A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a be...A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a beam-splitting system for dual-route measurements,fiber bundles,a spectrometer system,and a control and acquisition system.One route is used to obtain wide-spectral-range spectra,and the other route is used to acquire high-wavelengthresolution line shapes.The spectral resolution of the wide-range spectrometers is 0.8 nm with a coverage of 800 nm(@200-1000 nm).The spectral resolution of the high-resolution spectrometer is 0.01 nm with a coverage of 6 nm(@200-660 nm).The spatial resolution of each route of D-OES is about 4 cm with 11 channels.The temporal resolution is 16 ms at maximum in the single-channel mode.Wide-range spectra(containing Balmer series and a Fulcher band)and highly resolved Ha line shapes are obtained by D-OES in the hydrogen glow discharge in the lab.D-OES measurements are carried out in the high-density deuterium experiments of HL-2A.The electron density n_(e)and deuterium temperature T_(D) in the X-point multifaceted asymmetric radiation from the edge(MARFE)region are derived simultaneously by fitting the measured D_(a) shape.The density n_(e)is observed to increase from~8.7×10^(18)m^(-3)to~7.8×10^(19)m^(-3),and the temperature T_(D)drops from~14.4 eV to~2.3 eV after the onset of MARFE in the discharge#38260.展开更多
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr...The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).展开更多
The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tok...The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tokamak discharges.This model was used to calculate the trajectory and penetration parameters of CT injections by applying both perpendicular and tangential injection schemes in both HL-2A and ITER tokamaks.For perpendicular injection along the tokamak's major radius direction from the outboard,CTs with the same injection parameters exhibited a 0.08 reduction in relative penetration depth when injected into HL-2A and a 0.13reduction when injected into ITER geometry when considering the vacuum magnetic field region compared with cases where this region was not considered.In addition,we proposed an optimization method for determining the CT's initial injection velocity to accurately calculate the initial injection velocity of CTs for central fueling in tokamaks.Furthermore,this paper discusses schemes for the tangential injection of CT into tokamak discharges.The optimal injection angle and CT magnetic moment direction for injection into both HL-2A and ITER were determined through numerical simulations.Finally,the kinetic energy loss occurring when the CT penetrated the vacuum magnetic field region in ITER was reduced byΔEk=975.08 J by optimizing the injection angle for the CT injected into ITER.These results provide valuable insights for optimizing injection angles in fusion experiments.Our model closely represents actual experimental scenarios and can assist the design of CT parameters.展开更多
An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended t...An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended to measure the density fluctuation in plasma edge(from R=1960 mm to R=2026 mm)with an improved spatial resolution of 3.3 mm,is a complement to the existing conventional beam emission spectroscopy(BES)diagnostic.In this article,we introduce the progress of LyBES diagnostic,including the collection optics,the monochromator,and the detector system.The reflectance of the collection mirrors is measured to be~82%at 122 nm,and the aberration geometrical radius of the collection optics is tested to be~150μm in the aimed area.The linear dispersion of the LyBES monochromator is designed to be~0.09 nm mm^(-1).The bandwidth of the detector system with the 5×10^(7)V A^(-1)preamplifier gain is measured to be~280 kHz,and the peak-to-peak noise of the detector system is tested to be~16 mV.The finalized design,components development and testing of the LyBES diagnostic have been completed at present,and an overall performance of the LyBES diagnostic is to be confirmed in the next HL-2A campaign.展开更多
This paper reports an improved time-delay estimation(TDE)technique for the derivation of turbulence structures based on gas-puff imaging data.The improved TDE technique,integrating an inverse timing search and hierarc...This paper reports an improved time-delay estimation(TDE)technique for the derivation of turbulence structures based on gas-puff imaging data.The improved TDE technique,integrating an inverse timing search and hierarchical strategy,offers superior accuracy in calculating turbulent velocity field maps and analyzing blob dynamics,which has the power to obtain the radial profiles of equilibrium poloidal velocity,blob size and its radial velocity,even the fluctuation analysis,such as geodesic acoustic modes and quasi-coherent mode,etc.This improved technique could provide important 2D information for the study of edge turbulence and blob dynamics,advancing the understanding of edge turbulence physics in fusion plasmas.展开更多
The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion...The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion of blobs quantitatively.The radial locations,amplitudes and scale sizes of blobs are obtained based on the fitted ellipse.Furthermore,based on the measurement of blob location,the radial and poloidal velocities of blobs are calculated.With the application of RMP,the edge poloidal shear flow is significantly weakened and the wave number spectrum changes from quasisymmetric to significantly up-down asymmetric.The application of RMP also causes the detected blob location to be much further into the far scrape-off layer(SOL)and increases the blob amplitude.Blob poloidal velocity in the SOL is slowed.Larger-size and longer-lifetime blobs are observed with RMP.With the application of RMP,stronger-amplitude and larger-size blobs are detected in the far SOL and they may cause a more serious erosion problem to the first wall.展开更多
This paper presents the characteristics of L-mode detachment,together with the behavior of edge turbulent transport and plasma confinement on the HL-2A tokamak.Partially detached and pronounced detached states have be...This paper presents the characteristics of L-mode detachment,together with the behavior of edge turbulent transport and plasma confinement on the HL-2A tokamak.Partially detached and pronounced detached states have been achieved in L-mode plasma.Stored energy was maintained before and after detachment.Edge turbulence and its transport have increased obviously in the partially detached state.In the pronounced detached state,redistribution of the density and temperature profiles due to detachment leads to low amplitude of electron temperature and pressure,as well as very weak edge turbulence and transport.Despite strong plasma radiation in the pronounced detached state,reduced edge turbulent transport contributes to maintaining stored energy in detached L-mode plasma in HL-2A.Different detachment states play an important role in the redistribution of density and temperature profiles,which requires further study.展开更多
In this article,the design of a Lyman-alpha-based beam emission spectroscopy(LAB)diagnostic on the HL-2A tokamak has been proposed for the first time.The purpose of this novel diagnostic is to measure density fluctuat...In this article,the design of a Lyman-alpha-based beam emission spectroscopy(LAB)diagnostic on the HL-2A tokamak has been proposed for the first time.The purpose of this novel diagnostic is to measure density fluctuations of tokamak plasma.The light-collection system of LAB,which consists of the first mirror and two groups of coaxial double-mirror telescopes,can realize a twosegmented viewing field ofρ=0–0.2 andρ=0.75–1,which is optimized to measure plasma density fluctuation,not only in the edge transport barrier region but also in the internal transport barrier region,to investigate the underlying physics of turbulence in tokamaks.Spectrometers are developed to separate out the Doppler-shifted target line(122.03 and 122.17 nm)from the background Lyman-alpha line(121.53 nm).Here,30 Core-LAB channels and 30 Edge-LAB channels are under development on the HL-2A tokamak.It has high radial spatial resolutions of about 2.7 mm and 3.3 mm for the core and edge channels,respectively.Taking the high light intensity of this Lyman-alpha line into account,temporal resolution of 200 k Hz can be ensured by broad bandwidth amplifiers.This high spatio-temporal resolution makes LAB a potential keen tool to experimentally investigate tokamak plasma physics.展开更多
Anomalous transports of dipole in alternating electric fields are investigated by means of numerical calculation of its average angular velocity(or current). Our results show that the alternating electric fields can m...Anomalous transports of dipole in alternating electric fields are investigated by means of numerical calculation of its average angular velocity(or current). Our results show that the alternating electric fields can make the dipole exhibit many interesting transport behaviors. There exist current bifurcation and multiple current reversal phenomena about frequency of the alternating electric fields in the system in the absence of constant bias force, while many platforms appear in the curve of its average angular velocity vs. the force, i.e., multiple mobility transitions phenomenon in the presence of the constant force, dependent on frequencies of the alternating electric fields. Further investigation indicates that the multiple mobility transitions are attributed to the traveling forces on the dipole. Intrinsic physical mechanism and conditions for the characteristic dynamical behaviors to occur are also discussed in detail. These findings will possess crucial significance for optimizing heating control in the alternating electric fields.展开更多
基金supported by the National MCF Energy R&D Program of China(Nos.2018YFE0301102,2022YFE03100004 and 2018YFE 0303102)National Natural Science Foundation of China(Nos.12375210 and 12305238)the Sichuan Natural Science Foundation(Nos.2022NSFSC1791,2022JDRC0014 and 2022TFQCCXTD)。
文摘A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a beam-splitting system for dual-route measurements,fiber bundles,a spectrometer system,and a control and acquisition system.One route is used to obtain wide-spectral-range spectra,and the other route is used to acquire high-wavelengthresolution line shapes.The spectral resolution of the wide-range spectrometers is 0.8 nm with a coverage of 800 nm(@200-1000 nm).The spectral resolution of the high-resolution spectrometer is 0.01 nm with a coverage of 6 nm(@200-660 nm).The spatial resolution of each route of D-OES is about 4 cm with 11 channels.The temporal resolution is 16 ms at maximum in the single-channel mode.Wide-range spectra(containing Balmer series and a Fulcher band)and highly resolved Ha line shapes are obtained by D-OES in the hydrogen glow discharge in the lab.D-OES measurements are carried out in the high-density deuterium experiments of HL-2A.The electron density n_(e)and deuterium temperature T_(D) in the X-point multifaceted asymmetric radiation from the edge(MARFE)region are derived simultaneously by fitting the measured D_(a) shape.The density n_(e)is observed to increase from~8.7×10^(18)m^(-3)to~7.8×10^(19)m^(-3),and the temperature T_(D)drops from~14.4 eV to~2.3 eV after the onset of MARFE in the discharge#38260.
基金supported by the National Key Research and Development Program of China(Nos.2019YFE03090100 and 2022YFE03100002)National Natural Science Foundation of China(No.12075241)。
文摘The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2022YFE03100004 and 2022YFE03060003)National Natural Science Foundation of China(Nos.12375226,12175227 and 11875255)the China Postdoctoral Science Foundation(No.2022M723066).
文摘The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tokamak discharges.This model was used to calculate the trajectory and penetration parameters of CT injections by applying both perpendicular and tangential injection schemes in both HL-2A and ITER tokamaks.For perpendicular injection along the tokamak's major radius direction from the outboard,CTs with the same injection parameters exhibited a 0.08 reduction in relative penetration depth when injected into HL-2A and a 0.13reduction when injected into ITER geometry when considering the vacuum magnetic field region compared with cases where this region was not considered.In addition,we proposed an optimization method for determining the CT's initial injection velocity to accurately calculate the initial injection velocity of CTs for central fueling in tokamaks.Furthermore,this paper discusses schemes for the tangential injection of CT into tokamak discharges.The optimal injection angle and CT magnetic moment direction for injection into both HL-2A and ITER were determined through numerical simulations.Finally,the kinetic energy loss occurring when the CT penetrated the vacuum magnetic field region in ITER was reduced byΔEk=975.08 J by optimizing the injection angle for the CT injected into ITER.These results provide valuable insights for optimizing injection angles in fusion experiments.Our model closely represents actual experimental scenarios and can assist the design of CT parameters.
基金supported by Sichuan Science and Technology Program(No.2022JDJQ0038)the National Key R&D Program of China(Nos.2022YFE03100002 and 2018YFE0303102)National Natural Science Foundation of China(Nos.12205087 and 12075241)。
文摘An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended to measure the density fluctuation in plasma edge(from R=1960 mm to R=2026 mm)with an improved spatial resolution of 3.3 mm,is a complement to the existing conventional beam emission spectroscopy(BES)diagnostic.In this article,we introduce the progress of LyBES diagnostic,including the collection optics,the monochromator,and the detector system.The reflectance of the collection mirrors is measured to be~82%at 122 nm,and the aberration geometrical radius of the collection optics is tested to be~150μm in the aimed area.The linear dispersion of the LyBES monochromator is designed to be~0.09 nm mm^(-1).The bandwidth of the detector system with the 5×10^(7)V A^(-1)preamplifier gain is measured to be~280 kHz,and the peak-to-peak noise of the detector system is tested to be~16 mV.The finalized design,components development and testing of the LyBES diagnostic have been completed at present,and an overall performance of the LyBES diagnostic is to be confirmed in the next HL-2A campaign.
基金partially supported by the National Key R&D Program of China(Nos.2019YFE03030002 and 2022YFE03030001)National Natural Science Foundation of China(Nos.12175186 and 12175055)the Natural Science Foundation of Sichuan Province(Nos.2022NSFSC1820 and 2023NSFSC1289)。
文摘This paper reports an improved time-delay estimation(TDE)technique for the derivation of turbulence structures based on gas-puff imaging data.The improved TDE technique,integrating an inverse timing search and hierarchical strategy,offers superior accuracy in calculating turbulent velocity field maps and analyzing blob dynamics,which has the power to obtain the radial profiles of equilibrium poloidal velocity,blob size and its radial velocity,even the fluctuation analysis,such as geodesic acoustic modes and quasi-coherent mode,etc.This improved technique could provide important 2D information for the study of edge turbulence and blob dynamics,advancing the understanding of edge turbulence physics in fusion plasmas.
基金supported by the National Key Research and Development Program of China(Nos.2022YFE03100002,2022YFE03010004 and 2019YFE03060002)National Natural Science Foundation of China(Nos.U1867222,U1967206 and 51821005)the Sichuan Natural Science Foundation(Nos.2022NSFSC1791 and 2020JDTD0030).
文摘The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion of blobs quantitatively.The radial locations,amplitudes and scale sizes of blobs are obtained based on the fitted ellipse.Furthermore,based on the measurement of blob location,the radial and poloidal velocities of blobs are calculated.With the application of RMP,the edge poloidal shear flow is significantly weakened and the wave number spectrum changes from quasisymmetric to significantly up-down asymmetric.The application of RMP also causes the detected blob location to be much further into the far scrape-off layer(SOL)and increases the blob amplitude.Blob poloidal velocity in the SOL is slowed.Larger-size and longer-lifetime blobs are observed with RMP.With the application of RMP,stronger-amplitude and larger-size blobs are detected in the far SOL and they may cause a more serious erosion problem to the first wall.
基金National Key Research and Development Program of China(Nos.2018YFE0303102,2018YFE0309103,2017YFE0300405 and 2017YFE0301203)National Natural Science Foundation of China(Nos.U1867222,11875124,11905051,11805055 and 11875020)Sichuan Youth Science and Technology Innovation Team Project(No.2020JDTD0030)。
文摘This paper presents the characteristics of L-mode detachment,together with the behavior of edge turbulent transport and plasma confinement on the HL-2A tokamak.Partially detached and pronounced detached states have been achieved in L-mode plasma.Stored energy was maintained before and after detachment.Edge turbulence and its transport have increased obviously in the partially detached state.In the pronounced detached state,redistribution of the density and temperature profiles due to detachment leads to low amplitude of electron temperature and pressure,as well as very weak edge turbulence and transport.Despite strong plasma radiation in the pronounced detached state,reduced edge turbulent transport contributes to maintaining stored energy in detached L-mode plasma in HL-2A.Different detachment states play an important role in the redistribution of density and temperature profiles,which requires further study.
基金supported by the National Key R&D Program of China(Nos.2022YFE03100002,2017YFE0301201 and 2018YFE0303102)Sichuan Science and Technology Program(Nos.2022JDJQ0038 and 2020JDTD0030)National Natural Science Foundation of China(No.12205087)。
文摘In this article,the design of a Lyman-alpha-based beam emission spectroscopy(LAB)diagnostic on the HL-2A tokamak has been proposed for the first time.The purpose of this novel diagnostic is to measure density fluctuations of tokamak plasma.The light-collection system of LAB,which consists of the first mirror and two groups of coaxial double-mirror telescopes,can realize a twosegmented viewing field ofρ=0–0.2 andρ=0.75–1,which is optimized to measure plasma density fluctuation,not only in the edge transport barrier region but also in the internal transport barrier region,to investigate the underlying physics of turbulence in tokamaks.Spectrometers are developed to separate out the Doppler-shifted target line(122.03 and 122.17 nm)from the background Lyman-alpha line(121.53 nm).Here,30 Core-LAB channels and 30 Edge-LAB channels are under development on the HL-2A tokamak.It has high radial spatial resolutions of about 2.7 mm and 3.3 mm for the core and edge channels,respectively.Taking the high light intensity of this Lyman-alpha line into account,temporal resolution of 200 k Hz can be ensured by broad bandwidth amplifiers.This high spatio-temporal resolution makes LAB a potential keen tool to experimentally investigate tokamak plasma physics.
基金supported by the Research Group of Nonequilibrium Statistics (Grant No. 14078206)Kunming University of Science and Technology, China。
文摘Anomalous transports of dipole in alternating electric fields are investigated by means of numerical calculation of its average angular velocity(or current). Our results show that the alternating electric fields can make the dipole exhibit many interesting transport behaviors. There exist current bifurcation and multiple current reversal phenomena about frequency of the alternating electric fields in the system in the absence of constant bias force, while many platforms appear in the curve of its average angular velocity vs. the force, i.e., multiple mobility transitions phenomenon in the presence of the constant force, dependent on frequencies of the alternating electric fields. Further investigation indicates that the multiple mobility transitions are attributed to the traveling forces on the dipole. Intrinsic physical mechanism and conditions for the characteristic dynamical behaviors to occur are also discussed in detail. These findings will possess crucial significance for optimizing heating control in the alternating electric fields.