuries animal models,highlighting their regenerative contribution exerted through either glial differentiation and neuroprotective/neurotrophic effects on the host tissue.
文摘Fecal calprotectin(FC) has emerged as one of the most useful tools for clinical management of inflammatory bowel diseases(IBD). Many different methods of assessment have been developed and different cutoffs have been suggested for different clinical settings. We carried out a comprehensive literature review of the most relevant FC-related topics: the role of FC in discriminating between IBD and irritable bowel syndrome(IBS) and its use in managing IBD patients In patients with intestinal symptoms, due to the high negative predictive value a normal FC level reliably rules out active IBD. In IBD patients a correlation with both mucosal healing and histology was found, and there is increasing evidence that FC assessment can be helpful in monitoring disease activity and response to therapy as well as in predicting relapse, post-operative recurrence or pouchitis. Recently, its use in the context of a treat-to-target approach led to a better outcome than clinically-based therapy adjustment in patients with early Crohn's disease. In conclusion, FC measurement represents a cheap, safe and reliable test, easy to perform and with a good reproducibility. The main concerns are still related to the choice of the optimal cut-off, both for differentiating IBD from IBS, and for the management of IBD patients.
文摘Gastroesophageal reflux disease(GERD) is a common disorder of the gastrointestinal tract. In the last few decades, new technologies have evolved and have been applied to the functional study of the esophagus, allowing for the improvement of our knowledge of the pathophysiology of GERD. High-resolution manometry(HRM) permits greater understanding of the function of the esophagogastric junction and the risks associated with hiatal hernia. Moreover, HRM has been found to be more reproducible and sensitive than conventional water-perfused manometry to detect the presence of transient lower esophageal sphincter relaxation. Esophageal 24-h p H-metry with or without combined impedance is usually performed in patients with negative endoscopy and reflux symptoms who have a poor response to anti-reflux medical therapy to assess esophageal acid exposure and symptom-reflux correlations. In particular, esophageal 24-h impedance and p H monitoring can detect acid and non-acid reflux events. Endo FLIP is a recent technique poorly applied in clinical practice, although it provides a large amount of information about the esophagogastric junction. In the coming years, laryngopharyngeal symptoms could be evaluated with up and coming non-invasive or minimally invasive techniques, such as pepsin detection in saliva or pharyngeal p H-metry. Future studies are required of these techniques to evaluate their diagnostic accuracy and usefulness, although the available data are promising.
文摘 The small bowel has long been considered a black box for endoscopists because of its long length and the presence of multiple complex loop. Most of the small bowel is inaccessible by traditional endoscopic means. In addition, radiographic studies have significant limitations with regard to diagnostic yield, and surgery is an invasive alternative. This limitation was overcome through the development of balloon enteroscopy that becomes established throughout the world for diagnostic and therapeutic examinations of the small bowel. The single-balloon enteroscope (SBE) system (Olympus, Tokyo, Japan) was introduced into the commercial market in 2007. Several study demonstrated its efficacy and safety. Early reports on the use of singleballoon enteroscopy have suggested a high diagnostic yield and similar therapeutic potential to that of the double-balloon endoscope. SBE is viable technique for in the management of small bowel disease. Technically, it is easy to perform, may be efficient, and in the literature data available, seems to provide high diagnostic and therapeutic yield.
文摘In the last decades many advances have been achieved in endoscopy, in the diagnosis and therapy of cholangiocarcinoma, however blood test, magnetic resonance imaging, computed tomography scan may fail to detect neoplastic disease at early stage, thus the diagnosis of cholangiocarcinoma is achieved usually at unresectable stage. In the last decades the role of endoscopy has moved from a diagnostic role to an invaluable therapeutic tool for patients affected by malignant bile duct obstruction. One of the major issues for cholangiocarcinoma is bile ducts occlusion, leading to jaundice, cholangitis and hepatic failure. Currently, endoscopy has a key role in the work up of cholangiocarcinoma, both in patients amenable to surgical intervention as well as in those unfit for surgery or not amenable to immediate surgical curative resection owing to locally advanced or advanced disease, with palliative intention. Endoscopy allows successful biliary drainage and stenting in more than 90% of patients with malignant bile duct obstruction, and allows rapid reduction of jaundice decreasing the risk of biliary sepsis. When biliary drainage and stenting cannot be achieved with endoscopy alone, endoscopic ultrasound-guided biliary drainage represents an effective alternative method affording successful biliary drainage in more than 80% of cases. The purpose of this review is to focus on the currently available endoscopic management options in patients with cholangiocarcinoma.
基金Supported in part by the National Key R&D Program of China(2020YFA0406400,2020YFA0406300,2023YFA1606000)the National Natural Science Foundation of China(123B2077,12035009,11635010,11735014,11875054,11935015,11935016,11935018,11961141012,12025502,12035013,12061131003,12192260,12192261,12192262,12192263,12192264,12192265,12221005,12225509,12235017,12361141819)+8 种基金the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility Program,the CAS Center for Excellence in Particle Physics(CCEPP),the Joint Large-Scale Scientific Facility Funds of the NSFC and CAS(U2032104,U1832207)the Excellent Youth Foundation of Henan Scientific Commitee(242300421044)100 Talents Program of CASthe Institute of Nuclear and Particle Physics(INPAC)and Shanghai Key Laboratory for Particle Physics and Cosmology,German Research Foundation DFG(455635585,FOR5327,GRK 2149)Istituto Nazionale di Fisica Nucleare,Italy,Ministry of Development of Turkey(DPT2006K-120470)National Research Foundation of Korea(NRF-2022R1A2C1092335)National Science and Technology fund of Mongolia,National Science Research and Innovation Fund(NSRF)via the Program Management Unit for Human Resources&Institutional Development,Research and Innovation of Thailand(B16F640076)Polish National Science Centre(2019/35/O/ST2/02907),the Swedish Research CouncilU.S.Department of Energy(DE-FG02-05ER41374)。
文摘We present a measurement of the integrated luminosity of e^(+)e^(-)collision data collected by the BESIII detector at the BEPCII collider at a center-of-mass energy of Ecm=3.773 GeV.The integrated luminosities of the datasets taken from December 2021 to June 2022,from November 2022 to June 2023,and from October 2023 to February 2024 were determined to be 4.995±0.019 fb^(-1),8.157±0.031 fb^(-1),and 4.191±0.016 fb^(-1),respectively,by analyzing large angle Bhabha scattering events.The uncertainties are dominated by systematic effects,and the statistical uncertainties are negligible.Our results provide essential input for future analyses and precision measurements.
基金supported in part by National Key R&D Program of China under Contracts Nos.2020YFA0406300,2020YFA0406400National Natural Science Foundation of China(NSFC)under Contracts Nos.12150004,11635010,11735014,11835012,11935015,11935016,11935018,11961141012,12025502,12035009,12035013,12061131003,12192260,12192261,12192262,12192263,12192264,12192265,12221005,12225509,12235017+17 种基金the Program of Science and Technology Development Plan of Jilin Province of China under Contract Nos.20210508047RQ and 20230101021JCthe Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility Programthe CAS Center for Excellence in Particle Physics(CCEPP)Joint Large-Scale Scientific Facility Funds of the NSFC and CAS under Contract No.U1832207CAS Key Research Program of Frontier Sciences under Contracts Nos.QYZDJ-SSW-SLH003,QYZDJ-SSW-SLH040100 Talents Program of CASThe Institute of Nuclear and Particle Physics(INPAC)Shanghai Key Laboratory for Particle Physics and CosmologyEuropean Union's Horizon 2020 research and innovation programme under Marie Sklodowska-Curie grant agreement under Contract No.894790German Research Foundation DFG under Contracts Nos.455635585,Collaborative Research Center CRC 1044,FOR5327,GRK 2149Istituto Nazionale di Fisica Nucleare,ItalyMinistry of Development of Turkey under Contract No.DPT2006K-120470National Research Foundation of Korea under Contract No.NRF-2022R1A2C1092335National Science and Technology fund of MongoliaNational Science Research and Innovation Fund(NSRF)via the Program Management Unit for Human Resources&Institutional Development,Research and Innovation of Thailand under Contract No.B16F640076Polish National Science Centre under Contract No.2019/35/O/ST2/02907The Swedish Research CouncilU.S.Department of Energy under Contract No.DE-FG02-05ER41374。
文摘The number ofψ(3686)events collected by the BESⅢdetector during the 2021 run period is determined to be(2259.3±11.1)×10~6 by counting inclusiveψ(3686)hadronic events.The uncertainty is systematic and the statistical uncertainty is negligible.Meanwhile,the numbers ofψ(3686)events collected during the 2009 and 2012run periods are updated to be(107.7±0.6)×10~6 and(345.4±2.6)×10~6,respectively.Both numbers are consistent with the previous measurements within one standard deviation.The total number ofψ(3686)events in the three data samples is(2712.4±14.3)×10~6.
文摘AIM:To assess linear endoscopic ultrasound (L-EUS) and magnetic resonance imaging (MRI) in biliary tract dilation and suspect small ampullary tumor.METHODS:L-EUS and MRI data were compared in 24 patients with small ampullary tumors;all with subsequent histological confirmation.Data were collected prospectively and the accuracy of detection,histological characterization and N staging were assessed retrospectivelyusing the results of surgical or endoscopic treatment as a benchmark.RESULTS:A suspicion of ampullary tumor was present in 75% of MRI and all L-EUS examinations,with 80% agreement between EUS and histological findings at endoscopy.However,L-EUS and histological TN staging at surgery showed moderate agreement (κ=0.54).CONCLUSION:L-EUS could be a useful adjunct as a diagnostic tool in the evaluation of patients with sus-pected ampullary tumors.
文摘This editorial is a commentary on the case report by Furuya et al focusing on the challenging diagnosis of early pancreatic adenocarcinoma and new tools for an earlier diagnosis.Currently,pancreatic cancer still has a poor prognosis,mainly due to late diagnosis in an advanced stage.Two main precancerous routes have been identified as pathways to pancreatic adenocarcinoma:The first encompasses a large group of mucinous cystic lesions:intraductal papillary mucinous neoplasm and mucinous cystic neoplasm,and the second is pancreatic intraepithelial neoplasia.In the last decade the focus of research has been to identify high-risk patients,using advanced imaging techniques(magnetic resonance cholangiopancreatography or endoscopic ultrasonography)which could be helpful in finding“indirect signs”of early stage pancreatic lesions.Nevertheless,the survival rate still remains poor,and alternative screening methods are under investigation.Endoscopic retrograde cholangiopancreatography followed by serial pancreatic juice aspiration cytology could be a promising tool for identifying precursor lesions such as intraductal papillary mucinous neoplasm,but confirming data are still needed to validate its role.Probably a combination of cross-sectional imaging,endoscopic techniques(old and new ones)and genetic and biological biomarkers also in pancreatic juice)could be the best solution to reach an early diagnosis.Biomarkers could help to predict and follow the progression of early pancreatic lesions.However,further studies are needed to validate their diagnostic reliability and to establish diagnostic algorithms to improve prognosis and survival in patients with pancreatic cancer.
文摘Irritable bowel syndrome(IBS) and functional constipation(FC) are the most common functional gastrointestinal disorders. According to the Rome ⅢCriteria these two disorders should be theoretically separated mainly by the presence of abdominal pain or discomfort relieved by defecation(typical of IBS) and they should be mutually exclusive. However,many gastroenterologists have serious doubts as regards a clear separation. Both IBS-C and FC,often associated with many other functional digestive and non digestive disorders,are responsible for a low quality of life. The impact of the media on patients' perception of these topics is sometimes disruptive,often suggesting a distorted view of pathophysiology,diagnosis and therapy. These messages frequently overlap with previous subjective opinions and are further processed on the basis of the different culture and the previous experience of the constipated patients,often producing odd,useless or even dangerous behaviors. The aim of this review was to analyze the most common patients' beliefs about IBS-C and CC,helping physicians to understand where they should focus their attention when communicating with patients,detecting false opinions and misconceptions and correcting them on the basis of scientific evidence.
文摘BACKGROUND Pancreatic cystic lesions(PCLs)are considered a precursor of pancreatic cancer.Needle-based confocal endomicroscopy(nCLE)is an imaging technique that enables visualization of the mucosal layer to a micron resolution.Its application has demonstrated promising results in the distinction of PCLs.This study evaluated the utility of nCLE in patients with indeterminate PCLs undergoing endoscopic ultrasound fine-needle aspiration(EUS-FNA)to distinguish mucinous from non-mucinous lesions.AIM To evaluate the accuracy of nCLE in indeterminate PCLs undergoing EUS-FNA to distinguish mucinous from non-mucinous lesions.METHODS Patients who required EUS-FNA between 2015 and 2017 were enrolled prospectively.During EUS-FNA,confocal imaging,analyses of the tumor markers carcinoembryonic antigen and amylase,and cytologic examination were conducted.All patients were followed for at least 12 mo and underwent laboratory testing and computed tomography scanning or magnetic resonance imaging.nCLE videos were independently reviewed by 6 observers to reach a final diagnosis(mucinous vs non-mucinous)based on criteria derived from previous studies;if there was disagreement>20%,a final diagnosis was discussed after consensus re-evaluation.The sensitivity,specificity,and accuracy of nCLE were calculated.Adverse events were recorded.RESULTS Fifty-nine patients were included in this study.Final diagnoses were derived from surgery in 10 patients,cytology in 13,and imaging and multidisciplinary team review in 36.Three patients were excluded from final diagnosis due to problems with nCLE acquisition.Fifty-six patients were included in the final analysis.The sensitivity,specificity,and accuracy of nCLE were 80%[95%confidence interval(CI):65-90],100%(95%CI:72-100),and 84%(95%CI:72-93),respectively.Postprocedure acute pancreatitis occurred in 5%.CONCLUSION EUS-nCLE performs better than standard EUS-FNA for the diagnosis of indeterminate PCL.
基金Supported in part by the National Key R&D Program of China(2020YFA0406300,2020YFA0406400)the National Natural Science Foundation of China(NSFC)(11625523,11635010,11735014,11835012,11935015,11935016,11935018,11961141012,12025502,12035009,12035013,12061131003,12105276,12122509,12192260,12192261,12192262,12192263,12192264,12192265,12221005,12225509,12235017)+15 种基金the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility Programthe CAS Center for Excellence in Particle Physics(CCEPP)Joint Large-Scale Scientific Facility Funds of the NSFC and CAS(U1732263,U1832103,U1832207,U2032111)CAS Key Research Program of Frontier Sciences(QYZDJ-SSW-SLH003,QYZDJ-SSW-SLH040)100 Talents Program of CASThe Institute of Nuclear and Particle Physics(INPAC)and Shanghai Key Laboratory for Particle Physics and CosmologyEuropean Union's Horizon 2020 research and innovation programme under Marie Sklodowska-Curie grant agreement(894790)German Research Foundation DFG(455635585),Collaborative Research Center CRC 1044,FOR5327,GRK 2149Istituto Nazionale di Fisica Nucleare,ItalyMinistry of Development of Turkey(DPT2006K-120470)National Research Foundation of Korea(NRF-2022R1A2C1092335)National Science and Technology fund of MongoliaNational Science Research and Innovation Fund(NSRF)via the Program Management Unit for Human Resources&Institutional Development,Research and Innovation of Thailand(B16F640076)Polish National Science Centre(2019/35/O/ST2/02907)The Swedish Research CouncilU.S.Department of Energy(DE-FG02-05ER41374)。
文摘Using e^(+)e^(−)annihilation data corresponding to an integrated luminosity of 2.93 fb^(−1)taken at the center-of-mass energy√s=3.773 GeV with the BESIII detector,a joint amplitude analysis is performed on the decays D^(0)→π^(+)π^(−)π^(+)π^(−)and D^(0)→π^(+)π^(−)π^(0)π^(0)(non-η).The fit fractions of individual components are obtained,and large interferences among the dominant components of the decays D^(0)→a_(1)(1260)π,D^(0)→π(1300)π,D^(0)→ρ(770)ρ(770),and D^(0)→2(ππ)_(S)are observed in both channels.With the obtained amplitude model,the CP-even fractions of D^(0)→π^(+)π^(−)π^(+)π^(−)and D^(0)→π^(+)π^(−)π^(0)π^(0)(non-η)are determined to be(75.2±1.1_(stat).±1.5_(syst.))%and(68.9±1.5_(stat).±2.4_(syst.))%,respectively.The branching fractions of D^(0)→π^(+)π^(−)π^(+)π^(−)and D^(0)→π^(+)π^(−)π^(0)π^(0)(non-η)are measured to be(0.688±0.010_(stat.)±0.010_(syst.))%and(0.951±0.025_(stat.)±0.021_(syst.))%,respectively.The amplitude analysis provides an important model for the binning strategy in measuring the strong phase parameters of D^(0)→4πwhen used to determine the CKM angleγ(ϕ_(3))via the B^(−)→DK^(−)decay.
基金Supported in part by National Key R&D Program of China under Contracts Nos.Supported in part by National Key R&D Program of China(2020YFA0406300,2020YFA0406400)National Natural Science Foundation of China(NSFC)(11975118,11625523,11635010,11735014,11822506,11835012,11935015,11935016,11935018,11961141012,12022510,12025502,12035009,12035013,12061131003,12075252,12192260,12192261,12192262,12192263,12192264,12192265)+19 种基金the Natural Science Foundation of Hunan Province of China(2019JJ30019)the Science and Technology Innovation Program of Hunan Province(2020RC3054)the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility ProgramJoint Large-Scale Scientific Facility Funds of the NSFC and CAS(U1732263,U1832207)CAS Key Research Program of Frontier Sciences(QYZDJ-SSW-SLH040)100 Talents Program of CASINPAC and Shanghai Key Laboratory for Particle Physics and CosmologyERC(758462)European Union Horizon 2020 research and innovation programme under Contract No.Marie Sklodowska-Curie grant agreement(894790)German Research Foundation DFG(43159800)Collaborative Research Center CRC 1044,FOR 2359,GRK 2149Istituto Nazionale di Fisica Nucleare,ItalyMinistry of Development of Turkey(DPT2006K-120470)National Science and Technology fundOlle Engkvist Foundation(200-0605)STFC(United Kingdom)The Knut and Alice Wallenberg Foundation(Sweden)(2016.0157)The Royal Society,UK(DH140054,DH160214)The Swedish Research CouncilU.S.Department of Energy(DE-FG02-05ER41374,DE-SC-0012069)。
文摘Using data taken at 29 center-of-mass energies between 4.16 and 4.70 GeV with the BESⅢdetector at the Beijing Electron Positron Collider corresponding to a total integrated luminosity of approximately 18.8 fb^(-1),the process e^(+)e^(-)→pppñπ+c.c.is observed for the first time with a statistical significance of 11.5σ.The average Born cross sections in the energy ranges of(4.160,4.380)GeV,(4.400,4.600)GeV and(4.610,4.700)GeV are measured to be(21.5±5.7±1.2)fb,(46.3±10.6±2.5)fb and(59.0±9.4±3.2)fb,respectively,where the first uncertainties are statistical and the second are systematic.The line shapes of the pñ and ppπ^(-)invariant mass spectra are consistent with phase space distributions,indicating that no hexaquark or di-baryon state is observed.
基金Supported in part by National Key Research and Development Program of China(2020YFA0406300,2020YFA0406400)National Natural Science Foundation of China(NSFC)(11625523,11635010,11735014,11822506,11835012,11935015,11935016,11935018,11961141012)+12 种基金the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility ProgramJoint Large-Scale Scientific Facility Funds of the NSFC and CAS(U1732263,U1832207)CAS Key Research Program of Frontier Sciences(QYZDJ-SSW-SLH003,QYZDJ-SSW-SLH040)100 Talents Program of CAS,INPAC and Shanghai Key Laboratory for Particle Physics and Cosmology,ERC(758462)European Union Horizon 2020 research and innovation programme(Marie Sklodowska-Curie grant agreement No 894790)German Research Foundation DFG(443159800)Collaborative Research Center CRC 1044,FOR 2359,FOR 2359,GRK 214Istituto Nazionale di Fisica Nucleare,Italy,Ministry of Development of Turkey(DPT2006K-120470)National Science and Technology fund,Olle Engkvist Foundation(200-0605)STFC(United Kingdom)The Knut and Alice Wallenberg Foundation(Sweden)(2016.0157)The Royal Society,UK(DH140054,DH160214)The Swedish Research Council,U.S.Department of Energy(DE-FG02-05ER41374,DE-SC-0012069)。
文摘During the 2016-17 and 2018-19 running periods,the BESIII experiment collected 7.5 fb of e^(+)e^(-)collision data at center-of-mass energies ranging from 4.13 to 4.44 GeV.These data samples are primarily used for the study of excited charmonium and charmoniumlike states.By analyzing the di-muon process e^(+)e^(-)→(γISR=FSR)μ^(+)μ^(-),we measure the center-of-mass energies of the data samples with a precision of 0.6 MeV.Through a run-by-run study,we find that the center-of-mass energies were stable throughout most of the data-collection period.
基金supported in part by National Key Research and Development Program of China(2020YFA0406400,2020YFA0406300)National Natural Science Foundation of China(NSFC,11975118,11635010,11735014,11835012,11935015,11935016,11935018,11961141012,12022510,12025502,12035009,12035013,12192260,12192261,12192262,12192263,12192264,12192265,12061131003)+18 种基金the Natural Science Foundation of Hunan Province of China(2019JJ30019)the Science and Technology Innovation Program of Hunan Province(2020RC3054)the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility ProgramJoint Large-Scale Scientific Facility Funds of the NSFC and CAS(U1832207)CAS Key Research Program of Frontier Sciences(QYZDJ-SSW-SLH040)100 Talents Program of CASThe Institute of Nuclear and Particle Physics(INPAC)and Shanghai Key Laboratory for Particle Physics and Cosmology,ERC(758462)European Union’s Horizon 2020 research and innovation programme under Marie Sklodowska-Curie grant agreement(894790)German Research Foundation DFG(443159800)Collaborative Research Center CRC 1044,GRK 2149Istituto Nazionale di Fisica Nucleare,ItalyMinistry of Development of Turkey(DPT2006K-120470)National Science and Technology fundNational Science Research and Innovation Fund(NSRF)via the Program Management Unit for Human Resources and Institutional Development,Research and Innovation(B16F640076)STFC(United Kingdom)Suranaree University of Technology(SUT),Thailand Science Research and Innovation(TSRI),and National Science Research and Innovation Fund(NSRF,160355)The Royal Society,UK(DH140054,DH160214)The Swedish Research CouncilU.S.Department of Energy(DE-FG02-05ER41374)。
文摘Using(448.1±2.9)×10^(6)ψ(3686)for the weak baryonic decayψ(3686)→Λc+∑-+c.c..The analysis procedure is optimized using a blinded method.No significant signal is observed,and the upper limit on the branching fraction(B)ofψ(3686)→Λc+∑-+c.c.is set as 1.4×10^(-5)at the 90%confidence level.
基金Supported in part by National Key R&D Program of China(2020YFA0406400,2020YFA0406300)National Natural Science Foundation of China(NSFC)(11635010,11735014,11805086,11835012,11935015,11935016,11935018,11975011,11961141012,12022510,12025502,12035009,12035013,12192260,12192261,12192262,12192263,12192264,12192265)+20 种基金the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility ProgramJoint Large-Scale Scientific Facility Funds of the NSFC and CAS(U1832207)the CAS Center for Excellence in Particle Physics(CCEPP)100 Talents Program of CASFundamental Research Funds for the Central Universities,Lanzhou University,University of Chinese Academy of SciencesThe Institute of Nuclear and Particle Physics(INPAC)Shanghai Key Laboratory for Particle Physics and CosmologyERC(758462)German Research Foundation DFG(443159800)Collaborative Research Center CRC 1044,GRK 2149Istituto Nazionale di Fisica Nucleare,ItalyMinistry of Development of Turkey(DPT2006K-120470)National Science and Technology fundNational Science Research and Innovation Fund(NSRF)via the Program Management Unit for Human Resources&Institutional Development,Research and Innovation(B16F640076STFC)(United Kingdom)Suranaree University of Technology(SUT)Thailand Science Research and Innovation(TSRI)National Science Research and Innovation Fund(NSRF)(160355)The Royal Society,UK(DH140054,DH160214)The Swedish Research CouncilU.S.Department of Energy(DEFG02-05ER41374)。
文摘Using electron-positron annihilation data samples corresponding to an integrated luminosity of 4.5 fb-1,collected by the BESⅢdetector in the energy region between 4599.53 MeV and 4698.82 MeV,we report the first observations of the Cabibbo-suppressed decaysΛ_(c)^(+)→nπ^(+)π^(0),Λ_(c)^(+)→nπ^(+)π^(-)π^(+),and the Cabibbo-favored decayΛ_(c)^(+)→nK^(-)π^(+)π^(+)with statistical significances of 7.9σ,7.8σ,and>10σ,respectively.The branching fractions of these decays are measured to be B(Λ_(c)^(+)→nπ^(+)π^(0))=(0.64±0.09±0.02)%,B(Λ_(c)^(+)→nπ^(+)π^(-)π^(+))=(0.45±0.07±0.03)%,and B(Λ_(c)^(+)→nK^(-)π^(+)π^(+))=(1.90±0.08±0.09)%,where the first uncertainties are statistical and the second are systematic.We find that the branching fraction of the decayΛ_(c)^(+)→nπ^(+)π^(0)is about one order of magnitude higher than that ofΛ_(c)^(+)→nπ^(+).
基金Supported in part by National Key R&D Program of China(2020YFA0406300, 2020YFA0406400)National Natural Science Foundation of China(NSFC)(11625523, 11635010, 11735014, 11822506, 11835012, 11935015, 11935016, 11935018, 11961141012, 12022510, 12025502, 12035009, 12035013,12061131003,12075252)+16 种基金the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility ProgramJoint Large-Scale Scientific Facility Funds of the NSFC and CAS(U1732263, U1832207)CAS Key Research Program of Frontier Sciences(QYZDJ-SSW-SLH040)100 Talents Program of CASINPAC and Shanghai Key Laboratory for Particle Physics and CosmologyERC(758462)European Union Horizon 2020 research and innovation programme Marie Sklodowska-Curie grant agreement(894790)German Research Foundation DFG(443159800), Collaborative Research Center CRC 1044, FOR 2359, GRK 214Istituto Nazionale di Fisica Nucleare, ItalyMinistry of Development of Turkey under Contract No. DPT2006K-120470National Science and Technology fundOlle Engkvist Foundation(200-0605)STFC(United Kingdom)The Knut and Alice Wallenberg Foundation(Sweden)(2016.0157)The Royal Society, UK(DH140054, DH160214)The Swedish Research CouncilU. S. Department of Energy(DE-FG02-05ER41374, DE-SC-0012069)
文摘Using inclusive decays of J/ψ aprecise determination of the number of J/ψ events collected with the BESIII detector was performed.For the two data sets taken in 2009 and 2012,the numbers of J/ψ events were recalculated to be(224.0±1.3)×10^(6) and(1088.5±4.4)×10^(6),respectively;these numbers are in good agreement with the previous measurements. For the J/ψ sample taken in 2017-2019,the number of events was determined to be(8774.0±39.4)×10^(6).The total number of J/ψ events collected with the BESIII detector was determined to be(10087±44)×10^(6),where the uncertainty is dominated by systematic effects,and the statistical uncertainty is negligible.