From the mid-19th century to the end of the 20th century, photographic plates served as the primary detectors for astronomical observations. Astronomical photographic observations in China began in 1901, and over a ce...From the mid-19th century to the end of the 20th century, photographic plates served as the primary detectors for astronomical observations. Astronomical photographic observations in China began in 1901, and over a century, a total of approximately 30,000 astronomical photographic plates were captured. These historical plates play an irreplaceable role in conducting long-term, time-domain astronomical research. To preserve and explore these valuable original astronomical observational data, Shanghai Astronomical Observatory has organized the transportation of plates, taken during nighttime observations from various stations across the country, to the Sheshan Plate Archive for centralized preservation. For the first time, plate information statistics were calculated. On this basis, the plates were cleaned and digitally scanned, and finally digitized images were acquired for 29,314 plates. In this study, using Gaia DR2 as the reference star catalog, astrometric processing was carried out successfully on 15,696 single-exposure plates, including object extraction, stellar identification,and plate model computation. As a result, for long focal length telescopes, such as the 40 cm double-tube refractor telescope, the 1.56 m reflector telescope at Shanghai Astronomical Observatory, and the 1m reflecting telescope at Yunnan Astronomical Observatory, the astrometric accuracy obtained for their plates is approximately 0."1–0."3. The distribution of astrometric accuracy for medium and short focal length telescopes ranges from 0."3 to 1."0. The relevant data of this batch of plates, including digitized images and a stellar catalog of the plates, are archived and released by the National Astronomical Data Center. Users can access and download plate data based on keywords such as station, telescope, observation year, and observed celestial coordinates.展开更多
A four-stage cascaded variable optical attenuator(VOA)with a large attenuation range is presented.The VOA is based on a Mach–Zehnder interferometer(MZI)and fabricated in a silica-based planar lightwave circuit(PLC)pl...A four-stage cascaded variable optical attenuator(VOA)with a large attenuation range is presented.The VOA is based on a Mach–Zehnder interferometer(MZI)and fabricated in a silica-based planar lightwave circuit(PLC)platform.The thermo-optic effect is used to achieve intensity modulation.The measured maximum attenuation of the four-stage cascaded VOA is 88.38 d B.The chip is also tested in a quantum key distribution(QKD)system to generate signal and decoy states.The mean photon number after attenuation of the four-stage cascaded VOA is less than 0.1,which can meet the requirement of QKD.展开更多
Quantum key distribution(QKD)system based on passive silica planar lightwave circuit(PLC)asymmetric Mach–Zehnder interferometers(AMZI)is characterized with thermal stability,low loss and sufficient integration scalab...Quantum key distribution(QKD)system based on passive silica planar lightwave circuit(PLC)asymmetric Mach–Zehnder interferometers(AMZI)is characterized with thermal stability,low loss and sufficient integration scalability.However,waveguide stresses,both intrinsic and temperature-induced stresses,have significant impacts on the stable operation of the system.We have designed silica AMZI chips of 400 ps delay,with bend waveguides length equalized for both long and short arms to balance the stresses thereof.The temperature characteristics of the silica PLC AMZI chip are studied.The interference visibility at the single photon level is kept higher than 95%over a wide temperature range of 12℃.The delay time change is 0.321 ps within a temperature change of 40℃.The spectral shift is 0.0011 nm/0.1℃.Temperature-induced delay time and peak wavelength variations do not affect the interference visibility.The experiment results demonstrate the advantage of being tolerant to chip temperature fluctuations.展开更多
基金supported by the Shanghai Science and Technology Innovation Action Plan(grant No.21511104100)the Global Common Challenge Special Project(grant No.018GJHZ2023110GC)the China National Key Basic Research Program(grant No.2012FY120500)。
文摘From the mid-19th century to the end of the 20th century, photographic plates served as the primary detectors for astronomical observations. Astronomical photographic observations in China began in 1901, and over a century, a total of approximately 30,000 astronomical photographic plates were captured. These historical plates play an irreplaceable role in conducting long-term, time-domain astronomical research. To preserve and explore these valuable original astronomical observational data, Shanghai Astronomical Observatory has organized the transportation of plates, taken during nighttime observations from various stations across the country, to the Sheshan Plate Archive for centralized preservation. For the first time, plate information statistics were calculated. On this basis, the plates were cleaned and digitally scanned, and finally digitized images were acquired for 29,314 plates. In this study, using Gaia DR2 as the reference star catalog, astrometric processing was carried out successfully on 15,696 single-exposure plates, including object extraction, stellar identification,and plate model computation. As a result, for long focal length telescopes, such as the 40 cm double-tube refractor telescope, the 1.56 m reflector telescope at Shanghai Astronomical Observatory, and the 1m reflecting telescope at Yunnan Astronomical Observatory, the astrometric accuracy obtained for their plates is approximately 0."1–0."3. The distribution of astrometric accuracy for medium and short focal length telescopes ranges from 0."3 to 1."0. The relevant data of this batch of plates, including digitized images and a stellar catalog of the plates, are archived and released by the National Astronomical Data Center. Users can access and download plate data based on keywords such as station, telescope, observation year, and observed celestial coordinates.
基金the National Key Research and Development Program of China(Grant No.2019YFB2203504)Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDB43000000)the Natural Science Foundation of Anhui Province,China(Grant No.1908085QF274)。
文摘A four-stage cascaded variable optical attenuator(VOA)with a large attenuation range is presented.The VOA is based on a Mach–Zehnder interferometer(MZI)and fabricated in a silica-based planar lightwave circuit(PLC)platform.The thermo-optic effect is used to achieve intensity modulation.The measured maximum attenuation of the four-stage cascaded VOA is 88.38 d B.The chip is also tested in a quantum key distribution(QKD)system to generate signal and decoy states.The mean photon number after attenuation of the four-stage cascaded VOA is less than 0.1,which can meet the requirement of QKD.
基金Project supported by the National Key R&D Program of China (Grant No.2018YFA0306403)the Strategic Priority Research Program of Chinese Academy of Sciences (Grant No.XDB43000000)+1 种基金Innovation Program for Quantum Science and TechnologyComputer Interconnect Technology Alliance Funding (Grant No.20220103)。
文摘Quantum key distribution(QKD)system based on passive silica planar lightwave circuit(PLC)asymmetric Mach–Zehnder interferometers(AMZI)is characterized with thermal stability,low loss and sufficient integration scalability.However,waveguide stresses,both intrinsic and temperature-induced stresses,have significant impacts on the stable operation of the system.We have designed silica AMZI chips of 400 ps delay,with bend waveguides length equalized for both long and short arms to balance the stresses thereof.The temperature characteristics of the silica PLC AMZI chip are studied.The interference visibility at the single photon level is kept higher than 95%over a wide temperature range of 12℃.The delay time change is 0.321 ps within a temperature change of 40℃.The spectral shift is 0.0011 nm/0.1℃.Temperature-induced delay time and peak wavelength variations do not affect the interference visibility.The experiment results demonstrate the advantage of being tolerant to chip temperature fluctuations.
基金国家自然科学基金(6117212761401001)+4 种基金高等学校博士学科点专项科研基金(20113401110006)安徽省自然科学基金(1508085MF120)资助Supported by National Natural Science Foundation of China(6117212761401001)Specialized Research Fund for the Doctoral Program of Higher Education of China(20113401110006)and Anhui Provincial Natural Science Foundation(1508085MF120)