Background:Human infections with zoonotic coronaviruses(CoVs),including severe acute respiratory syndrome(SARS)-CoV and Middle East respiratory syndrome(MERS)-CoV,have raised great public health concern globally.Here,...Background:Human infections with zoonotic coronaviruses(CoVs),including severe acute respiratory syndrome(SARS)-CoV and Middle East respiratory syndrome(MERS)-CoV,have raised great public health concern globally.Here,we report a novel batorigin CoV causing severe and fatal pneumonia in humans.Methods:We collected clinical data and bronchoalveolar lavage(BAL)specimens from five patients with severe pneumonia from Wuhan Jinyintan Hospital,Hubei province,China.Nucleic acids of the BAL were extracted and subjected to next-generation sequencing.Virus isolation was carried out,and maximum-likelihood phylogenetic trees were constructed.Results:Five patients hospitalized from December 18 to December 29,2019 presented with fever,cough,and dyspnea accompanied by complications of acute respiratory distress syndrome.Chest radiography revealed diffuse opacities and consolidation.One of these patients died.Sequence results revealed the presence of a previously unknownβ-CoV strain in all five patients,with 99.8%to 99.9%nucleotide identities among the isolates.These isolates showed 79.0%nucleotide identity with the sequence of SARS-CoV(GenBank NC_004718)and 51.8%identity with the sequence of MERS-CoV(GenBank NC_019843).The virus is phylogenetically closest to a bat SARS-like CoV(SL-ZC45,GenBank MG772933)with 87.6%to 87.7%nucleotide identity,but is in a separate clade.Moreover,these viruses have a single intact open reading frame gene 8,as a further indicator of bat-origin CoVs.However,the amino acid sequence of the tentative receptor-binding domain resembles that of SARS-CoV,indicating that these viruses might use the same receptor.Conclusion:A novel bat-borne CoV was identified that is associated with severe and fatal respiratory disease in humans.展开更多
Back-streaming neutrons from the spallation target of the China Spallation Neutron Source(CSNS)that emit through the incoming proton channel were exploited to build a white neutron beam facility(the so-called Back-n w...Back-streaming neutrons from the spallation target of the China Spallation Neutron Source(CSNS)that emit through the incoming proton channel were exploited to build a white neutron beam facility(the so-called Back-n white neutron source),which was completed in March 2018.The Back-n neutron beam is very intense,at approximately 29107 n/cm2/s at 55 m from the target,and has a nominal proton beam with a power of 100 kW in the CSNS-I phase and a kinetic energy of 1.6 GeV and a thick tungsten target in multiple slices with modest moderation from the cooling water through the slices.In addition,the excellent energy spectrum spanning from 0.5 eV to 200 MeV,and a good time resolution related tothe time-of-flight measurements make it a typical white neutron source for nuclear data measurements;its overall performance is among that of the best white neutron sources in the world.Equipped with advanced spectrometers,detectors,and application utilities,the Back-n facility can serve wide applications,with a focus on neutron-induced cross-sectional measurements.This article presents an overview of the neutron beam characteristics,the experimental setups,and the ongoing applications at Backn.展开更多
AIM:To evaluate the efficacy and safety of paclitaxelnedaplatin combination as a front-line regimen in Chinese patients with metastatic esophageal squamous cell carcinoma(ESCC).METHODS:A two-center,open-label,single-a...AIM:To evaluate the efficacy and safety of paclitaxelnedaplatin combination as a front-line regimen in Chinese patients with metastatic esophageal squamous cell carcinoma(ESCC).METHODS:A two-center,open-label,single-arm phaseⅡstudy was designed.Thirty-nine patients were enrolled and included in the intention-to-treat analysis of efficacy and adverse events.Patients received 175mg/m2of paclitaxel over a 3 h infusion on 1 d,followed by nedaplatin 80 mg/m2in a 1 h infusion on 2 d every3 wk until the documented disease progression,unac-ceptable toxicity or patient’s refusal.RESULTS:Of the 36 patients assessable for efficacy,there were 2 patients(5.1%)with complete response and 16 patients(41.0%)with partial response,giving an overall response rate of 46.1%.The median progression-free survival and median overall survival for all patients were 7.1 mo(95%CI:4.6-9.7)and 12.4 mo(95%CI:9.5-15.3),respectively.Toxicities were moderate and manageable.Grade 3/4 toxicities included neutropenia(15.4%),nausea(10.3%),anemia(7.7%),thrombocytopenia(5.1%),vomiting(5.1%)and neutropenia fever(2.6%).CONCLUSION:The combination of paclitaxel and nedaplatin is active and well tolerated as a first-line therapy for patients with metastatic ESCC.展开更多
Bauxite residue is a highly alkaline waste containing soluble alkaline anions, which can cause environmental concerns. The optimal leaching conditions, distribution of alkaline anions, types of pivotal alkaline anions...Bauxite residue is a highly alkaline waste containing soluble alkaline anions, which can cause environmental concerns. The optimal leaching conditions, distribution of alkaline anions, types of pivotal alkaline anions and their dissolution behaviors were investigated based on the combination of single factors-orthogonal experiments and leaching stage experiment. Using a two-stage leaching, 86% of the soluble alkaline anions(CO3^2-, HCO4^-,Al(OH)4^-, OH^-) were leached with a L/S ratio of 2 mL/g, at 30 ℃, over 23 h. During the first stage of leaching, approximately 88% of alkaline anions were leached from the dissolution of free alkali(Na OH, carbonate, bicarbonate, NaAl(OH)4) with the rest originating from the dissolution of alkaline minerals(calcite, cancrinite and hydrogarnet). Supernatant alkalinity was 69.78 mmol/L with CO3^2- accounting for 75%. Furthermore, carbonate leaching was controlled by solid film diffusion using the Stumm Model with an apparent activation energy of 10.24 kJ/mol.展开更多
The ^(232)Th(n,f)cross section is very important in basic nuclear physics and applications based on the Th/U fuel cycle.Using the time-of-flight method and a multi-cell fast-fission ionization chamber,a novel measurem...The ^(232)Th(n,f)cross section is very important in basic nuclear physics and applications based on the Th/U fuel cycle.Using the time-of-flight method and a multi-cell fast-fission ionization chamber,a novel measurement of the^(232)Th(n,f)cross sec-tion relative to^(235)U in the 1–200 MeV range was performed at the China Spallation Neutron Source Back-n white neutron source(Back-n).The fission event-neutron energy spectra of^(232)Th and^(235)U fission cells were measured in the single-bunch mode.Corrected 232Th/235U fission cross-sectional ratios were obtained,and the measurement uncertainties were 2.5–3.7%for energies in the 2–20 MeV range and 3.6–6.2%for energies in the 20–200 MeV range.The^(232)Th(n,f)cross section was obtained by introducing the standard cross section of^(235)U(n,f).The results were compared with those of previous theoreti-cal calculations,measurements,and evaluations.The measured 232Th fission cross section agreed with the main evaluation results in terms of the experimental uncertainty,and 232Th fission resonances were observed in the 1–3 MeV range.The present results provide^(232)Th(n,f)cross-sectional data for the evaluation and design of Th/U cycle nuclear systems.展开更多
Background:Accurate prediction of ischemic stroke is required for deciding anticoagulation use in patients with atrial fibrillation(AF).Even though only 6%to 8%of AF patients die from stroke,about 90%are indicated for...Background:Accurate prediction of ischemic stroke is required for deciding anticoagulation use in patients with atrial fibrillation(AF).Even though only 6%to 8%of AF patients die from stroke,about 90%are indicated for anticoagulants according to the current AF management guidelines.Therefore,we aimed to develop an accurate and easy-to-use new risk model for 1-year thromboembolic events(TEs)in Chinese AF patients.Methods:From the prospective China Atrial Fibrillation Registry cohort study,we identified 6601 AF patients who were not treated with anticoagulation or ablation at baseline.We selected the most important variables by the extreme gradient boosting(XGBoost)algorithm and developed a simplified risk model for predicting 1-year TEs.The novel risk score was internally validated using bootstrapping with 1000 replicates and compared with the CHA2DS2-VA score(excluding female sex from the CHA2DS2-VASc score).Results:Up to the follow-up of 1 year,163 TEs(ischemic stroke or systemic embolism)occurred.Using the XGBoost algorithm,we selected the three most important variables(congestive heart failure or left ventricular dysfunction,age,and prior stroke,abbreviated as CAS model)to predict 1-year TE risk.We trained a multivariate Cox regression model and assigned point scores proportional to model coefficients.The CAS scheme classified 30.8%(2033/6601)of the patients as low risk for TE(CAS score=0),with a corresponding 1-year TE risk of 0.81%(95%confidence interval[CI]:0.41%–1.19%).In our cohort,the C-statistic of CAS model was 0.69(95%CI:0.65–0.73),higher than that of CHA2DS2-VA score(0.66,95%CI:0.62–0.70,Z=2.01,P=0.045).The overall net reclassification improvement from CHA2DS2-VA categories(low=0/high≥1)to CAS categories(low=0/high≥1)was 12.2%(95%CI:8.7%–15.7%).Conclusion:In Chinese AF patients,a novel and simple CAS risk model better predicted 1-year TEs than the widely-used CHA2DS2-VA risk score and identified a large proportion of patients with low risk of TEs,which could potentially improve anticoagul展开更多
Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted signifi...Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted significant attention owing to their potential for exhibiting a high neutron detection efficiency over a large neutron energy range.Good spatial and temporal resolutions are useful for neutron energy-resolved imaging.However,their practical applications still face many technical challenges.In this study,a B-MCP with 10 mol%10B was tested for its response to wide-energy neutrons from eV to MeV at the Back-n white neutron source at the China Spallation Neutron Source.The neutron detection efficiency was calibrated at 1 eV,which is approximately 300 times that of an ordinary MCP and indicates the success of 10 B doping.The factors that caused the reduction in the detection efficiency were simulated and discussed.The neutron energy spectrum obtained using B-MCP was compared with that obtained by other measurement methods,and showed very good consistency for neutron energies below tens of keV.The response is more complicated at higher neutron energy,at which point the elastic and nonelastic reactions of all nuclides of B-MCP gradually become dominant.This is beneficial for the detection of neutrons,as it compensates for the detection efficiency of B-MCP for high-energy neutrons.展开更多
The back-streaming white-neutron beamline(Back-n)of the China Spallation Neutron Source is an essential neutronresearch platform built for the study of nuclear data,neutron physics,and neutron applications.Many types ...The back-streaming white-neutron beamline(Back-n)of the China Spallation Neutron Source is an essential neutronresearch platform built for the study of nuclear data,neutron physics,and neutron applications.Many types of cross-sectional neutron-reaction measurements have been performed at Back-n since early 2018.These measurements have shown that a significant number of gamma rays can be transmitted to the experimental stations of Back-n along with the neutron beam.These gamma rays,commonly referred to as in-beam gamma rays,can induce a non-negligible experimental background in neutron-reaction measurements.Studying the characteristics of in-beam gamma rays is important for understanding the experimental background.However,measuring in-beam gamma rays is challenging because most gamma-ray detectors are sensitive to neutrons;thus,discriminating between neutron-induced signals and those from in-beam gamma rays is difficult.In this study,we propose the use of the black resonance filter method and a CeBr_(3) scintillation detector to measure the characteristics of the in-beam gamma rays of Back-n.Four types of black resonance filters,^(181)Ta,^(59)Co,^(nat)Ag,and^(nat)Cd,were used in this measurement.The time-of-flight(TOF)technique was used to select the detector signals remaining in the absorption region of the TOF spectra,which were mainly induced by in-beam gamma rays.The energy distribution and flux of the in-beam gamma rays of Back-n were determined by analyzing the deposited energy spectra of the CeBr_(3) scintillation detector and using Monte Carlo simulations.Based on the results of this study,the background contributions from in-beam gamma rays in neutron-reaction measurements at Back-n can be reasonably evaluated,which is beneficial for enhancing both the experimental methodology and data analysis.展开更多
Nondestructive and noninvasive neutron assays are essential applications of neutron techniques.Neutron resonance transmission analysis(NRTA)is a powerful nondestructive method for investigating the elemental compositi...Nondestructive and noninvasive neutron assays are essential applications of neutron techniques.Neutron resonance transmission analysis(NRTA)is a powerful nondestructive method for investigating the elemental composition of an object.The back-streaming neutron line(Back-n)is a newly built time-of-flight facility at the China Spallation Neutron Source(CSNS)that provides neutrons in the eV to 300 MeV range.A feasibility study of the NRTA method for nuclide identification was conducted at the CSNS Back-n via two test experiments.The results demonstrate that it is feasible to identify different elements and isotopes in samples using the NRTA method at Back-n.This study reveals its potential future applications.展开更多
Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron s...Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron source and detector.Consequently,the progression of NRI technology has been sluggish since its inception in the 1980s,particularly considering the limited studies analyzing the neutron energy range above keV.The white neutron source(Back-n)at the China Spallation Neutron Source(CSNS)provides favorable beam conditions for the development of the NRI technique over a wide neutron energy range from eV to MeV.Neutron-sensitive microchannel plates(MCP)have emerged as a cutting-edge tool in the field of neutron detection owing to their high temporal and spatial resolutions,high detection efficiency,and low noise.In this study,we report the development of a 10B-doped MCP detector,along with its associated electronics,data processing system,and NRI experiments at the Back-n.Individual heavy elements such as gold,silver,tungsten,and indium can be easily identified in the transmission images by their characteristic resonance peaks in the 1–100 eV energy range;the more difficult medium-weight elements such as iron,copper,and aluminum with resonance peaks in the 1–100 keV energy range can also be identified.In particular,results in the neutron energy range of dozens of keV(Aluminum)are reported here for the first time.展开更多
基金This study was supported by grants from the Chinese Academy of Medical Sciences(CAMS)Innovation Fund for Medical Sciences(No.2016-I2M-1-014)the National Major Science&Technology Project for Control and Prevention of Major Infectious Diseases in China(Nos.2017ZX10103004,2018ZX10305409,2017ZX10204401)the National Natural Science Foundation(No.81930063)
文摘Background:Human infections with zoonotic coronaviruses(CoVs),including severe acute respiratory syndrome(SARS)-CoV and Middle East respiratory syndrome(MERS)-CoV,have raised great public health concern globally.Here,we report a novel batorigin CoV causing severe and fatal pneumonia in humans.Methods:We collected clinical data and bronchoalveolar lavage(BAL)specimens from five patients with severe pneumonia from Wuhan Jinyintan Hospital,Hubei province,China.Nucleic acids of the BAL were extracted and subjected to next-generation sequencing.Virus isolation was carried out,and maximum-likelihood phylogenetic trees were constructed.Results:Five patients hospitalized from December 18 to December 29,2019 presented with fever,cough,and dyspnea accompanied by complications of acute respiratory distress syndrome.Chest radiography revealed diffuse opacities and consolidation.One of these patients died.Sequence results revealed the presence of a previously unknownβ-CoV strain in all five patients,with 99.8%to 99.9%nucleotide identities among the isolates.These isolates showed 79.0%nucleotide identity with the sequence of SARS-CoV(GenBank NC_004718)and 51.8%identity with the sequence of MERS-CoV(GenBank NC_019843).The virus is phylogenetically closest to a bat SARS-like CoV(SL-ZC45,GenBank MG772933)with 87.6%to 87.7%nucleotide identity,but is in a separate clade.Moreover,these viruses have a single intact open reading frame gene 8,as a further indicator of bat-origin CoVs.However,the amino acid sequence of the tentative receptor-binding domain resembles that of SARS-CoV,indicating that these viruses might use the same receptor.Conclusion:A novel bat-borne CoV was identified that is associated with severe and fatal respiratory disease in humans.
基金This work was jointly supported by the National Key Research and Development Program of China(No.2016YFA0401600)National Natural Science Foundation of China(Nos.11235012 and 12035017)+1 种基金the CSNS Engineering Projectthe Back-n Collaboration Consortium fund。
文摘Back-streaming neutrons from the spallation target of the China Spallation Neutron Source(CSNS)that emit through the incoming proton channel were exploited to build a white neutron beam facility(the so-called Back-n white neutron source),which was completed in March 2018.The Back-n neutron beam is very intense,at approximately 29107 n/cm2/s at 55 m from the target,and has a nominal proton beam with a power of 100 kW in the CSNS-I phase and a kinetic energy of 1.6 GeV and a thick tungsten target in multiple slices with modest moderation from the cooling water through the slices.In addition,the excellent energy spectrum spanning from 0.5 eV to 200 MeV,and a good time resolution related tothe time-of-flight measurements make it a typical white neutron source for nuclear data measurements;its overall performance is among that of the best white neutron sources in the world.Equipped with advanced spectrometers,detectors,and application utilities,the Back-n facility can serve wide applications,with a focus on neutron-induced cross-sectional measurements.This article presents an overview of the neutron beam characteristics,the experimental setups,and the ongoing applications at Backn.
基金Supported by Natural Science Foundation of Anhui Province No.070413256XMedical Research Foundation of Anhui Provincial Health Department No.2010B001 and No.13zc012
文摘AIM:To evaluate the efficacy and safety of paclitaxelnedaplatin combination as a front-line regimen in Chinese patients with metastatic esophageal squamous cell carcinoma(ESCC).METHODS:A two-center,open-label,single-arm phaseⅡstudy was designed.Thirty-nine patients were enrolled and included in the intention-to-treat analysis of efficacy and adverse events.Patients received 175mg/m2of paclitaxel over a 3 h infusion on 1 d,followed by nedaplatin 80 mg/m2in a 1 h infusion on 2 d every3 wk until the documented disease progression,unac-ceptable toxicity or patient’s refusal.RESULTS:Of the 36 patients assessable for efficacy,there were 2 patients(5.1%)with complete response and 16 patients(41.0%)with partial response,giving an overall response rate of 46.1%.The median progression-free survival and median overall survival for all patients were 7.1 mo(95%CI:4.6-9.7)and 12.4 mo(95%CI:9.5-15.3),respectively.Toxicities were moderate and manageable.Grade 3/4 toxicities included neutropenia(15.4%),nausea(10.3%),anemia(7.7%),thrombocytopenia(5.1%),vomiting(5.1%)and neutropenia fever(2.6%).CONCLUSION:The combination of paclitaxel and nedaplatin is active and well tolerated as a first-line therapy for patients with metastatic ESCC.
基金Project(41371475)supported by the National Natural Science Foundation of ChinaProject(201509048)supported by the Environmental Protection’s Special Scientific Research for Chinese Public Welfare Industry
文摘Bauxite residue is a highly alkaline waste containing soluble alkaline anions, which can cause environmental concerns. The optimal leaching conditions, distribution of alkaline anions, types of pivotal alkaline anions and their dissolution behaviors were investigated based on the combination of single factors-orthogonal experiments and leaching stage experiment. Using a two-stage leaching, 86% of the soluble alkaline anions(CO3^2-, HCO4^-,Al(OH)4^-, OH^-) were leached with a L/S ratio of 2 mL/g, at 30 ℃, over 23 h. During the first stage of leaching, approximately 88% of alkaline anions were leached from the dissolution of free alkali(Na OH, carbonate, bicarbonate, NaAl(OH)4) with the rest originating from the dissolution of alkaline minerals(calcite, cancrinite and hydrogarnet). Supernatant alkalinity was 69.78 mmol/L with CO3^2- accounting for 75%. Furthermore, carbonate leaching was controlled by solid film diffusion using the Stumm Model with an apparent activation energy of 10.24 kJ/mol.
基金supported by the National Natural Science Foundation of China(Nos.11675155,11790321,and 12075216)the National Key Research and Development Plan(No.2016YFA0401603).
文摘The ^(232)Th(n,f)cross section is very important in basic nuclear physics and applications based on the Th/U fuel cycle.Using the time-of-flight method and a multi-cell fast-fission ionization chamber,a novel measurement of the^(232)Th(n,f)cross sec-tion relative to^(235)U in the 1–200 MeV range was performed at the China Spallation Neutron Source Back-n white neutron source(Back-n).The fission event-neutron energy spectra of^(232)Th and^(235)U fission cells were measured in the single-bunch mode.Corrected 232Th/235U fission cross-sectional ratios were obtained,and the measurement uncertainties were 2.5–3.7%for energies in the 2–20 MeV range and 3.6–6.2%for energies in the 20–200 MeV range.The^(232)Th(n,f)cross section was obtained by introducing the standard cross section of^(235)U(n,f).The results were compared with those of previous theoreti-cal calculations,measurements,and evaluations.The measured 232Th fission cross section agreed with the main evaluation results in terms of the experimental uncertainty,and 232Th fission resonances were observed in the 1–3 MeV range.The present results provide^(232)Th(n,f)cross-sectional data for the evaluation and design of Th/U cycle nuclear systems.
基金supported by the National Key Research and Development Program of China(Nos.2017YFC0908803,2018YFC1312501,and 2020YFC2004803)a grant from the Beijing Municipal Commission of Science and Technology(No.D171100006817001)supported by grants from Bristol-Myers Squibb,Pfizer,Johnson&Johnson,Boehringer-Ingelheim,and Bayer.
文摘Background:Accurate prediction of ischemic stroke is required for deciding anticoagulation use in patients with atrial fibrillation(AF).Even though only 6%to 8%of AF patients die from stroke,about 90%are indicated for anticoagulants according to the current AF management guidelines.Therefore,we aimed to develop an accurate and easy-to-use new risk model for 1-year thromboembolic events(TEs)in Chinese AF patients.Methods:From the prospective China Atrial Fibrillation Registry cohort study,we identified 6601 AF patients who were not treated with anticoagulation or ablation at baseline.We selected the most important variables by the extreme gradient boosting(XGBoost)algorithm and developed a simplified risk model for predicting 1-year TEs.The novel risk score was internally validated using bootstrapping with 1000 replicates and compared with the CHA2DS2-VA score(excluding female sex from the CHA2DS2-VASc score).Results:Up to the follow-up of 1 year,163 TEs(ischemic stroke or systemic embolism)occurred.Using the XGBoost algorithm,we selected the three most important variables(congestive heart failure or left ventricular dysfunction,age,and prior stroke,abbreviated as CAS model)to predict 1-year TE risk.We trained a multivariate Cox regression model and assigned point scores proportional to model coefficients.The CAS scheme classified 30.8%(2033/6601)of the patients as low risk for TE(CAS score=0),with a corresponding 1-year TE risk of 0.81%(95%confidence interval[CI]:0.41%–1.19%).In our cohort,the C-statistic of CAS model was 0.69(95%CI:0.65–0.73),higher than that of CHA2DS2-VA score(0.66,95%CI:0.62–0.70,Z=2.01,P=0.045).The overall net reclassification improvement from CHA2DS2-VA categories(low=0/high≥1)to CAS categories(low=0/high≥1)was 12.2%(95%CI:8.7%–15.7%).Conclusion:In Chinese AF patients,a novel and simple CAS risk model better predicted 1-year TEs than the widely-used CHA2DS2-VA risk score and identified a large proportion of patients with low risk of TEs,which could potentially improve anticoagul
基金supported by the Guangdong Basic and Applied Basic Research Foundation(No.2023A1515030074)the National Natural Science Foundation of China(No.12035017)。
文摘Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted significant attention owing to their potential for exhibiting a high neutron detection efficiency over a large neutron energy range.Good spatial and temporal resolutions are useful for neutron energy-resolved imaging.However,their practical applications still face many technical challenges.In this study,a B-MCP with 10 mol%10B was tested for its response to wide-energy neutrons from eV to MeV at the Back-n white neutron source at the China Spallation Neutron Source.The neutron detection efficiency was calibrated at 1 eV,which is approximately 300 times that of an ordinary MCP and indicates the success of 10 B doping.The factors that caused the reduction in the detection efficiency were simulated and discussed.The neutron energy spectrum obtained using B-MCP was compared with that obtained by other measurement methods,and showed very good consistency for neutron energies below tens of keV.The response is more complicated at higher neutron energy,at which point the elastic and nonelastic reactions of all nuclides of B-MCP gradually become dominant.This is beneficial for the detection of neutrons,as it compensates for the detection efficiency of B-MCP for high-energy neutrons.
基金supported by the Youth Talent Program of China National Nuclear Corporationthe Continuous-Support Basic Scientific Research Project(BJ010261223282)+1 种基金the National Natural Science Foundation of China(No.11790321)the Research and development project of China National Nuclear Corporation。
文摘The back-streaming white-neutron beamline(Back-n)of the China Spallation Neutron Source is an essential neutronresearch platform built for the study of nuclear data,neutron physics,and neutron applications.Many types of cross-sectional neutron-reaction measurements have been performed at Back-n since early 2018.These measurements have shown that a significant number of gamma rays can be transmitted to the experimental stations of Back-n along with the neutron beam.These gamma rays,commonly referred to as in-beam gamma rays,can induce a non-negligible experimental background in neutron-reaction measurements.Studying the characteristics of in-beam gamma rays is important for understanding the experimental background.However,measuring in-beam gamma rays is challenging because most gamma-ray detectors are sensitive to neutrons;thus,discriminating between neutron-induced signals and those from in-beam gamma rays is difficult.In this study,we propose the use of the black resonance filter method and a CeBr_(3) scintillation detector to measure the characteristics of the in-beam gamma rays of Back-n.Four types of black resonance filters,^(181)Ta,^(59)Co,^(nat)Ag,and^(nat)Cd,were used in this measurement.The time-of-flight(TOF)technique was used to select the detector signals remaining in the absorption region of the TOF spectra,which were mainly induced by in-beam gamma rays.The energy distribution and flux of the in-beam gamma rays of Back-n were determined by analyzing the deposited energy spectra of the CeBr_(3) scintillation detector and using Monte Carlo simulations.Based on the results of this study,the background contributions from in-beam gamma rays in neutron-reaction measurements at Back-n can be reasonably evaluated,which is beneficial for enhancing both the experimental methodology and data analysis.
基金This work was supported by the National Natural Science Foundation of China(No.12035017)Youth Innovation Promotion Association CAS(No.2023014)Guangdong Basic and Applied Basic Research Foundation(Nos.2020A1515010360 and 2022B1515120032).
文摘Nondestructive and noninvasive neutron assays are essential applications of neutron techniques.Neutron resonance transmission analysis(NRTA)is a powerful nondestructive method for investigating the elemental composition of an object.The back-streaming neutron line(Back-n)is a newly built time-of-flight facility at the China Spallation Neutron Source(CSNS)that provides neutrons in the eV to 300 MeV range.A feasibility study of the NRTA method for nuclide identification was conducted at the CSNS Back-n via two test experiments.The results demonstrate that it is feasible to identify different elements and isotopes in samples using the NRTA method at Back-n.This study reveals its potential future applications.
基金supported by the National Natural Science Foundation of China(No.12035017)the Guangdong Basic and Applied Basic Research Foundation(No.2023A1515030074)。
文摘Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron source and detector.Consequently,the progression of NRI technology has been sluggish since its inception in the 1980s,particularly considering the limited studies analyzing the neutron energy range above keV.The white neutron source(Back-n)at the China Spallation Neutron Source(CSNS)provides favorable beam conditions for the development of the NRI technique over a wide neutron energy range from eV to MeV.Neutron-sensitive microchannel plates(MCP)have emerged as a cutting-edge tool in the field of neutron detection owing to their high temporal and spatial resolutions,high detection efficiency,and low noise.In this study,we report the development of a 10B-doped MCP detector,along with its associated electronics,data processing system,and NRI experiments at the Back-n.Individual heavy elements such as gold,silver,tungsten,and indium can be easily identified in the transmission images by their characteristic resonance peaks in the 1–100 eV energy range;the more difficult medium-weight elements such as iron,copper,and aluminum with resonance peaks in the 1–100 keV energy range can also be identified.In particular,results in the neutron energy range of dozens of keV(Aluminum)are reported here for the first time.