Ventilation is one of the factors contributing to energy consumption in buildings and food preservation. The solar chimney proves to be an alternative for reducing conventional energy consumption. Thus, in this study,...Ventilation is one of the factors contributing to energy consumption in buildings and food preservation. The solar chimney proves to be an alternative for reducing conventional energy consumption. Thus, in this study, the performance of a solar chimney with two active faces for thermally drawing air from a chamber for preserving agri-food products was evaluated. These performances were experimentally assessed through data measurements: temperatures and velocities within the chimney, and their analysis using Excel and MATLAB. The obtained results were compared with those from literature to verify their validity. From this study, it is found that the maximum temperature at the chimney outlet reaches 49.4˚C with an average value of 43.7˚C. Additionally, the heating evolution of the chimney air presents four (04) identical phases in pairs, reflecting the chimney’s operation throughout day. The temperature difference between the outlet and inlet of the chimney reaches a maximum of 17˚C with an average of 12.6˚C. Regarding airflow, the maximum air velocity at the chimney outlet is 0.8 m/s, and the average velocities have consistently been greater than or equal to 0.46 m/s. Thus, it can be concluded that the solar chimney is capable of providing ventilation for the preservation chamber through thermal draft.展开更多
Buildings constructed with modern materials (cement blocks, sheet metal, reinforced concrete, etc.) in the Sahelian zone often generate excessive electricity consumption and consequently very high electricity bills. T...Buildings constructed with modern materials (cement blocks, sheet metal, reinforced concrete, etc.) in the Sahelian zone often generate excessive electricity consumption and consequently very high electricity bills. This study is a contribution to the development of new building types based on the principle of bioclimatic construction. The aim is to find materials suited to the Sahelian climate and improve thermal comfort. To this end, an experimental study of the hygrothermal behavior of a bioclimatic building prototype with a domed roof is being carried out. Site meteorological data, air temperature and relative humidity of the building’s internal environment were measured for three climatic seasons in Burkina Faso. The data acquisition system consists of thermocouples, solarimeters and humidity meters, and the data are processed using Excel and Origin Pro software. The results show that, despite the high temperature values (between 36˚C and 39˚C) of the internal environment measured in the hot season, good thermal performance is achieved, in particular an average phase shift of 7.17 h and an average damping of 10.81˚C. The dome-roofed building could therefore contribute to limiting heat transmission to the building interior, improving thermal comfort all year round. Analysis of humidity profiles shows that indoor humidity varies between 66% and 80% for the September period, and between 44% and 69% for the January period. The high values of internal ambient humidity could be reduced by very good ventilation of the building. This study shows that the proposed bioclimatic building prototype with domed roof could be integrated into the Sahelian habitat.展开更多
文摘Ventilation is one of the factors contributing to energy consumption in buildings and food preservation. The solar chimney proves to be an alternative for reducing conventional energy consumption. Thus, in this study, the performance of a solar chimney with two active faces for thermally drawing air from a chamber for preserving agri-food products was evaluated. These performances were experimentally assessed through data measurements: temperatures and velocities within the chimney, and their analysis using Excel and MATLAB. The obtained results were compared with those from literature to verify their validity. From this study, it is found that the maximum temperature at the chimney outlet reaches 49.4˚C with an average value of 43.7˚C. Additionally, the heating evolution of the chimney air presents four (04) identical phases in pairs, reflecting the chimney’s operation throughout day. The temperature difference between the outlet and inlet of the chimney reaches a maximum of 17˚C with an average of 12.6˚C. Regarding airflow, the maximum air velocity at the chimney outlet is 0.8 m/s, and the average velocities have consistently been greater than or equal to 0.46 m/s. Thus, it can be concluded that the solar chimney is capable of providing ventilation for the preservation chamber through thermal draft.
文摘Buildings constructed with modern materials (cement blocks, sheet metal, reinforced concrete, etc.) in the Sahelian zone often generate excessive electricity consumption and consequently very high electricity bills. This study is a contribution to the development of new building types based on the principle of bioclimatic construction. The aim is to find materials suited to the Sahelian climate and improve thermal comfort. To this end, an experimental study of the hygrothermal behavior of a bioclimatic building prototype with a domed roof is being carried out. Site meteorological data, air temperature and relative humidity of the building’s internal environment were measured for three climatic seasons in Burkina Faso. The data acquisition system consists of thermocouples, solarimeters and humidity meters, and the data are processed using Excel and Origin Pro software. The results show that, despite the high temperature values (between 36˚C and 39˚C) of the internal environment measured in the hot season, good thermal performance is achieved, in particular an average phase shift of 7.17 h and an average damping of 10.81˚C. The dome-roofed building could therefore contribute to limiting heat transmission to the building interior, improving thermal comfort all year round. Analysis of humidity profiles shows that indoor humidity varies between 66% and 80% for the September period, and between 44% and 69% for the January period. The high values of internal ambient humidity could be reduced by very good ventilation of the building. This study shows that the proposed bioclimatic building prototype with domed roof could be integrated into the Sahelian habitat.