In this paper , a novel Magnetorheological ( MR) valve with a tunable resistance minimum 1 mm to maximum 2 mm was designed. In addition , a mathematical model of the pressure drop betweenthe inlet port and the outle...In this paper , a novel Magnetorheological ( MR) valve with a tunable resistance minimum 1 mm to maximum 2 mm was designed. In addition , a mathematical model of the pressure drop betweenthe inlet port and the outlet port for the proposed MR valve was developed. Magnetic simulation was and combined with the pressure drop calculation using the derived MR valve model. The valve geometric parameters , such as the valve body thickness , the winding groove depth and the large end of radiusof the valve sleeve on the valve performance were analyzed. The relevant results will provide the theoretical basisfor the MR valve size design and structure optimization.展开更多
基金supported by National Natural Science Foundation of China (No.51165005,51475165)
文摘In this paper , a novel Magnetorheological ( MR) valve with a tunable resistance minimum 1 mm to maximum 2 mm was designed. In addition , a mathematical model of the pressure drop betweenthe inlet port and the outlet port for the proposed MR valve was developed. Magnetic simulation was and combined with the pressure drop calculation using the derived MR valve model. The valve geometric parameters , such as the valve body thickness , the winding groove depth and the large end of radiusof the valve sleeve on the valve performance were analyzed. The relevant results will provide the theoretical basisfor the MR valve size design and structure optimization.