期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
直流电晕等离子体重整甲烷二氧化碳制取合成气的研究 被引量:5
1
作者 陈亮 鲁群苟 +2 位作者 胡辉 李浩 汪雨轩 《应用化工》 CAS CSCD 北大核心 2018年第9期1947-1951,共5页
为了探究线筒式直流电晕等离子重整CH_4和CO_2制合成气的效果,利用直流电晕放电装置对CH_4和CO_2进行了重整实验。考察了大气压下甲烷含量、放电电压和进气流量对反应物转化率、产物选择性和能量转化效率的影响。结果表明,随着进气中甲... 为了探究线筒式直流电晕等离子重整CH_4和CO_2制合成气的效果,利用直流电晕放电装置对CH_4和CO_2进行了重整实验。考察了大气压下甲烷含量、放电电压和进气流量对反应物转化率、产物选择性和能量转化效率的影响。结果表明,随着进气中甲烷含量的增大,CH_4转化率下降,CO_2转化率上升,产物选择性和能量转化效率皆先上升后下降;随着电压的增大,原料转化率和选择性皆呈上升趋势,但都存在一个极限值,能量转化效率先上升后下降;随着进气流量的增大,原料转化率和产物选择性皆下降,能量转化效率先上升后下降。整体上,线筒式直流电晕等离子体重整甲烷和二氧化碳制取合成气具有设备简单、产物选择性高和能量转化效率高的优点。 展开更多
关键词 直流电晕 等离子体 甲烷 二氧化碳 重整 合成气
下载PDF
Experimental study on toluene removal by a two-stage plasma-biofilter system 被引量:1
2
作者 Hao HUANG Lihao HE +3 位作者 Yuxuan WANG Liang CHEN Hui HU Mi ZHANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第12期139-147,共9页
Volatile organic compounds(VOCs) are typical pollutants that affect air quality.Discharge plasma is thought to be a potential method that can remove VOCs from flue gas.In this experiment,pulsed corona discharge plasma... Volatile organic compounds(VOCs) are typical pollutants that affect air quality.Discharge plasma is thought to be a potential method that can remove VOCs from flue gas.In this experiment,pulsed corona discharge plasma combined with a biological tower was carried out to remove the benzene series,and toluene was selected as the typical VOC.The results indicated that the removal efficiency of toluene by pulsed corona plasma was slightly higher than that of direct current(DC) corona plasma,while its energy efficiency was much higher than DC corona plasma.Under the optimal experimental conditions of pulse voltage 8.5 kV,initial toluene concentration 1400 mg m^(-3),and toluene flow rate of 121h^(-1),the toluene removal efficiency reached 77.11% by the single method of pulsed corona discharge plasma,and the energy efficiency was up to 1.515 g/(kW·h) under the pulse voltage of 4.0 kV.The trickling biofilter was constructed by using the screened and domesticated Acinetobacter baumannii,and the highest toluene removal efficiency by the pulsed corona discharge plasma combined with the trickling biofilter rose up to 97.84%.Part of the toluene was degraded into CO_(2),H_(2)O,and some intermediate products such as o-diphenol under the influence of Acinetobacter baumannii.When the remaining waste gas passed through the discharge plasma reactor,the benzene ring structure could be directly destroyed by the collision between toluene and plasma.Meanwhile,O·,OH·,and some other oxidizing radicals generated by the discharge also join into the oxidative decomposition of toluene and its intermediate products,thereby further improving the removal efficiency of toluene.Therefore,the two-stage plasma-biofilter system not only showed a high toluene removal efficiency,but also had a good energy efficiency.The results of this study will provide theoretical support and technical reference for industrial VOC treatment. 展开更多
关键词 pulsed corona discharge VOCs purification trickling biofilter combined removal
下载PDF
脉冲放电等离子体处理含甲苯废气的实验研究
3
作者 李浩 《应用能源技术》 2019年第1期48-50,共3页
采用脉冲电晕放电等离子体技术,建立了一套等离子体降解VOCs的装置,选取甲苯为代表物质进行实验研究,考察放电电压、含甲苯废气流量、甲苯初始浓度对甲苯降解率的影响。结果表明,当放电电压为11. 5 kV,气流速率为12 L/h,甲苯初始浓度为5... 采用脉冲电晕放电等离子体技术,建立了一套等离子体降解VOCs的装置,选取甲苯为代表物质进行实验研究,考察放电电压、含甲苯废气流量、甲苯初始浓度对甲苯降解率的影响。结果表明,当放电电压为11. 5 kV,气流速率为12 L/h,甲苯初始浓度为500. 0 mg/m3时,甲苯去除率为85. 6%,脉冲电晕等离子体处理低浓度有机废气效果更好。 展开更多
关键词 VOCS 脉冲电晕 等离子体甲苯去除率
下载PDF
上一页 1 下一页 到第