Sensors based on optical resonators often have their measurement range limited by their cavity linewidth,particularly in the measurement of time-varying signals.This paper introduces a method for optical frequency shi...Sensors based on optical resonators often have their measurement range limited by their cavity linewidth,particularly in the measurement of time-varying signals.This paper introduces a method for optical frequency shift detection using multiple harmonics to expand the dynamic range of sensors based on optical resonators.The proposed method expands the measurement range of optical frequency shift beyond the cavity linewidth while maintaining measurement accuracy.The theoretical derivation of this method is carried out based on the equation of motion for an optical resonator and the recursive relationship of the Bessel function.Experimental results show that the dynamic range is expanded to 4 times greater than the conventional first harmonic method while still maintaining accuracy.Furthermore,we present an objective analysis of the correlation between the expansion factor of the method and the linewidth and free spectrum of the optical resonator.展开更多
Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,lo...Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,low integration costs,and self-locking,which shows great potential for application.However,the conventional single-channel microcavity thermal-locking method that relies solely on internal thermal balance will inevitably be disturbed by the external environment.This limitation affects the locking time and stability.Therefore,in this paper,we propose a new method for closed-loop thermal locking of a dual-channel microcavity.The thermal locking of the signal laser and the thermal regulation of the control laser are carried out respectively by synchronously drawing a dual-path tapered fiber.The theoretical model of the thermal dynamics of the dual-channel microcavity system is established,and the influence of the control-laser power on the thermal locking of the signal laser is confirmed.The deviation between the locking voltage of the signal laser and the set point value is used as a closed-loop feedback parameter to achieve long-term and highly stable mode locking of the signal laser.The results show that in the 2.63 h thermal-locking test,the locking stability is an order of magnitude higher than that of the single tapered fiber.This solution addresses the issue of thermal locking being disrupted by the external environment,and offers new possibilities for important applications such as spectroscopy and micro-optical sensor devices.展开更多
It is found that when the parity–time symmetry phenomenon is introduced into the resonant optical gyro system and it works near the exceptional point,the sensitivity can in theory be significantly amplified at low an...It is found that when the parity–time symmetry phenomenon is introduced into the resonant optical gyro system and it works near the exceptional point,the sensitivity can in theory be significantly amplified at low angular rate.However,in fact,the exceptional point is easily disturbed by external environmental variables,which means that it depends on harsh experimental environment and strong control ability,so it is difficult to move towards practical application.Here,we propose a new angular rate sensor structure based on exceptional surface,which has the advantages of high sensitivity and high robustness.The system consists of two fiber-optic ring resonators and two optical loop mirrors,and one of the resonators contains a variable ratio coupler and a variable optical attenuator.We theoretically analyze the system response,and the effects of phase and coupling ratio on the system response.Finally,compared with the conventional resonant gyro,the sensitivity of this exceptional surface angular rate sensor can be improved by about 300 times at low speed.In addition,by changing the loss coefficient in the ring resonator,we can achieve a wide range of 600 rad/s.This scheme provides a new approach for the development of ultra-high sensitivity and wide range angular rate sensors in the future.展开更多
Extensive numerical simulations and scaling analysis are performed to investigate competitive growth between the linear and nonlinear stochastic dynamic growth systems, which belong to the Edwards–Wilkinson(EW) and K...Extensive numerical simulations and scaling analysis are performed to investigate competitive growth between the linear and nonlinear stochastic dynamic growth systems, which belong to the Edwards–Wilkinson(EW) and Kardar–Parisi–Zhang(KPZ) universality classes, respectively. The linear growth systems include the EW equation and the model of random deposition with surface relaxation(RDSR), the nonlinear growth systems involve the KPZ equation and typical discrete models including ballistic deposition(BD), etching, and restricted solid on solid(RSOS). The scaling exponents are obtained in both the(1 + 1)-and(2 + 1)-dimensional competitive growth with the nonlinear growth probability p and the linear proportion 1-p. Our results show that, when p changes from 0 to 1, there exist non-trivial crossover effects from EW to KPZ universality classes based on different competitive growth rules. Furthermore, the growth rate and the porosity are also estimated within various linear and nonlinear growths of cooperation and competition.展开更多
High precision current measurement is very important for the calibration of various high-precision equipment and the measurement of other precision detection fields.A new current sensor based on diamond nitrogen-vacan...High precision current measurement is very important for the calibration of various high-precision equipment and the measurement of other precision detection fields.A new current sensor based on diamond nitrogen-vacancy(NV)color center magnetic measurement method is proposed to realize the accurate measurement of current.This new current method can greatly improve the accuracy of current measurement.Experiments show that the linearity of the current sensor based on diamond NV color center can reach up to 33 ppm,which is superior to other current sensors and solves the problem of low linearity.When the range of input current is 5-40 A,the absolute error of the calculated current is less than 51μA,and the relative error is 2.42×10^(-6) at 40 A.Combined with the research content and results of the experiment,the application of the current sensor in the field of current precision measurement is prospected.展开更多
基金supported by the National Natural Science Foundation of China(NSFC)(No.52305621)Foundation Research Project of Shanxi Province(No.202203021212156)Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement(No.201905D121001002)。
文摘Sensors based on optical resonators often have their measurement range limited by their cavity linewidth,particularly in the measurement of time-varying signals.This paper introduces a method for optical frequency shift detection using multiple harmonics to expand the dynamic range of sensors based on optical resonators.The proposed method expands the measurement range of optical frequency shift beyond the cavity linewidth while maintaining measurement accuracy.The theoretical derivation of this method is carried out based on the equation of motion for an optical resonator and the recursive relationship of the Bessel function.Experimental results show that the dynamic range is expanded to 4 times greater than the conventional first harmonic method while still maintaining accuracy.Furthermore,we present an objective analysis of the correlation between the expansion factor of the method and the linewidth and free spectrum of the optical resonator.
基金Project supported by the National Key Research and Development Program of China(Grant No.2022YFB3203400)the National Natural Science Foundation of China(Grant Nos.U21A20141,62273314,and 51821003)+1 种基金the Fundamental Research Program of Shanxi Province(Grant No.202303021223001)Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement(Grant No.201905D121001)。
文摘Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,low integration costs,and self-locking,which shows great potential for application.However,the conventional single-channel microcavity thermal-locking method that relies solely on internal thermal balance will inevitably be disturbed by the external environment.This limitation affects the locking time and stability.Therefore,in this paper,we propose a new method for closed-loop thermal locking of a dual-channel microcavity.The thermal locking of the signal laser and the thermal regulation of the control laser are carried out respectively by synchronously drawing a dual-path tapered fiber.The theoretical model of the thermal dynamics of the dual-channel microcavity system is established,and the influence of the control-laser power on the thermal locking of the signal laser is confirmed.The deviation between the locking voltage of the signal laser and the set point value is used as a closed-loop feedback parameter to achieve long-term and highly stable mode locking of the signal laser.The results show that in the 2.63 h thermal-locking test,the locking stability is an order of magnitude higher than that of the single tapered fiber.This solution addresses the issue of thermal locking being disrupted by the external environment,and offers new possibilities for important applications such as spectroscopy and micro-optical sensor devices.
基金supported in part by the National Natural Science Foundation of China (Grant Nos.62273314,U21A20141,and 51821003)Fundamental Research Program of Shanxi Province (Grant No.202303021224008)Shanxi Province Key Laboratory of Quantum Sensing and Precision Measure-ment (Grant No.201905D121001).
文摘It is found that when the parity–time symmetry phenomenon is introduced into the resonant optical gyro system and it works near the exceptional point,the sensitivity can in theory be significantly amplified at low angular rate.However,in fact,the exceptional point is easily disturbed by external environmental variables,which means that it depends on harsh experimental environment and strong control ability,so it is difficult to move towards practical application.Here,we propose a new angular rate sensor structure based on exceptional surface,which has the advantages of high sensitivity and high robustness.The system consists of two fiber-optic ring resonators and two optical loop mirrors,and one of the resonators contains a variable ratio coupler and a variable optical attenuator.We theoretically analyze the system response,and the effects of phase and coupling ratio on the system response.Finally,compared with the conventional resonant gyro,the sensitivity of this exceptional surface angular rate sensor can be improved by about 300 times at low speed.In addition,by changing the loss coefficient in the ring resonator,we can achieve a wide range of 600 rad/s.This scheme provides a new approach for the development of ultra-high sensitivity and wide range angular rate sensors in the future.
基金supported by Undergraduate Training Program for Innovation and Entrepreneurship of China University of Mining and Technology (CUMT)(Grant No. 202110290059Z)Fundamental Research Funds for the Central Universities of CUMT (Grant No. 2020ZDPYMS33)。
文摘Extensive numerical simulations and scaling analysis are performed to investigate competitive growth between the linear and nonlinear stochastic dynamic growth systems, which belong to the Edwards–Wilkinson(EW) and Kardar–Parisi–Zhang(KPZ) universality classes, respectively. The linear growth systems include the EW equation and the model of random deposition with surface relaxation(RDSR), the nonlinear growth systems involve the KPZ equation and typical discrete models including ballistic deposition(BD), etching, and restricted solid on solid(RSOS). The scaling exponents are obtained in both the(1 + 1)-and(2 + 1)-dimensional competitive growth with the nonlinear growth probability p and the linear proportion 1-p. Our results show that, when p changes from 0 to 1, there exist non-trivial crossover effects from EW to KPZ universality classes based on different competitive growth rules. Furthermore, the growth rate and the porosity are also estimated within various linear and nonlinear growths of cooperation and competition.
基金supported by the Introduction and Cultivation Plan of Young Innovative Talents in Colleges and Universities of Shandong Province, Chinathe Natural Science Foundation of Shandong Province, China (No. ZR2020ME052)+1 种基金the Natural Science Research Fund for Colleges and Universities in Anhui Province, China (No. KJ2021A0387)Independent Cultivation Program of Innovation Team of Jinan City, China (No. 2019GXRC011)。
基金Project supported in part by the National Natural Science Foundation of China(Grant Nos.51922009,51727808,62175219,62103385,and 51821003)the Key Laboratory of Shanxi Province(Grant No.201905D121001)the Shanxi‘1331 Project’Key Subjects Construction.
文摘High precision current measurement is very important for the calibration of various high-precision equipment and the measurement of other precision detection fields.A new current sensor based on diamond nitrogen-vacancy(NV)color center magnetic measurement method is proposed to realize the accurate measurement of current.This new current method can greatly improve the accuracy of current measurement.Experiments show that the linearity of the current sensor based on diamond NV color center can reach up to 33 ppm,which is superior to other current sensors and solves the problem of low linearity.When the range of input current is 5-40 A,the absolute error of the calculated current is less than 51μA,and the relative error is 2.42×10^(-6) at 40 A.Combined with the research content and results of the experiment,the application of the current sensor in the field of current precision measurement is prospected.