Three large sized glass resistive plate chambers (RPCs) are built and applied to measure the spatial resolution of the detector. The readout strips are collected to a LC delay-line and the time difference is used to...Three large sized glass resistive plate chambers (RPCs) are built and applied to measure the spatial resolution of the detector. The readout strips are collected to a LC delay-line and the time difference is used to determine the position. Cosmic rays are triggered by a set of two scintillation counters and the coincidently measured positions from the three RPCs are used to deduce the position uncertainty. In average a spatial resolution of 0.90 mm (FWHM) is obtained for a single RPC, with a good uniformity across the detection area. This result suggests that large sized glass RPC operating in the avalanche mode is a promising candidate for the muon tomography detection system.展开更多
A laser phase determination method and a transfer function that includes a proportional term of a measured photoelectron energy spectrum are presented to directly measure the detailed temporal structure of a narrow ba...A laser phase determination method and a transfer function that includes a proportional term of a measured photoelectron energy spectrum are presented to directly measure the detailed temporal structure of a narrow bandwidth attosecond extreme-ultraviolet (EUV) pulse. The method is based on the spectrum measurement of an electron generated by EUV photo-ionization interacting with a femtosecond laser field. The results of the study suggest that measurements should be taken at 0° or 180° with respect to the linear laser polarization. The method has a temporal measurement range of about half a laser oscillation period. The temporal resolution also depends on the jitter and control precision of the laser and EUV pulses.展开更多
The carrler-envelope-phase (CEP) dependence of the emission properties of high-order harmonic generation (HHG) are quantitatively investigated. Calculation shows that a two-cycle laser with CEP of 15° can pro...The carrler-envelope-phase (CEP) dependence of the emission properties of high-order harmonic generation (HHG) are quantitatively investigated. Calculation shows that a two-cycle laser with CEP of 15° can produce a single energy distribution pulse peaked at 0.94 radian (tad) and spanned 1.29 tad with the cutoff energy 2.9Up + Ip and a bandwidth 0.86Up (where Up is the ponderomotive potential of the laser field and Ip is the atomic ionization potential). The CEP dependence of the energy and temporal localizations of the single distribution pulse show interesting 180° periodic structures. These characteristics may be useful in optimizing attosecond x-ray sources and measurements.展开更多
Laser phase relations of high-order harmonic generation (HHG) are calculated with the saddle point theory. The results show a two-peak structure including a symmetric and an asymmetric temporal distributions of the ...Laser phase relations of high-order harmonic generation (HHG) are calculated with the saddle point theory. The results show a two-peak structure including a symmetric and an asymmetric temporal distributions of the instantaneous frequency of HHG radiation. These distributions are fitted with Gaussian and polynomial functions, respectively. Two calculation formulae are presented to analyse attosecond x-rays with specified time duration and energy bandwidth in experiments.展开更多
To perform a kinematically complete measurement of the dissociation reaction for neutron-rich nuclei, a multi-neutron correlation spectrometer is proposed at Peking University. A Monte Carlo simulation code based on G...To perform a kinematically complete measurement of the dissociation reaction for neutron-rich nuclei, a multi-neutron correlation spectrometer is proposed at Peking University. A Monte Carlo simulation code based on GEANT4 is developed for a single scintillation bar which processes not only the energy deposition but also the light propagation in the scintillator and the light collection and conversion to signal at the end of the bar in a realistic way. The simulating method is described in detail in this paper, and the timing and position resolutions and detector efficiency are studied based on the simulation and compared with the experimental results. A new method of crosstalk rejection has been demonstrated to be important for the design of the whole spectrometer.展开更多
基金Supported by National Natural Science Foundation of China(11035001, 10827505, 10775003)
文摘Three large sized glass resistive plate chambers (RPCs) are built and applied to measure the spatial resolution of the detector. The readout strips are collected to a LC delay-line and the time difference is used to determine the position. Cosmic rays are triggered by a set of two scintillation counters and the coincidently measured positions from the three RPCs are used to deduce the position uncertainty. In average a spatial resolution of 0.90 mm (FWHM) is obtained for a single RPC, with a good uniformity across the detection area. This result suggests that large sized glass RPC operating in the avalanche mode is a promising candidate for the muon tomography detection system.
文摘A laser phase determination method and a transfer function that includes a proportional term of a measured photoelectron energy spectrum are presented to directly measure the detailed temporal structure of a narrow bandwidth attosecond extreme-ultraviolet (EUV) pulse. The method is based on the spectrum measurement of an electron generated by EUV photo-ionization interacting with a femtosecond laser field. The results of the study suggest that measurements should be taken at 0° or 180° with respect to the linear laser polarization. The method has a temporal measurement range of about half a laser oscillation period. The temporal resolution also depends on the jitter and control precision of the laser and EUV pulses.
基金Supported by the National Natural Science Foundation of China under Grant No 10675014.
文摘The carrler-envelope-phase (CEP) dependence of the emission properties of high-order harmonic generation (HHG) are quantitatively investigated. Calculation shows that a two-cycle laser with CEP of 15° can produce a single energy distribution pulse peaked at 0.94 radian (tad) and spanned 1.29 tad with the cutoff energy 2.9Up + Ip and a bandwidth 0.86Up (where Up is the ponderomotive potential of the laser field and Ip is the atomic ionization potential). The CEP dependence of the energy and temporal localizations of the single distribution pulse show interesting 180° periodic structures. These characteristics may be useful in optimizing attosecond x-ray sources and measurements.
文摘Laser phase relations of high-order harmonic generation (HHG) are calculated with the saddle point theory. The results show a two-peak structure including a symmetric and an asymmetric temporal distributions of the instantaneous frequency of HHG radiation. These distributions are fitted with Gaussian and polynomial functions, respectively. Two calculation formulae are presented to analyse attosecond x-rays with specified time duration and energy bandwidth in experiments.
基金Supported by National Basic Research Program (973 Program) of China (2007CB815002)National Natural Science Founda-tion of China (10827505, 10775003, 10475004, 10405001, J0730316)
文摘To perform a kinematically complete measurement of the dissociation reaction for neutron-rich nuclei, a multi-neutron correlation spectrometer is proposed at Peking University. A Monte Carlo simulation code based on GEANT4 is developed for a single scintillation bar which processes not only the energy deposition but also the light propagation in the scintillator and the light collection and conversion to signal at the end of the bar in a realistic way. The simulating method is described in detail in this paper, and the timing and position resolutions and detector efficiency are studied based on the simulation and compared with the experimental results. A new method of crosstalk rejection has been demonstrated to be important for the design of the whole spectrometer.