This present research work focuses on the valorization of pig droppings for production of biogas in mono digestion and co-digestion with proportions of cow dung from the urban commune of N’Zérékoré. It...This present research work focuses on the valorization of pig droppings for production of biogas in mono digestion and co-digestion with proportions of cow dung from the urban commune of N’Zérékoré. It was carried out in December 2020 in the Physics laboratory of the University of N’Zérékoré. The anaerobic digestion process took 25 days in an almost constant ambient temperature of 25˚C. Five digesters were loaded on 12/06/2020, two of which with 1 kg of pig dung and 1 kg of cow dung both in mono-digestion. The 3 other digesters in co-digestion with different proportions of pig manure and cow dung. The substrate in each digester is diluted in 2 liters of water, with a proportion of (1/2). The main results obtained are: 1) the evolution of the temperature and pH during digestion process, 2) the average biogas productions 0.61 liters for (D1);1.20 liter for (D2);1.65 liter for (D3);1.51 liter for (D4) and 1.31 liter for (D5). The cumulative amounts of biogas are respectively: D1 (7.95 liters), D2 (15.60 liters), D3 (21.50 liters), D4 (19.65 liters) and D5 (17.05 liters). The total cumulative production is 81.75 liters at the end of the process. The originality of this research work is that the proposed model examines the relation between the daily biogas production and the variation of temperature, pH and pressure. The combustibility test showed the biogas produced during the first week was no combustible (contains less than 50% methane). Combustion started from the biogas produced from the 15th day and it is from the 20th day that a significant amount of stable yellow/blue flame was observed. The results of this study show the combination of pig manure and cow dung presents advantages for optimal biogas production.展开更多
In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtaine...In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed power from 14913.978 kVA to 14010.100 kVA, a reduction in the transformer load rate from 99.4% to 93.4%, a reduction in reactive power called from 5481.729 kVAr to 481.729 kVAr, an increase in the active power transported by the substation from 8505.062 kW to 8962.323 kW, a reduction in the voltage drop from 4.8% to 3.9%, an increase in the power available at the secondary of the transformer station at full load from 13950 kW to 14700 kW and an annual electrical energy saving of 339943.48 kWh of electrical energy, therefore fuel savings and a reduction in CO<sub>2</sub> and SO<sub>2</sub> emissions due to this energy saving will be achieved. The installation of capacitor banks for optimization of reactive energy allowed a reduction in the current called therefore a reduction in the absorbed power: 14153.061 kVA, i.e. a reduction of 903.876 kVA. It is therefore essential that energy players are convinced of the need to install capacitors to reduce or even eliminate their reactive energy bill. This is necessarily accompanied by an investment by Electricité De Guinée by setting up active and reactive energy meters but also by implementing pricing in line with the reduction in the transfer of reactive energy in the network.展开更多
This study was carried out at the Mamou Higher Institute of Technology during the period from March 10 to April 15, 2022, with the aim of designing and testing a solar dryer with forced convection by drying potatoes. ...This study was carried out at the Mamou Higher Institute of Technology during the period from March 10 to April 15, 2022, with the aim of designing and testing a solar dryer with forced convection by drying potatoes. The dryer was designed using local materials. Its main geometric parameters are: 1) height of the drying chamber (90 cm), 2) length of the drying chamber (50 cm), 3) width of the drying chamber (43 cm), 4) surface of the racks (0.1806 m<sup>2</sup>), 5) surface of the heat accumulator (0.2537 m<sup>2</sup>). The experiment focused on the vacuum test of the dryer for two days and that of the drying of the sweet potato for three days from 8:30 a.m. to 5:30 p.m. The average vacuum test temperature values of the three environments are respectively accumulator (43°C), dryer chamber (41°C) and ambient environment (34°C). Four kilograms (4 kg) of boiled sweet potato were dried. The average temperatures in the accumulator and in the drying chamber during the three days of drying are respectively 33°C and 39°C. The final mass of the dried product is 1.2 kg, with a quantity of water extracted of 2 liters or 63% of the initial mass of the product. The average drying rate is 0.074 kg/h. The drying kinetics showed a decreasing rate in the absence of the heating period and the constant rate period.展开更多
文摘This present research work focuses on the valorization of pig droppings for production of biogas in mono digestion and co-digestion with proportions of cow dung from the urban commune of N’Zérékoré. It was carried out in December 2020 in the Physics laboratory of the University of N’Zérékoré. The anaerobic digestion process took 25 days in an almost constant ambient temperature of 25˚C. Five digesters were loaded on 12/06/2020, two of which with 1 kg of pig dung and 1 kg of cow dung both in mono-digestion. The 3 other digesters in co-digestion with different proportions of pig manure and cow dung. The substrate in each digester is diluted in 2 liters of water, with a proportion of (1/2). The main results obtained are: 1) the evolution of the temperature and pH during digestion process, 2) the average biogas productions 0.61 liters for (D1);1.20 liter for (D2);1.65 liter for (D3);1.51 liter for (D4) and 1.31 liter for (D5). The cumulative amounts of biogas are respectively: D1 (7.95 liters), D2 (15.60 liters), D3 (21.50 liters), D4 (19.65 liters) and D5 (17.05 liters). The total cumulative production is 81.75 liters at the end of the process. The originality of this research work is that the proposed model examines the relation between the daily biogas production and the variation of temperature, pH and pressure. The combustibility test showed the biogas produced during the first week was no combustible (contains less than 50% methane). Combustion started from the biogas produced from the 15th day and it is from the 20th day that a significant amount of stable yellow/blue flame was observed. The results of this study show the combination of pig manure and cow dung presents advantages for optimal biogas production.
文摘In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed power from 14913.978 kVA to 14010.100 kVA, a reduction in the transformer load rate from 99.4% to 93.4%, a reduction in reactive power called from 5481.729 kVAr to 481.729 kVAr, an increase in the active power transported by the substation from 8505.062 kW to 8962.323 kW, a reduction in the voltage drop from 4.8% to 3.9%, an increase in the power available at the secondary of the transformer station at full load from 13950 kW to 14700 kW and an annual electrical energy saving of 339943.48 kWh of electrical energy, therefore fuel savings and a reduction in CO<sub>2</sub> and SO<sub>2</sub> emissions due to this energy saving will be achieved. The installation of capacitor banks for optimization of reactive energy allowed a reduction in the current called therefore a reduction in the absorbed power: 14153.061 kVA, i.e. a reduction of 903.876 kVA. It is therefore essential that energy players are convinced of the need to install capacitors to reduce or even eliminate their reactive energy bill. This is necessarily accompanied by an investment by Electricité De Guinée by setting up active and reactive energy meters but also by implementing pricing in line with the reduction in the transfer of reactive energy in the network.
文摘This study was carried out at the Mamou Higher Institute of Technology during the period from March 10 to April 15, 2022, with the aim of designing and testing a solar dryer with forced convection by drying potatoes. The dryer was designed using local materials. Its main geometric parameters are: 1) height of the drying chamber (90 cm), 2) length of the drying chamber (50 cm), 3) width of the drying chamber (43 cm), 4) surface of the racks (0.1806 m<sup>2</sup>), 5) surface of the heat accumulator (0.2537 m<sup>2</sup>). The experiment focused on the vacuum test of the dryer for two days and that of the drying of the sweet potato for three days from 8:30 a.m. to 5:30 p.m. The average vacuum test temperature values of the three environments are respectively accumulator (43°C), dryer chamber (41°C) and ambient environment (34°C). Four kilograms (4 kg) of boiled sweet potato were dried. The average temperatures in the accumulator and in the drying chamber during the three days of drying are respectively 33°C and 39°C. The final mass of the dried product is 1.2 kg, with a quantity of water extracted of 2 liters or 63% of the initial mass of the product. The average drying rate is 0.074 kg/h. The drying kinetics showed a decreasing rate in the absence of the heating period and the constant rate period.