SOME NEW DATA AND FORMULAS FOR RESISTANCE FLOW IN FLUVIAL OPEN CHANNELS 被引量:2
1
作者 YANG Sheng-fa HU Jiang +2 位作者 li dan-xun WANG Xing-kui GUO Yakun 《Journal of Hydrodynamics》 SCIE EI CSCD 2011年第4期527-534,共8页
Flow resistance in fluvial open channels, especially in steep gravel-bed channels, still presents challenges to researchers and engineers. This article presents some new data from both the flume experiments and field ... Flow resistance in fluvial open channels, especially in steep gravel-bed channels, still presents challenges to researchers and engineers. This article presents some new data from both the flume experiments and field measurements. Data analysis using the divided hydraulic radius approach shows that the relative roughness plays a significant role in the bed form resistance. A new set of formulas that incorporate the relative roughness are proposed. As compared with several existing formulas, the proposed formulas can be used to better estimate the bed form resistance. 展开更多
关键词 open channel flow flow resistance relative roughness steep gravel-bed flume experiments field measurements
原文传递
BIAS ERRORS INDUCED BY CONCENTRATION GRADIENT IN SEDIMENT-LADEN FLOW MEASUREMENT WITH PTV 被引量:1
2
作者 li dan-xun liN Qiu-sheng +1 位作者 ZHONG Qiang WANG Xing-kui 《Journal of Hydrodynamics》 SCIE EI CSCD 2012年第5期668-674,共7页
Sediment-laden flow measurement with Particle Tracking Velocimetry (PTV) introduces a series of finite-sized sampling bins along the vertical of the flow. Instantaneous velocities are collected at each bin and a sig... Sediment-laden flow measurement with Particle Tracking Velocimetry (PTV) introduces a series of finite-sized sampling bins along the vertical of the flow. Instantaneous velocities are collected at each bin and a significantly large sample is established to evaluate mean and root mean square (rms) velocities of the flow. Due to the presence of concentration gradient, the established sample for the solid phase involves more data from the lower part of the sampling bin than from the upper part. The concentration effect causes bias errors in the measured mean and rms velocities when velocity varies across the bin. These bias errors are analyti- cally quantified in this study based on simplified linear velocity and concentration distributions. Typical bulk flow characteristics from sediment-laden flow measurements are used to demonstrate rough estimation of the error magnitude. Results indicate that the mean velocity is underestimated while the rms velocity is overestimated in the ensemble-averaged measurement. The extent of devia- tion is commensurate with the bin size and the rate of concentration gradient. Procedures are proposed to assist determining an appro- priate sampling bin size in certain error limits. 展开更多
关键词 bias error VELOCITY CONCENTRATION GRADIENT
原文传递
EVALUATION OF THE SHADING METHOD FOR REDUCING IMAGE BLOOMING IN THE PIV MEASUREMENT OF OPEN CHANNEL FLOWS 被引量:1
3
作者 ZHONG Qiang li dan-xun +1 位作者 CHEN Qi-gang WANG Xing-kui 《Journal of Hydrodynamics》 SCIE EI CSCD 2012年第2期184-192,共9页
The shading method is a simple but effective way of reducing image blooming in the measurement of open channel flows with the Particle Image Velocimetry (PIV).The current paper proposes a simplified analytical model... The shading method is a simple but effective way of reducing image blooming in the measurement of open channel flows with the Particle Image Velocimetry (PIV).The current paper proposes a simplified analytical model for light attenuation using this method.The model is verified against experimental data,and the influence of several parameters is illustrated numerically.The possible adverse effect due to the light attenuation is shown to be limited when the parameters in the shading method are in an adequate range,as shown by processing standard images of Case B in PIV Challenge 03.A simple criterion for setting the shade in experiment is given for controlling the errors caused by the shading technique within an acceptable range. 展开更多
关键词 Particle Image Velocimetry (PIV) BLOOMING SHADE open channel flows
原文传递
一种智能型腕带式心率检测仪的设计与实现 被引量:15
4
作者 熊强强 尹建平 +5 位作者 姚卫国 曾美琳 徐文磊 李柯 齐志艺 王宁 《国外电子测量技术》 2020年第2期88-92,共5页
为了解决现有心率检测仪抗干扰能力差以及功耗高的缺点,设计了一种智能型腕带式心率检测仪,通过将心率血氧模块佩戴在使用者的腕部来采集心率信号;将其经过调理和信号放大后,输入到硬件滤波电路中进行干扰杂波的初步过滤,并将过滤后的... 为了解决现有心率检测仪抗干扰能力差以及功耗高的缺点,设计了一种智能型腕带式心率检测仪,通过将心率血氧模块佩戴在使用者的腕部来采集心率信号;将其经过调理和信号放大后,输入到硬件滤波电路中进行干扰杂波的初步过滤,并将过滤后的心率信号传输给STM32单片机;单片机接收到该心率信号后,采用软件滤波算法进行干扰杂波的二次过滤,并将心率信号转换为心率参数实时显示在液晶屏上,同时启动WiFi模块实现与OneNet云平台的连接,将心率参数传输给事先与云平台绑定的手机终端。测试结果表明,该腕带式心率检测仪能够实时显示心率,测量误差不超过3%,不仅具有较强的抗干扰能力,而且能够便携使用,具有较高的性价比,适用于家庭或社区的医学监护,具有一定的推广价值。 展开更多
关键词 STM32单片机 心电波形 WiFi模块 onenet云平台
下载PDF
一种基于Lora无线局域网的智能型医用点滴监护系统设计与实现 被引量:10
5
作者 熊强强 尹建平 +2 位作者 曾美琳 徐文磊 李柯 《电子测量技术》 北大核心 2021年第2期10-14,共5页
针对采用ZigBee等传统无线技术的医用点滴监护系统存在数据传输距离有限、系统功耗高等诸多问题,设计了一款基于Lora技术的低功耗医用点滴监护系统。按照实现的功能不同可将整个点滴监护系统划分为3个部分,各个部分之间通过Lora无线网... 针对采用ZigBee等传统无线技术的医用点滴监护系统存在数据传输距离有限、系统功耗高等诸多问题,设计了一款基于Lora技术的低功耗医用点滴监护系统。按照实现的功能不同可将整个点滴监护系统划分为3个部分,各个部分之间通过Lora无线网络实现数据交互。其中检测端的核心器件为红外光电传感器,其将获取的点滴速度和药液余量一方面通过Lora无线网络发送给手持端,另一方面通过语音播报和液晶显示传达给病人,检测端还负责接收手持端和后台端发送来的病人信息。手持端接收检测端发送来的信息,护士根据接收的信息实时监测病人的点滴情况,手持端还负责将病人信息发送给后台端。后台端负责全方位监测病人和护士情况。实测结果表明,所设计的医用点滴监护系统具有较强的抗干扰能力,能够实现数据远距离传输,不仅功耗低,而且便于组网,具有广泛的应用前景。 展开更多
关键词 STM32单片机 Lora模块 无线传输 点滴监护 数据采集
下载PDF
一种基于onenet云平台的老人安全监控系统设计与实现 被引量:9
6
作者 熊强强 尹建平 +3 位作者 徐文磊 李柯 曾美琳 朱莹莺 《工业仪表与自动化装置》 2019年第6期45-49,111,共6页
针对独居老年人由于突发疾病或者意外摔倒等情况无法及时报警求助而导致的伤亡事故,设计了一款基于onenet云平台的老人安全监控系统。该系统保存了多种常见的求救语音信号,其语音识别模块采集住宅内的语音信号并传输给主控模块;主控模... 针对独居老年人由于突发疾病或者意外摔倒等情况无法及时报警求助而导致的伤亡事故,设计了一款基于onenet云平台的老人安全监控系统。该系统保存了多种常见的求救语音信号,其语音识别模块采集住宅内的语音信号并传输给主控模块;主控模块通过特征语音匹配算法将接收到的语音信号与系统中保存的呼救语音信号进行比对;当比对结果表明住宅内存在呼救语音时,报警模块启动并发出声音进行报警,同时WIFI模块启动,完成与onenet云平台的连接,利用该平台通知老人家属并拨打120进行求救。实测表明,该系统能够准确识别求救语音信号并进行报警求助,能够有效防止老年人无法呼救而导致的伤亡事故,具有较强的推广应用价值。 展开更多
关键词 onenet云平台 老人监护 语音识别 WIFI模块
下载PDF